TRMS clamp meter for AC 400A current HT3010 current clamp can measure AC current up to 400A and AC/DC voltage up to 600V, resistance, continuity and diode test. The instrument provides visual (LED) and audible (buzzer) indication of presence of AC voltage thanks to a non-contact internal detector. Complying with IEC / EN 61010-1, HT3010 is ideal for measurements in both domestic and industrial environments.

Datenblatt

TRMS clamp meter for AC/DC 400A current HT3013 current clamp can measure AC/DC current up to 400A and AC/DC voltage up to 600V, resistance, frequency, capacitance, duty cycle, temperature by means of type K probes, continuity and diode test. The instrument provides visual (LED) and audible (buzzer) indication of presence of AC voltage thanks to a non-contact internal detector. Complying with IEC / EN 61010-1, HT3013 is ideal for measurements in both domestic and industrial environments.

Datenblatt

  • Measuring range: 1A ÷ 400A
  • Basic accuracy: ±1.5%reading+ 0.5A
  • Measurement category: CAT III 600V
  • Clamp jaw internal diameter: 30mm
  • Output connector: 2x banana connector
Datenblatt

  • Ranges: 10A / 100A
  • Basic accuracy: ±1.0%reading
  • Measurement category: CAT III 600V
  • Clamp jaw internal diameter: 32mm
  • Output connector: Hypertac
Datasheet
User Manual

  • Zange für AC/DC 10/100A
  • Messbereich: 0.01A – 100A
  • Präzision DC: ±1.0%Ablesung +3mA
  • Präzision AC: ±1.0%Ablesung +3mA
  • Ausgangssignal: 1VAC/DC
  • Überspannungskategorie: CAT III 300V
  • Max. Kabeldurchmesser: 32mm
  • Anschluss: Hypertac Stecker mit externer Spannungsversorgung zum Anschluss an das MPP300
Datenblatt
Bedienungsanleitung

  • Measuring range: 0.1÷200A
  • Basic accuracy: ±0.5%reading
  • Measurement category: CAT III 600V
  • Clamp jaw internal diameter: 40mm
  • Output connector: Hypertac
Datasheet

Clamp meter HT4011 has been designed to measure AC current up to 400A and AC/DC voltage up to 600V to reach CAT III 600V in compliance with standard IEC/EN61010- 1. The clamp is provided with an internal sensor to detect AC voltage also without contact, through a red LED turning on. HT4011 also carries out measurements of Resistance, Continuity tests, Frequency, Capacity, Diode test, Duty Cycle and Temperature with K-type probe, among others. The clamp is also provided with the auto power off function to preserve its own battery.

Datasheet
User Manual

Clamp meter HT4013 has been designed to measure AC/ DC current up to 400A and AC/DC voltage up to 600V to reach CAT III 600V in compliance with standard IEC/ EN61010-1. The clamp is provided with an internal sensor to detect AC voltage also without contact, through a red LED turning on. This model also carries out measurements of Resistance, Continuity tests, Frequency, Capacity, Diode test, Duty Cycle and Temperature with K-type probe, among others. The clamp is also provided with the auto power off function to preserve its own battery.

Datenblatt
Bedienungsanleitung

HT4022 carry out measurements in TRMS of AC current up to 400A, AC/DC voltage up to 600V, Frequency, Resistance, Continuity test, Active, Reactive, Apparent Power, Cos , Energy for balanced single-phase and/or three-phase systems, further to the detection of phase sequence by 1-terminal method. Model HT4022 also carries out the absolute/percentage measurement of voltage and current harmonic components with calculation of THD%. Each device complies with IEC/EN61010-1 in CAT III 600V and is the ideal solution or troubleshooting typical problems in industrial environments such as non-linear loads, frequencycontrolled motors.

Datenblatt
Bedienungsanleitung

Clamp meter HT7004 is capable of measuring TRMS AC current up to 300A in Autorange, in compliance with IEC/EN61010-1, CAT III 300V. It is featured by Data HOLD, AC voltage measurement without contact, backlighting and auto power off to save internal battery. Thanks to its compact size it is suitable to effect simple measurements on both civil and industrial standard installations.

Datasheet
User Manual

AC Clamp meter for leakage current from 10µA to 60A New model HT77C is clamp meters designed for an accurate measurement of very low values of AC currents and, therefore, they are mainly employed in detecting and and defining leakage currents in private and industrial electric systems, which typically cause RCDs’ tripping. Clamp meters are provided, among others, with an integrated lowpass filter to eliminate harmonic components.

Datasheet
User Manual

AC/DC leakage current clamp meter The HT79 clamp is designed primarily for the measurement of AC and DC leakage currents and measurement of currents up to 10A (DC) and 20A (AC) in reaching CAT IV 300V according to IEC / EN61010-1. Other measures envisaged are the AC / DC Voltage, Resistance and Continuity Test measurement. The instrument has a 5000-point display, display backlight, auto-off function to preserve its internal battery. HT79 can clamp a conductor with a maximum size of 23mm. Other important functions present are the MIN / MAX for the detection of the Maximum and Minimum value of the quantities, the Data HOLD function and the ZERO function for the execution of preliminary zeroing of the currents.

Datenblatt
Bedienungsanleitung

Professional clamp meter AC 600A TRMS, CAT IV 600V Professional clamp meter HT9012 has been designed to measure AC current up to 600A and AC/DC voltage up to 1000V to reach CAT IV 600V and CAT III 1000V in compliance with standard IEC/ EN61010-1. The clamp is provided with a wide backlit display with 6000 measuring spots and an auto power off function to preserve its battery.

Datasheet
User Manual

Professional clamp meter AC 600A TRMS, CAT IV 600V Professional clamp meter HT9014 has been designed to measure AC current up to 600A and AC/DC voltage up to 1000V TRMS to reach CAT IV 600V and CAT III 1000V in compliance with standard IEC/ EN61010-1. The clamp is provided with a wide backlit display with 6000 measuring spots and an auto power off function to preserve its battery.

Datenblatt
Bedienungsanleitung

AC/DC TRMS 600A CAT IV clamp meter with temperature measurement HT9015 has been designed to measure AC/DC current up to 600A and AC/DC voltage up to 1000V in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/EN61010-1. The clamp is provided with a display with 6000 measuring spots with backlight and bargraph to allow for a simple reading even in poorly lit environments. HT9015 also measures Resistance, Frequency, Capacity and Temperature with K-type probe.

Datenblatt
Bedienungsanleitung

Professional clamp meters AC 1000A TRMS, CAT IV 600V Professional clamp meter HT9019 has been designed to measure AC current up to 1000A and AC/DC voltage up to 1000V in TRMS to reach CAT IV 600V according to standard IEC/ EN61010-1. The clamp is provided with a wide display with 6000 measuring spots, backlight and analogue bargraph to allow for a simple reading even in poorly lit environments. Clamp HT9019 is also provided with the auto power off function to preserve its own battery.

Datasheet
User Manual

Clamp-on power quality analyzer HT9020 has been designed for measuring DC, AC+DC TRMS current up to 1000A according to CAT IV 600V in compliance with standard IEC/EN61010-1 HT9020 carries out measurements of Active, Reactive and Apparent Power and Energy, voltage and current harmonic analysis up to the 25th order with THD% calculation, in single-phase or three-phase balanced systems. It also tests phase sequence and phase conformity by 1-lead measuring method as well as detects any event related to electric motor starting currents (DYNAMIC INRUSH). DYNAMIC INRUSH™ permits to measure inrush currents with user-defined time frames, providing measurements more reliable than standard fixed time-frame testers. The user has the chance to recall and display the measurement by applying different time frames. For example, if the user carries out a measurement using a time frame of 100 ms, he can post-process the same measurement by applying a time frame of: 16,7, 20, 50, 100, 150, or 200 ms. This grants the utmost flexibility for each measurement, and prevents to measure again and again to get the real inrush current value. HT9020 is provided with traceable calibration certificate.

Datenblatt
Bedienungsanleitung

AC/DC TRMS CAT IV 600V clamp meter with temperature measurement HT9021 has been designed to measure AC/DC current up to 1000A in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/EN61010- 1. The clamp is provided with a display with 6000 measuring spots with backlight and bargraph to allow for a simple reading even in poorly lit environments. HT9021 also carries out measurements o voltage up to 1000V, Resistance, Frequency, Capacity and Temperature with K-type probe.

Datasheet
User Manual

HT9023 has been designed to measure AC, DC AC+DC current up to 1000A in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/EN61010-1. The clamp also measures DC voltage up to 1500V, AC, AC+DC voltage up to 1000V, Active, Reactive and Apparent Power, Power Factor, Energy, voltage/current harmonic analysis up to the 25th with THD% calculation in balanced single-phase or three-phase systems. It is also possible to carry out the phase sequence test with 1-terminal. The instrument also detects the events linked to motor starting currents (Dynamic INRUSH) and allows recording each measured electric parameter over time, with the possibility of transferring data via WiFi to Android/iOS devices through the HTAnalysis App (available from late 2020) or onto PC through the TOPVIEW software. The clamp is provided with a wide graphic dot-matrix screen (128x128pxl) with backlight, in order to allow reading data even in poorly lit environments, and it is provided with an auto power off function to preserve its internal battery.

Datasheet
User Manual

HT9025 has been designed to measure AC/DC current up to 1000A, DC voltage up to 1500V and AC voltage up to 1000V in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/ EN61010-1. The clamp is provided with a display with 6000 measuring spots with backlight and bargraph to allow for a simple reading even in poorly lit environments. HT9025 also measures Resistance, Frequency, Capacity and Temperature with K-type probe.

Datasheet
User Manual

  • Current: 2,000 A AC / 3,000 A DC
  • Voltage: 1,000 V AC/DC
  • Clamping diameter: 60 mm
  • Large 10,000-count display
  • Automatic AC / DC detection
  • Min, Max, Peak
  • RELative and differential measurements
  • Power values
  • THD & Harmonics
Datasheet

The F201 clamp is ideal for the needs of both self-employed electricians and SME contractors in the electrical sector.

Datasheet

The F203 clamp is ideal for the needs of both self-employed electricians and SME contractors in the electrical sector.

Datasheet

The F205 clamp is ideal for low and medium-power Low-Voltage applications, maintenance of tertiary or industrial electrical installations and troubleshooting and sizing of electrical power supplies.

Datasheet

  • Clamping diameter: 48 mm
  • Current: 1,000 A AC
  • Voltage up to 1,200 VAC / 1,700 VDC
  • Resistance and audible continuity
  • Temperature
  • Automatic AC/DC detection
  • TrueInrush current measurement
  • Hold, Min, MAX
  • CAT IV 1,000 V / CAT III 1,500 V
  • IP54 protection rating
Datasheet
User Manual

  • Clamping diameter: 48 mm
  • Current: 1,000 A AC / 1,500 A DC
  • Voltage up to 1,200 VAC / 1,700 VDC
  • Resistance and audible continuity
  • Temperature
  • Automatic AC/DC detection
  • TrueInrush current measurement
  • Hold, Min, MAX
  • RELative (ΔX) and differential (ΔX/X) measurements
  • Adapter function
  • Adapter function
  • CAT IV 1,000 V / CAT III 1,500 V
  • IP54 protection rating
Datenblatt
Bedienungsanleitung

  • Clamping diameter: 48 mm
  • Current: 1,000 A AC / 1,500 ADC
  • Voltage up to 1,200 VAC / 1,700 VDC
  • Resistance and audible continuity
  • Power values (W, var, VA, PF) and Harmonic Distortion (THDf, THDr)
  • "2-wire" phase rotation
  • RELative (ΔX) and Differential measurements (ΔX/X)
  • Diod test
  • Automatic AC/DC detection
  • TrueInrush current measurement
  • Hold, Min, MAX, Peak+ / Peak-
  • CAT IV 1,000 V / CAT III 1,500 V
  • IP54 protection rating
Datasheet
User Manual

  • AC and DC measurements
  • Measurements of power and energy values
  • Decomposition of harmonic orders
  • Measurement recorder
Datasheet

  • Clamping diameter: 60 mm
  • Current: 2,000 A AC / 3,000 A DC
  • Voltage up to 1,200 AAC et 1,700 ADC
  • Resistance and audible continuity
  • Temperature
  • Automatic AC/DC detection
  • TrueInrush current measurement
  • Hold, Min, MAX
  • RELative (ΔX) and differential (ΔX/X) measurements
  • Adapter function
  • CAT IV 1,000 V / CAT III 1,500 V
  • IP54 protection rating
Datasheet
User Manual

  • Clamping diameter: 60 mm
  • Current: 2,000 A AC / 3,000 A DC
  • Voltage up to 1,200 VAC / 1,700 VDC
  • Resistance and audible continuity
  • Power values (W, var, VA, PF) and harmonics (THDf, THDr)
  • "2-wire method" phase rotation
  • Automatic AC/DC detection
  • TrueInrush current measurement
  • Min, MAX, Peak+, Peak-
  • RELative (ΔX) and differential (ΔX/X) measurements
  • CAT IV 1,000 V / CAT III 1,500 V
  • IP54 protection rating
Datasheet
User Manual

  • AC and DC measurements
  • Power and energy measurements
  • Decomposition of harmonic orders
  • Measurement recorder
Datasheet

To deal with the highest level of low-voltage electrical installations, the F400 Series has a high protection rating and is ideal for maintenance, testing, monitoring and diagnostics on medium-power installations.

Datasheet

To deal with the highest level of low-voltage electrical installations, the F400 Series has a high protection rating and is ideal for maintenance, testing, monitoring and diagnostics on medium-power installations.

Datasheet

To deal with the highest level of low-voltage electrical installations, the F400 Series has a high protection rating and is ideal for maintenance, testing, monitoring and diagnostics on medium-power installations.

Datasheet

With protection against electric shocks up to 12 kV, the F600 Series fulfils the most demanding safety criteria (CAT IV 1,000 V) and offers a high protection rating allowing users to work in total safety on all LV installations. The F600 Series is ideal for high-power applications such as electrical power distribution, chemical and petrochemical industries, metallurgy, rail transport, etc.

Datasheet

With protection against electric shocks up to 12 kV, the F600 Series fulfils the most demanding safety criteria (CAT IV 1,000 V) and offers a high protection rating allowing users to work in total safety on all LV installations.

Datasheet

Clamp meter HT4011 has been designed to measure AC current up to 400A and AC/DC voltage up to 600V to reach CAT III 600V in compliance with standard IEC/EN61010- 1. The clamp is provided with an internal sensor to detect AC voltage also without contact, through a red LED turning on. HT4011 also carries out measurements of Resistance, Continuity tests, Frequency, Capacity, Diode test, Duty Cycle and Temperature with K-type probe, among others. The clamp is also provided with the auto power off function to preserve its own battery.

Datasheet

Clamp meter HT4013 has been designed to measure AC/ DC current up to 400A and AC/DC voltage up to 600V to reach CAT III 600V in compliance with standard IEC/ EN61010-1. The clamp is provided with an internal sensor to detect AC voltage also without contact, through a red LED turning on. This model also carries out measurements of Resistance, Continuity tests, Frequency, Capacity, Diode test, Duty Cycle and Temperature with K-type probe, among others. The clamp is also provided with the auto power off function to preserve its own battery.

Datasheet

Clamp meter HT7003 can carry out measurements of AC current up to 200A in Autorange, in compliance with IEC/EN61010-1, CAT III 300V. It is provided with Data HOLD function and is provided with auto power off function in order to preserve the internal battery when not in use. Thanks to its extremely small size, this model is very practical and it is the ideal solution for simple measurements in the most common private and industrial environments.

Datasheet

Professional clamp meter HT9012 has been designed to measure AC current up to 600A and AC/DC voltage up to 1000V to reach CAT IV 600V and CAT III 1000V in compliance with standard IEC/ EN61010-1. The clamp is provided with a wide backlit display with 6000 measuring spots and an auto power off function to preserve its battery.

Datasheet

Professional clamp meter HT9014 has been designed to measure AC current up to 600A and AC/DC voltage up to 1000V TRMS to reach CAT IV 600V and CAT III 1000V in compliance with standard IEC/ EN61010-1. The clamp is provided with a wide backlit display with 6000 measuring spots and an auto power off function to preserve its battery.

Datasheet

AC/DC TRMS 600A CAT IV clamp meter with temperature measurement HT9015 has been designed to measure AC/DC current up to 600A and AC/DC voltage up to 1000V in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/EN61010-1. The clamp is provided with a display with 6000 measuring spots with backlight and bargraph to allow for a simple reading even in poorly lit environments. HT9015 also measures Resistance, Frequency, Capacity and Temperature with K-type probe.

Datasheet

Professional clamp meters AC 1000A TRMS, CAT IV 600V Professional clamp meter HT9019 has been designed to measure AC current up to 1000A and AC/DC voltage up to 1000V in TRMS to reach CAT IV 600V according to standard IEC/ EN61010-1. The clamp is provided with a wide display with 6000 measuring spots, backlight and analogue bargraph to allow for a simple reading even in poorly lit environments. Clamp HT9019 is also provided with the auto power off function to preserve its own battery.

Datasheet

HT9021 has been designed to measure AC/DC current up to 1000A in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/EN61010- 1. The clamp is provided with a display with 6000 measuring spots with backlight and bargraph to allow for a simple reading even in poorly lit environments. HT9021 also carries out measurements o voltage up to 1000V, Resistance, Frequency, Capacity and Temperature with K-type probe.

Datasheet

Specifications:

  • 6,000-count display
  • Acquisition: TRMS
  • Clamping diameter: 26 mm
  • AC current: 60.00 A / 400.0A
  • AC voltage: 60.00 V / 600.0 V
  • DC voltage: 60.0.0 V / 600.0 V
  • Resistance: 600.0 Ω
  • Audible continuity test, diode test
  • Functions: HOLD (freezes the display),
  • IEC/EN 61010 CAT III 600V safety
Datasheet

  • 6,000-count display
  • Acquisition: True Root Mean Square (TRMS)
  • Clamping diameter: 30mm
  • AC current: 60.00 A / 400.0A
  • DC current: 60.00 A / 400.0 A
  • AC voltage: 60.00 V / 600.0 V
  • DC voltage: 60.0.0 V / 600.0 V
  • Resistance: 600.0 Ω
  • Audible continuity test, diode test
  • Functions: HOLD (freezes the display), Peak (peak value)
  • Automatic ZERODC/Relative measurement.
  • Safety: IEC/EN 61010 CAT III 600V
Datasheet

MX650 specifications:

  • 4,000-count display
  • 42-segment bargraph
  • Clamping diameter: 40 mm
  • AC current: 0.05 A to 1,000 A
  • AC voltage: 0.5 V to 750 V
  • DC voltage: 0.2 V to 1,000 V
  • Resistance: 0.2 Ω to 4 kΩ
  • Frequency: 10 Hz to 4 kHz (A) / 10 kHz (V)
  • Audible continuity test & diode test
  • Safety: EN 61010 CAT III 600 V
  • Functions:
    •   HOLD
    •   PEAK (capture of 1ms signals)
    •   MIN-MAX
    •   REL (relative measurements)
Datasheet

MX655, specifications:

  • 4,000-count display
  • 42-segment bargraph
  • Clamping diameter: 40 mm
  • AC current: 0.05 A to 1,000 A RMS
  • DC current: 0.1 A to 1,000 A
  • AC voltage: 0.5 V to 750 V
  • DC voltage: 0.2 V to 1,000 V
  • Resistance: 0.2 Ω to 4 kΩ
  • Frequency: 20 Hz to 10 kHz (A) / 10 Hz to 10 kHz (V)
  • Audible continuity test & diode test
  • Safety: EN 61010 CAT III 600 V
  • Functions:
    • HOLD
    • PEAK (capture of 1 ms signals)
    • MIN-MAX
    • REL (relative measurements)
Datasheet

MX670, specifications:

  • 10,000-count backlit display
  • Clamping diameter: 42 mm
  • AC current: 0.05 A to 1,000 A
  • DC voltage: 0.2 A to 1,400 V
  • AC voltage: 0.5 V to 1,000 V
  • Resistance: 0.2 Ω to 10 kΩ
  • Frequency: up to 10 kHz (A and V)
  • Temperature: -40.0°C to 1,200 °C (K thermocouple)
  • Diode test and audible continuity
  • HOLD, MIN, MAX and Peak functions
  • 600 V CAT IV
Datasheet

MX375 specifications:

  • 10,000-count backlit display
  • Clamping diameter: 40 mm
  • DC current: 0.05 A to 1,400 A
  • AC current: 0.05 A to 1,000 A
  • DC voltage: 0.2 A to 1,400 V
  • AC voltage: 0.5 V to 1,000 V
  • Resistance: 0.2 Ω to 10 kΩ
  • Frequency: up to 10 kHz (A and V)
  • Temperature: -40.0°C to 1,200 °C (K thermocouple)
  • Diode test and audible continuity test
  • HOLD, MIN, MAX, Peak and ΔZero functions
  • 600 V CAT IV
Datasheet

Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.