Showing all 27 results

1 kV Insulation and Continuity Tester Industrial maintenance 40 GΩ / Test voltage 250-500-1,000 V Manual / Lock / Duration modes Continuity, Voltage

Datasheet

1 kV Insulation and Continuity Tester Industrial maintenance 200 GΩ Test voltage: 50-100-250-500-1 000 V Manual / Lock / Duration modes, PI / DAR ratios Alarms, ∆REL

Datasheet

1 kV Insulation and Continuity Tester Industrial maintenance 200 GΩ Test voltage: 50-100-250-500-1,000 V Manual / Lock / Duration modes, PI / DAR ratios Continuity, Voltage, Capacitance Alarms, ∆REL

Datasheet

  • Voltage: 0 to 700 VAC/DC
  • Insulation: up to 11 GΩ
  • Continuity: 0.02 Ω to 40 Ω
  • Resistance: 1 Ω to 420 kΩ
  • Automatic voltage detection
  • Compliant with IEC 61557-1-2-4-10
  • Electrical safety: IEC 61010-1, 61010-2-030, 61010-2-034 - 600V CAT IV
  • IP40
Datasheet
User Manual

  • Communicating 50-100 V Telecom Insulation and Continuity Tester
  • 20 GΩ, Test voltage: 50-100 V
  • Continuity, Voltage, Frequency, Capacitance
  • Distance = f(C)
  • Storage, Communication
Datasheet

  • Communicating Insulation and Continuity Tester for Electronics Applications
  • 50 GΩ
  • Test voltage : 10-25-100-250-500 V
  • Manual / Lock / Duration modes
  • Alarms, ∆REL
  • Continuity, Voltage
  • Storage, Communication
Datasheet

  • Insulation and Continuity Tester for Special Applications
  • 20 GΩ
  • Test voltage : 10 to 100 V - 1 V increments
  • Manual / Lock / Duration modes
  • Alarms, ∆REL
  • Continuity, Voltage, Resistance
  • Magnetic mounting
Datasheet

  • Fixed 500/1,000/2,500/5,000 V DC test voltage or programmable from 40 V to 5,100 V DC
  • Measurement range: 10 kΩ to 10 TΩ
  • Programmable test duration
  • Calculation of DAR & PI quality ratios
  • Measurement of voltage, capacitance and leakage current
  • LCD screen with bargraph
  • Power supply by NiMh rechargeable battery
  • Compliant with IEC 61557
  • IP53 protection
  • IEC 61010 1,000 V CAT III safety
  • Dimensions: 270 x 250 x 180 mm / 4.3 kg
Datasheet

  • insulation: up to 4 TΩ (5 cal.) at 50/100/250/500 and 1,000 V DC
  • automatic calculation of insulation quality ratios: DAR and PI
  • programmable test duration and plotting of the R(t) curve (automatic storage of 20 samples)
  • automatic indication of voltage before and after measurement: 1 to 1,000 V AC/DC
  • resistance: 0.01 Ω to 400 kΩ
  • continuity: 0.01Ω to +40 Ω (audible beep and lead compensation)
  • automatic measurement capacity after each insulation measurement: 0.005 to 4.999 µF
  • microprocessor-controlled
  • large LCD screen with digital display + bargraph
  • backlighting
  • SMOOTH function
  • insulation test voltages can be locked
  • programmable alarms
  • long battery life: 8 x LR14 batteries (21,000 insulation tests of 5s each)
  • remote control probe available as an option
  • electrical safety: IEC 61010 600V CAT III  and IEC 61557
  • dimensions: 240 x 185 x 110mm; weight: 3.4 kg
Datasheet

  • insulation: up to 4 TΩ (5 ranges) at 50/100/250/500 and 1,000 V DC
  • automatic calculation of insulation quality ratios: DAR and PI
  • programmable test duration and plotting of the R(t) curve
  • automatic indication of voltage before and after measurement: 1 to 1,000 V AC/DC
  • resistance: 0.01Ω to 400 kΩ
  • continuity: 0.01 Ω to +40 Ω (audible beep and cable compensation)
  • automatic capacitance measurement after each insulation measurement: 0.005 to 4.999 µF
  • microprocessor-controlled
  • storage of measurements (128 kB)
  • bi-driectional RS232
  • large LCD screen with digital display and bargraph
  • backlighting
  • SMOOTH function
  • possibility of locking insulation test voltages
  • programmable alarms
  • long battery life thanks to rechargeable battery with internal charger
  • remote control probe available as an option
  • electrical safety: IEC 61010 600V CAT III and IEC 61557
  • dimensions: 240 x 185 x 110mm; weight: 3.4kg
  • large number of optional accessories: remote control probe, MegohmView PC data processing software, printer
Datasheet

  • measurement range: 10 kΩ to 10 TΩ
  • 4 fixed test voltages: 500 / 1,000 / 2,500 and 5,000 V
  • adjustable test voltage position: 40 to 5,100 V in 10 V or 100 V increments
  • large backlit LCD screen with digital display and bargraph
  • quantitative insulation analysis: DAR, PI and DD (dielectric discharge) quality ratios calculated automatically and R(t) stored
  • large number of functions: programmable test duration, test voltage locking, smooth function, programmable alarms, etc.
  • power supply: NiMH rechargeable battery for 30 days' operation with 10 DAR measurements and 5 PI measurements per day
  • electrical safety: IEC 61010-1 Cat.III 1000V or Cat.I 2500V and IEC 61557
  • dimensions: 270 x 250 x 180 mm; weight: 4.3 kg
Datasheet

Functions and specifications:

  • measurement range: 10 kΩ to 10 TΩ
  • 4 fixed test voltages: 500 / 1,000 / 2,500 and 5,000 V
  • adjustable test voltage position: 40 to 5,100 V in 10 V or 100 V increments
  • large backlit LCD screen with digital display and bargraph
  • quantitative insulation analysis: DAR, PI and DD (dielectric discharge) quality ratios calculated automatically and R(t) curve plotted
  • large number of functions: programmable test duration, test voltage locking, smooth function, programmable alarms, etc.
  • storage of several thousand measurements
  • RS 232 connector for connection to PC (Megohmeter data processing software) or very compact serial printer
  • power supply: NiMH rechargeable battery for 30 days' operation with 10 DAR measurements and 5 PI measurements per day
  • electrical safety: IEC 61010-1 Cat.III 1000V or Cat.I 2500V and IEC 61557
  • dimensions: 270 x 250 x 180 mm; weight: 4.3 kg
Datasheet

  • measurement range: 10 kΩ to 10 TΩ
  • 4 fixed test voltages: 500 / 1,000 / 2,500 and 5,000V
  • adjustable test voltage position: 40 to 5,100V in 10V or 100V increments
  • step voltage mode: R(Utest) measurement curve viewed on the screen and gradient calculated automatically in ppm/V
  • DAR, PI and DD quality ratios calculated automatically
  • programmable test length and R(t) measurement curve displayed directly on the screen
  • after measurement with indication of measurement temperature, resistance recalculated at reference temperature for reliable and accurate insulation monitoring
  • many other functions: test voltage locking, smooth function, programmable alarms, etc.
  • storage of several thousand measurements
  • RS 232 connector for connection to PC or very compact serial printer
  • power supply: NiMH rechargeable battery for 30 days' operation with 10 DAR measurements and 5 PI measurements per day
  • electrical safety: IEC 61010-1 Cat.III 1000V or Cat.I 2500V and 61557
  • dimensions: 270 x 250 x 180 mm; weight: 4.3 kg
Datasheet

  • Wide measurement range from 10 kohm to 25 Tohm
  • Fixed or programmable test voltage from 40V to 10 kV
  • 5mA max charging current
  • Large backlit LCD screen with digital display, bargraph and R(t)+u(t), i(t) and i(u) graphs
  • Automatic ratio calculation: DAR / PI / DD / DR (ppm/V)
  • Multiple test modes: voltage ramp and step with "burning", "early break" and "I-limit" modes
  • 3 filters to optimize measurement stability
  • Calculation of R at a reference temperature
  • 80,000-measurement storage capacity and real-time clock
  • Optically-isolated USB communication for transfer onto PC and report generation with DataView® software
Datasheet

  • Wide measurement range from 10 kΩ to 25 TΩ
  • Fixed or programmable test voltage from 40V to 15 kV
  • 5mA max. charging current
  • Large backlit LCD screen with digital display, bargraph and R(t)+u(t), i(t) and i(u) graphs
  • Automatic ratio calculation: DAR / PI / DD / DR (ppm/V)
  • Multiple test modes: voltage ramp and step with "burning", "early break" and "I-limit" modes
  • 3 filters to optimize measurement stability
  • Calculation of R at a reference temperature
  • 80,000-measurement storage capacity and real-time clock
  • Optically-isolated USB communication for transfer onto PC and report generation with DataView® software
  • Power supply NiMH rechargeable battery with external charger
  • Compliant with IEC 61557 -1 -2
  • Electrical safety: IEC 61010 1000V CAT IV
  • Dimensions: 406 x 330 x 174 mm / 6 kg
Datasheet

  • Test voltage: 500 V DC
  • Measurement range: 0.5 to 200 MΩ
  • Resistance measurement: 45 to 500 kΩ
  • Continuity measurement
  • Power supply: magneto
  • Protection: IP52
  • Electrical safety: IEC 61010 300V CAT III
  • Dimensions: 120 x 120 x 130 mm / 1.06 kg
Datasheet

  • Test voltages: 250, 500 and 1,000 V DC
  • Measurement range: 1 to 5,000 MΩ
  • Power supply: magneto
  • Protection: IP52
  • Electrical safety: IEC 61010 300V CAT III
  • Dimensions : 120 x 120 x 130 mm / 1.06 kg
Datasheet

  • Insulation measurement: up to 1,000 MΩ (1 range) at 500 V DC
  • AC voltage measurement: 0 to 600 V
  • Continuity measurement: -10 Ω to +10 Ω (I = 200 mA)
  • Automatic voltage absence testing by direct measurement
  • Single input on two colour-coded terminals
  • Easy reading of the indication and logarithmic scale
  • Power supply: 4 x LR6 1.5 V batteries
  • Compliant with IEC 61557
  • Electrical safety: IEC 61010 600V Cat III
  • Dimensions: 167 x 106 x 55 mm; weight: 600 g
Datasheet

  • Insulation measurement: up to 1,000 MΩ (1 range) at 500 V and 1,000 V DC
  • AC voltage measurement: 0 to 600 V
  • Continuity measurement: -10 Ω to +10 Ω (I = 200 mA)
  • Resistance measurements: 0 to 1,000 Ω
  • Automatic voltage absence testing  by direct measurement
  • Single input on two colour coded terminals
  • Easy reading of the indication and logarithmic scale
  • Power supply: 4 x LR6 1.5 V batteries
  • Compliant with IEC 61557
  • Electrical safety: IEC 61010 600V Cat III
  • Dimensions: 167 x 106 x 55mm; weight: 600g
Datasheet

Combined device for measuring insulation and continuity of protective and equipotential conductors with 200mA
M70 is a mobile device dedicated to measuring Insulation resistance with test voltage up to 1000VDC and Continuity of protective and equipotential conductors with current of 200mA in private and industrial electric installations.
Thanks to the LOCK function, insulation measurement can be carried out in a continuous manner over time, thus testing the insulation of the target with a duration test. It carries out measurement with a timer, programmable from 2 to 60s.

Datasheet

Combined device for insulation measurement, continuity of protective conductors and multimeter function TRMS

M72 is mainly dedicated to measuring Insulation resistance and Continuity of protective and equipotential conductors with 200mA in electric installations, typically private.

Further to these measurements, M72 has many additional functions such as measurement of phase sequence with 1 terminal, measurement of leakage currents with optional clamp transducer and a powerful multimeter function for measuring voltage and current in true root mean square value (TRMS).

Datasheet

  • Insulation resistance measurement with test voltage up to 5kVDC
  • Measurement range up to 10Tohm
  • FIX mode with test voltage of 100, 250, 500, 1k, 2.5k e 5kVDC
  • ADJUST mode with test voltage selectable from 100 to 5kVDC
  • RAMP mode with selectable duration time and test voltage
  • Selection of 3 type of ramp test
  • Polarization Index (P.I.) measurement
  • Dielectric Absorption Ratio (D.A.R) measurement
  • DC/AC TRMS voltage up to 600V
  • SMOOTH feature for stable measurement results
  • GUARD test lead for surface leakage current compensation
  • MX, MIN limit selectable threshold on measurements
  • Automatic discharging of device under test
  • Fuse protection on power supply
  • LCD display with backlight and bargraph
  • Internal memory for saving results
  • Recall saved results at display
  • RS-232 interface for PC connection
  • Rechargeable internal battery
Datasheet

  • DC test voltage measuring range 500V ÷ 10kV
  • Insulation resistance measuring range 120kΩ ÷ 10TΩ
  • Dielectric strength in DC
  • Test with programmable ramp steps of 25VDC
  • Programmable test timer 1s ÷ 30min
  • Setting of measurement limit value
  • Measurement of polarization index P.I.
  • Measurement of dielectric absorption ratio D.A.R.
  • Measurement of dielectric discharge ratio D.D.
  • Measurement of discharge capacity
  • Automatic discharge of target
  • Measurement of DC/AC voltage up to 600V
  • RS232/optical/USB interface for transferring data onto the PC<7li>
  • EMC 2004/108/CE Directive
  • LVD 2006/95/CE Directive
  • IEC/EN 61010-1
  • IEC/EN61557-1
  • IEC/EN61557-2
  • CE MARK
  • EMC: IEC/EN61326
Datasheet

  • Continuity test with 200mA
  • Insulation with 50, 100, 250, 500, 1000VDC
  • Measure with remote probe (PR400 optional accessory)
  • Contextual help at display
  • Internal memory
  • Optical-USB interface with PC connection
Datasheet

The ΩMegaSafe is a easy testing ohmmeter for rapid testing according to VDE 0413 of protective and earth cables, equipotential bonding and lightning protection cables

Datasheet

Compact, intrinsically safe high-ohm-meter for insulation resistance and leakage resistance test from 1 kΩ up to 20 GΩ with test voltage of 100, 250, 500 or 1000 V. Very compact design and easy operation enable fast, simple tests. For tests on antistatic surfaces and floors, the ISO 1 can be easily extended with test probes and accessories.

Datasheet

Compact, intrinsically safe high-ohm-meter for insulation resistance and leakage resistance test from 1 kΩ up to 2 TΩ with test voltage of 32, 100 oder 500 V. Approved to ATEX for Ex I and Ex II ranges. The ISO 1Ex saves time, with it anti-static floors and surfaces can be tested directly in ex-zones.



Datasheet