Showing all 22 results

  • Input to output galvanic isolation
  • 1- and 2-channel versions
  • No power supply required
  • Fixed ranges
  • Protective Separation acc. to EN 61140
  • Compact DIN-rail mounting
Datasheet
User Manual

  • Transmitter isolation
  • Transmitter powering
  • High accuracy
  • HART communication
  • Fixed ranges
  • Protective Separation acc. to EN 61140
  • Compact DIN-rail mounting
Datasheet
User Manual

  • Input to output galvanic isolation
  • No power supply required
  • Low voltage drop
  • High accuracy
  • High-density DIN-rail mounting
  • Plug-in screw terminals
Datasheet
User Manual

  • Input to output galvanic isolation
  • No power supply required
  • Low voltage drop
  • High accuracy
  • High-density DIN-rail mounting
  • Plug-in screw terminals
Datasheet
User Manual

  • 3-Port-Trennung Schutz vor Messfehlern durch Erdungsprobleme und Störspannungsverschleppung
  • Festeingestellte Signalwandlung Anwendungsbereit ohne zusätzliche Einstellungen
  • Universalnetzteil für 24 VAC/DC Erhöhte Flexibilität in industriellen Anwendungen
  • Sichere Trennung Die Konstruktion und die hohe Prüfspannung (2.5 kV) gewährleisten einen sicheren Schutz des Wartungspersonals und der nachfolgenden Geräte vor unzulässig hoher Spannung
  • Kompakte DIN-Schienenmontage Das 11.2 mm (0.44”) breite und nur 60 mm tiefe Gehäuse zusammen mit einer sehr geringen Eigenerwärmung ermöglicht eine sehr hohe Montagedichte
  • Exzellente Zuverlässigkeit Die verlustarme Stromversorgung gewährleistet eine niedrige Eigenerwärmung und damit eine zuverlässige Langzeitstabilität und hohe Betriebssicherheit
Datasheet
User Manual

  • 3-port isolation
  • Bipolar input signals
  • Fixed ranges
  • Universal power supply for 24 VAC/DC
  • Protective Separation acc. to EN 61140
  • Compact DIN-rail mounting
  • Excellent reliability
Datasheet
User Manual

  • Input to output galvanic isolation
  • No power supply required
  • Low voltage drop
  • Protective Separation acc. to EN 61140
  • High accuracy
  • High-density DIN-rail mounting
  • Plug-in screw terminals
Datasheet
User Manual

  • Input to output galvanic isolation
  • No power supply required
  • Low voltage drop
  • Protective Separation acc. to EN 61140
  • High accuracy
  • High-density DIN-rail mounting
  • Plug-in screw terminals
Datasheet
User Manual

  • Calibrated range selection
  • Universal power supply for 20 to 253 VAC/DC
  • 3-port isolation
  • High-density DIN-rail mounting
  • Plug-in screw terminals
  • Excellent reliability
Datasheet
User Manual

Type of input Active
No. of channels 1 channel
Input signal 0…20 mA 4…20 mA 0…10 V
Output signal 0…20 mA 4…20 mA 0…10 V
Configuration Calibrated range selection
Typical accuracy 0,1 % FS
Isolation level 4 kV, 50 Hz
Working voltage 600 VAC/DC
Power supply 20…253 VAC/DC
Protective separation Yes
Cut-off frequency (-3 dB) 30 Hz/1 kHz switch select.
Ambient temperature 20…+70 °C
Plug-in screw terminals Yes
Housing width 12,5 mm
Installation depth 104 mm
Datasheet
User Manual

  • Fixed ranges
  • Protective Separation acc. to EN 61140
  • High accuracy
  • Universal power supply for 20 to 253 VAC/DC
  • 3-port isolation
  • High-density DIN-rail mounting
  • Plug-in screw terminals
  • Excellent reliability
Datasheet
User Manual

  • Fixed ranges
  • Zero/Span Adjustment
  • Protective Separation acc. to EN 61140
  • High accuracy
  • Universal power supply for 20 to 253 VAC/DC
  • 3-port isolation
  • High-density DIN-rail mounting
  • Plug-in screw terminals
  • Excellent reliability
Datasheet
User Manual

  • Extensive range selection
  • Zero/Span Adjustment
  • Extremely fast response
  • Protective Separation acc. to EN 61140
  • High accuracy
  • Universal power supply for 20 to 253 VAC/DC
  • 3-port isolation
  • High-density DIN-rail mounting
  • Plug-in screw terminals
  • Excellent reliability
Datasheet
User Manual

  • Universal operation of SMART Transmitters Energization and separation of field located 2-, 3- and 4-wire transmitters
  • 3-Port isolation Protection against erroneous measurements due to parasitic voltages or ground loops
  • Extremely slim design 6.2 mm slim housing for a simple and space saving installation
  • Optional In-Rail-Bus mounting rail connector Allows for fast and economical installation
  • Skyddsseparation enligt EN 61140 Konstruktionen och den höga isolationsnivån skyddar servicepersonal och enheter nedströms mot otillåten hög spänning
  • Protective Separation acc. to EN61140 Protects service personnel and downstream devices against impermissibly high voltage
Datasheet
User Manual

  • Galvanic isolation across input and output Protection against erroneous measurements due to parasitic voltages or ground loops
  • No power supply required Saving costs since wiring is reduced and line influences are omitted
  • Extremely slim design Extremely slim casing of 6.2 mm combined with very low self heating allow tight mounting
  • Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage
  • Maximum reliability No maintenance costs
Datasheet
User Manual

  • Galvanic isolation across input and output Protection against erroneous measurements due to parasitic voltages or ground loops
  • No power supply required Saving costs since wiring is reduced and line influences are omitted
  • Extremely slim design Only 3.1 mm DIN-rail per channel
  • Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage
  • Maximum reliability No maintenance costs
Datasheet
User Manual

  • Calibrated signal setting via DIP switch Input and outputs can be set by using DIP switch – high precision without any further adjustment
  • 4-Port isolation Protection against erroneous measurements due to parasitic voltages or ground loops
  • Extremely slim design 6.2 mm slim housing for a simple and space saving DIN rail mounting
  • Optional In-Rail-Bus mounting rail connector Allows for fast and economical installation
  • Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage
  • Maximum reliability No maintenance costs
Datasheet
User Manual

  • Kalibrierte Signalumschaltung per DIP Schalter Ein- und Ausgangsbereich einfach über DIP-Schalter umschaltbar, hochpräzise ohne Nachjustierung
  • 3-Port-Trennung Schutz vor Messfehlern durch Erdungsprobleme und Störspannungsverschleppung
  • Extrem schmale Bauform 6,2  mm schmales Anreihgehäuse für eine einfache und platzsparende Hutschienen-Montage
  • Optional In-Rail-Bus Tragschienenbusverbinder Erlaubt die schnelle und kostengünstige Installation
  • Sichere Trennung nach EN 61140 Schutz des Wartungspersonals und der nachfolgenden Geräte vor unzulässig hoher Spannung
  • Höchste Zuverlässigkeit Kosten für Wartungsaufwand entfallen
Datenblatt
Bedienungsanleitung

  • Calibrated signal setting via DIP switch Input and output range can be set by using DIP switch – high precision without any further adjustment
  • High bandwidth; short response time No signal distortion; no falsification of measured signal
  • Switchable Zero/Span compensation For readjustment of the sensor or field device
  • 3-Port isolation Protection against erroneous measurements due to parasitic voltages or ground loops
  • Extremely slim design 6.2 mm slim housing for a simple and space saving DIN rail mounting
  • Optional In-Rail-Bus mounting rail connector Allows for fast and economical installation
  • Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage
Datasheet
User Manual

  • Extensive range selection
  • Zero/Span Adjustment
  • Extremely fast response
  • Protective Separation acc. to EN 61140
  • High accuracy
  • Universal power supply for 20 to 253 VAC/DC
  • 3-port isolation
  • High-density DIN-rail mounting
  • Plug-in screw terminals
  • Excellent reliability
Datasheet
User Manual

  • For a maximum of 3 A
  • For up to 80 In-Rail-Bus devices
  • Redundant power supply possible, decoupled via diodes
  • Operational and fault signaling via LEDs
  • Output voltage = input voltage - 0.5 V
  • Housing dimensions: 6.2 x 96 x 197 mm
Datenblatt

  • Easy configuration via DIP switch or via INOR-Set
  • Switchable service functions for easy commissioning
  • 3-port isolation Protection against measurement errors due to earthing problems and interference voltage carry-over
  • Extremely slim design 6.2 mm narrow bayed housing for simple and space-saving top-hat rail mounting
  • Optional in-rail bus mounting rail connector allows fast and cost-effective installation
  • Safe isolation according to EN 61140 Protection of maintenance personnel and downstream equipment from impermissibly high voltage
Datasheet
Flyer
User Manual

Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.