Showing all 22 results

  • For the connection of Pt100 and Pt1000 sensors in a 2-, 3- or 4-wire connection
  • For the connection of reed chains in a potentiometer circuit
  • Parameterisation with the WIKAsoft-TT configuration software and electrical connection via quick connector magWIK
  • Connection terminals also accessible from the outside
  • Accuracy < 0.2 K (< 0,36 °F) / 0.1 %
Datasheet
User Manual

  • TÜV zertifizierte SIL-Version für Schutzeinrichtungen entwickelt nach IEC 61508 (Option)
  • Einsatz in Sicherheitsanwendungen bis SIL 2 (einzelnes Gerät) und SIL 3 (redundante Verschaltung)
  • Konfigurierbar mit nahezu jedem offenen Soft- und Hardwaretool
  • Universell für den Anschluss von 1 oder 2 Sensoren - Widerstandsthermometer, Widerstandssensor - Thermoelement, mV-Sensor - Potentiometer
  • Signalisierung gemäß NAMUR NE43, Sensorbruchüberwachung gemäß NE89, EMV gemäß NE21
Datenblatt
Bedienungsanleitung

  • TÜV certified SIL version for protection systems developed per IEC 61508 (option)
  • Operation in safety applications to SIL 2 (single instrument) and SIL 3 (redundant configuration)
  • Configurable with almost all soft- and hardware tools
  • Universal for the connection of 1 or 2 sensors
    • Resistance thermometer, resistance sensor (up to 2 x 3-wire)
    • Thermocouple, mV sensor
    • Potentiometer
  • Signalling in accordance with NAMUR NE43, sensor monitoring in accordance with NE89, EMC in accordance with NE21, self-monitoring and diagnostics of field instruments in accordance with NE107
Datenblatt
Datenblatt

  • Model OTMT84: PROFIBUS® PA profile 3.02
  • Model OTMT85: FOUNDATION™ Fieldbus H1
  • Explosion-protected version Ex ia (intrinsically safe/FISCO) and Ex ec available
Datasheet
User Manual
User Manual

Digital 2-wire transmitter for Pt100 and Pt1000 with wireless communication

  • Type: Digital
  • Input: RTD
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

Digital 2-wire transmitter for thermocouple with wireless communication

  • Type: Digital
  • Input: TC
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

Analog Adjustable 3-wire Transmitters
  • Type: Analog
  • Input: RTD
  • Utgång: 0-10 V
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

Analog Adjustable 3-wire Transmitters
  • Type: Analog
  • Input: RTD
  • Utgång: 0-10 V
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

Analog Adjustable 2-wire Transmitters
  • Type: Analog
  • Input: RTD, thermocouple
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel


Datasheet

Analog Adjustable 2-wire Transmitters
  • Type: Analog
  • Input: RTD, thermocouple
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel


Datasheet

Type Head-mounted
Input RTD
Input RTD Pt100
Type Of Transmitter Analog
Output 4-20 mA
Isolation Unisolated
Measuring channels 1 channel
Input connections 3-wire connection
Power supply 8.5 to 32 VDC
Typical accuracy Max. of ±0.1 °C / ±0.2 °F or ±0,1 % of span
Quick delivery Yes
Datasheet

Type Head mounted
Input RTD
Input RTD Pt100
Type of transmitter Digital
Output 4-20 mA
Isolation Unisolated
Measuring channels 1 channel
Sensor connection 3-wire connection
Power Supply Standard version: 6 to 32 VDC Ex version: 8 to 30 VDC
Typical accuracy Max. ±0.1K or ±0,1 % of span
Approvals (IPAQ-C202X) ATEX: II 1G Ex ia IIC T6…T4 Ga IECEx: Ex ia IIC T6…T4 Ga
Datasheet

Type Head mounted
Input RTD
Input RTD Pt100
Type of transmitter Digital
Output 4-20 mA
Isolation Unisolated
Measuring channels 1 channel
Sensor connection 3-wire connection
Power Supply Standard version: 6 to 32 VDC Ex version: 8 to 30 VDC
Typical accuracy Max. ±0.1K or ±0,1 % of span
Approvals (IPAQ-C202X) ATEX: II 1G Ex ia IIC T6…T4 Ga IECEx: Ex ia IIC T6…T4 Ga
Datasheet

Universal 2-wire transmitter with wireless communication
  • Type: Digital
  • Input: RTD, thermocouple, Universal
  • Output: 4-20 mA
  • Isolation: Isolated
  • Measuring channels: 1 channel
Datasheet

Universal 2-wire transmitter with wireless communication
  • Type: Digital
  • Input: RTD, thermocouple, Universal
  • Output: 4-20 mA
  • Isolation: Isolated
  • Measuring channels: 1 channel


Datasheet

High-precision Universal Programmable 2-wire Transmitter
  • Type: Digital
  • Input: RTD, thermocouple, Universal
  • Output: 4-20 mA
  • Isolation: Isolated
  • Measuring channels: 1 channel
Datasheet

High-precision Universal Programmable 2-wire Transmitter
  • Type: Digital
  • Input: RTD, thermocouple, Universal
  • Output: 4-20 mA
  • Isolation: Isolated
  • Measuring channels: 1 channel
Datasheet

 
Typ Kopftransmitter
Eingang RTD; Thermoelement; Universal
Eingang Widerstandsthermometer Pt100, Pt1000, Ni100, Ni1000
Eingang Thermoelemente Typ B, C, E, J, K, L, N, R, S, T, U
Transmittertyp Digital
Ausgang 4-20 mA; HART®
Galvanische Trennung Ja
Messkanäle 1 Kanal
Eingang 3-, 4-Leiteranschluss
Versorgungsspannung MESO-H: 10 bis 42 VDC; MESO-HX: 12 bis 30 VDC
Zulassung ATEX; CSA; FM; HART®
Typische Genauigkeit 0.1% der Messspanne
INOR Schnelllieferprogramm Ja
Datasheet

Basic Programmable 2-wire Transmitter

  • Type: Digital
  • Input: RTD thermocouple
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

Basic Programmable 2-wire Transmitter

  • Type: Digital
  • Input: RTD thermocouple
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

2-wire head transmitter with and without HART communications interface for mounting in the connection head of the temperature sensor.

Datasheet
User Manual

2-wire head transmitter with and without HART communications interface for mounting in the connection head of the temperature sensor.

Datasheet
User Manual

Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.