ISA - ground grid testing
STS 3000 & TD 5000 and RTCD - Primary test and power transformer diagnostic system
- Fully automatic
- Primary injection testing capabilities: up to 800 A or up to 5000 A / 7000 A, with the optional module BUX 5000
- Variable output frequency: 15 - 500 Hz
- Power dissipation factor test with the optional module TD 5000 ( voltage up to 12 kV)
- 2000 V AC high-pot test
- Local control by large color display
- PADS - Power Apparatus Diagnostic Software for automatic testing, assessment and report
- IEC 61850-9-2 communication protocol
- Patented technology for Capacitance and Tan Delta measurement
- USB interface and Ethernet interface for PC connection.< Compact and lightweight.
STS 5000/STS 4000 & STLG with earth kit - Diagnostic test system for current, voltage, power transformers and ground grid
- Fully automatic
- Primary injection testing capabilities: up to 800 A or up to 5000 A / 7000 A, with the optional module BUX 5000
- STLG - line and grid module for ground grid resistance test
- Variable output frequency: 15 - 500 Hz
- Power dissipation factor test with the optional module TD 5000 ( voltage up to 12 kV)
- 2000 V AC high-pot test
- Local control by large color display
- PADS - Power Apparatus Diagnostic Software for automatic testing, assessment and report
- IEC 61850-9-2 communication protocol
- Patented technology for Capacitance and Tan Delta measurement
- USB interface and Ethernet interface for PC connection.
- Compact and lightweight.
STS 5000/STS 4000 & STLG – STSG with earth kit - Diagnostic test system for current, voltage, power transformers and ground grid
- Fully automatic
- Primary injection testing capabilities: up to 800 A or up to 5000 A / 7000 A, with the optional module BUX 5000
- STLG - line and grid module for ground grid resistance test
- STSG - safety grounding module protecting the operator against possible high voltage spikes
- Variable output frequency: 15 - 500 Hz
- Power dissipation factor test with the optional module TD 5000 ( voltage up to 12 kV)
- 2000 V AC high-pot test
- Local control by large color display
- PADS - Power Apparatus Diagnostic Software for automatic testing, assessment and report
- IEC 61850-9-2 communication protocol
- Patented technology for Capacitance and Tan Delta measurement
- USB interface and Ethernet interface for PC connection.
- Compact and lightweight.
eKAM - Electronic and automatic primary injection test system up to 2000 A, 3000 A and 5000 A
- Fully automatic
- Two portable units: control and current units
- High current output: up to 2000 A, 3000 A and 5000 A
- Variable output frequency: 15 - 500 Hz
- CT ratio, burden and polarity test
- Large graphic display
- Advanced Test & Data Management Software for test set control, results storage and analysis
- Step & touch plus ground resistance tests with STLG option
- Reduced timing test
- USB interface and Ethernet interface for PC connection
- IEC 61850-9-2 sample values protocol interface
- Compact and lightweight