• Automatic alarming above threshold voltage as default
  • Fast response time, less than 1 second
  • High impact ABS body
  • Proven in the field world-wide
  • Self-test facility
  • Easy to use and lightweight (0.6kg)
  • Suitable for indoor/outdoor use
  • -25°C to +55°C operating temperature range
  • Shock & drop resistant
  • Standard safety yellow (other colors available)
  • Various rod adaptors available to suit different operating rod styles
  • Easy access for battery replacement
Datasheet

  • Designed for use on capacitive test points of separable connectors
  • Automatic alarming above threshold voltage as default
  • Able to test insulated polymetric cables in fused cable boxes
  • Up to 66kV Range and 100V or 600V Threshold
  • High Impact ABS body
  • Self test facility
  • Easy to use and Lightweight (0.6kg)
  • Suitable for indoor/Outdoor use
  • -25°C to +55°C operating temperature range
  • Shock & drop resistant
  • Easy access for battery replacement
Datasheet

  • Small and compact for use in confined spaces
  • High immunity to interference fields
  • Utilizes proven resistor chain method of measurement
  • Proven in the field world-wide
  • Self test facility
  • Can be used on DC systems
  • Suitable for indoor/outdoor use
  • -25°C to +55°C operating temperature range
  • Clear safety limit marks
  • Operator hand guard with viewing window
  • Automatic battery check on Proving Unit
  • Easy access for battery replacement
Datasheet

  • Can be used on DC high voltage overhead lines up to 3000V DC
  • Earth lead and clamp attached to long-length handle
  • Red LED indicators when voltage is detected
  • Loud 70dB alarm when voltage is detected
  • Audible indication: Buzzer, 3.1 kHz tone, modulated @ 2Hz
  • Can be used on third rail installations
  • Battery check function
  • Standard Thresholds: 250V / 500V / 1000V DC
  • Resistor Chain: 1.5MΩ / 3MΩ / 6MΩ
  • Operating time: 5 minutes nominal
Datasheet

  • All in one kit
  • Up to 33kV voltage testing
  • Overhead lines phasing
  • Proven in the field world-wide
  • High reliability
  • Lightweight and easy to transport
  • Robust heavy duty case
  • -25°C to +55°C operating temperature range
  • Self test facility
  • Shock & drop resistant
Datasheet

  • Automatic alarming above threshold voltage as default
  • 11kV / 33kV Voltage Range for WPC1000
  • 66kV / 132kV Voltage Range for WPC2000
  • Positive indication of phase relationship
  • 50m operating range in free air
  • Built-in self-check facility
  • 433.9mHz operating frequency
  • Shock and drop resistant
  • High impact ABS body
  • -25°C to +55°C operating temperature range
  • Indoor/Outdoor use regardless of weather conditions
  • Easy access for battery replacement
  • Built-in self-check facility
  • Self proving facility
  • Various rod adaptors available
Datasheet

  • Verify voltage presence in high voltage systems
  • Can identify voltages as low as 200V
  • Can identify voltages as high as 15kV AC/DC
  • Suitable for checking busbars and switchgear enclosures
  • Ideal for use in cramped spaces
  • High immunity to interference fields
  • Proven resistor chain method of measurement
  • Safety limits are clearly marked
  • Features a handguard with a viewing window
  • Supplied with a proving unit with automatic battery check
  • Suitable for use inside and outside (provided it is used in dry conditions)
  • Can be used to check DC systems
  • Operating temperature: – 5˚C to + 50˚C
Datasheet
User Manual

  • Designed for “Dead” checks on Switchgear
  • Suitable for HVD Types rated up to 33kV
  • Includes a Capacitive Bent End Adapter for limited current
  • Compliant with IEC standard 61481
Datasheet

  • Determines whether HV systems are live or dead
  • Up to 25kV Range and 7.5kV Threshold
  • Automatic alarming above threshold voltage as default
  • Easy to use and Lightweight (0.6kg)
  • Fast response time , less than 1 second
  • High Impact ABS body
  • Self test facility
  • Indoor/Outdoor use
  • -25°C to +55°C operating temp range
  • Shock & drop resistant
Datasheet
User Manual

  • Determines whether HV systems are live or dead
  • 11/33kV Range and 2.5kV Threshold
  • Automatic alarming above threshold voltage as default
  • Easy to use and Lightweight (0.6kg)
  • Fast response time , less than 1 second
  • High Impact ABS body
  • Self test facility
  • Indoor/Outdoor use
  • -25°C to +55°C operating temp range
  • Shock & drop resistant
Datasheet
User Manual

  • Determines whether HV systems are live or dead
  • 11/33kV Range and 1.2kV Threshold
  • Automatic alarming above threshold voltage as default
  • Easy to use and Lightweight (0.6kg)
  • Fast response time , less than 1 second
  • High Impact ABS body
  • Self test facility
  • Indoor/Outdoor use
  • -25°C to +55°C operating temp range
  • Shock & drop resistant
Datasheet
User Manual

  • Determines whether HV systems are live or dead
  • Up to 132kV Range and 15kV Threshold
  • Automatic alarming above threshold voltage as default
  • Easy to use and Lightweight (0.6kg)
  • Fast response time , less than 1 second
  • High Impact ABS body
  • Self test facility
  • Indoor/Outdoor use
  • -25°C to +55°C operating temp range
  • Shock & drop resistant
Datasheet
User Manual

  • Determines whether HV systems are live or dead
  • 6.6/33kV Range and 1.2kV Threshold
  • Automatic alarming above threshold voltage as default
  • Easy to use and Lightweight (0.6kg)
  • Fast response time , less than 1 second
  • High Impact ABS body
  • Self test facility
  • Indoor/Outdoor use
  • -25°C to +55°C operating temp range
  • Shock & drop resistant
Datasheet
User Manual

  • Determines whether HV systems are live or dead
  • 11/66kV Range and 2.5kV Threshold
  • Automatic alarming above threshold voltage as default
  • Easy to use and Lightweight (0.6kg)
  • Fast response time , less than 1 second
  • High Impact ABS body
  • Self test facility
  • Indoor/Outdoor use
  • -25°C to +55°C operating temp range
  • Shock & drop resistant
Datasheet
User Manual

  • Determines whether HV systems are live or dead
  • 33/132kV Range and 6kV Threshold
  • Automatic alarming above threshold voltage as default
  • Easy to use and Lightweight (0.6kg)
  • Fast response time , less than 1 second
  • High Impact ABS body
  • Self test facility
  • Indoor/Outdoor use
  • -25°C to +55°C operating temp range
  • Shock & drop resistant
Datasheet
User Manual

  • Determines whether HV systems are live or dead
  • 33/66kV Range and 4kV Threshold
  • Automatic alarming above threshold voltage as default
  • Easy to use and Lightweight (0.6kg)
  • Fast response time , less than 1 second
  • High Impact ABS body
  • Self test facility
  • Indoor/Outdoor use
  • -25°C to +55°C operating temp range
  • Shock & drop resistant
User Manual

  • Determines whether HV systems are live or dead
  • 66/132kV Range and 9kV Threshold
  • Automatic alarming above threshold voltage as default
  • Easy to use and Lightweight (0.6kg)
  • Fast response time , less than 1 second
  • High Impact ABS body
  • Self test facility
  • Indoor/Outdoor use
  • -25°C to +55°C operating temp range
  • Shock & drop resistant
User Manual

  • Determines whether HV systems are live or dead
  • Designed for use on capacitive test points of separable connectors
  • Able to test insulated polymetric cables in fused cable boxes
  • 2/11kV Range and 100V Threshold
  • Automatic alarming above threshold voltage as default
  • Easy to use and Lightweight (0.6kg)
  • Fast response time , less than 1 second
  • High Impact ABS body
  • Self test facility
  • Indoor/Outdoor use
  • -25°C to +55°C operating temp range
  • Shock & drop resistant
Datasheet
User Manual

  • Determines whether HV systems are live or dead
  • Designed for use on capacitive test points of separable connectors
  • Up to 33kV Range and 600V Threshold
  • Automatic alarming above threshold voltage as default
  • Easy to use and Lightweight (0.6kg)
  • Fast response time , less than 1 second
  • High Impact ABS body
  • Self test facility
  • Indoor/Outdoor use
  • -25°C to +55°C operating temp range
  • Shock & drop resistant
Datasheet
User Manual

  • Can be used on DC high voltage overhead lines up to 1500V DC
  • Earth lead and clamp attached to long-length handle
  • Red LED indicators when voltage is detected
  • Loud 70dB alarm when voltage is detected
  • Audible indication: Buzzer, 3.1 kHz tone, modulated @ 2Hz
  • Can be used on third rail installations
  • Battery check function
  • Standard Threshold: 500V DC
  • Resistor Chain: 3MΩ
  • Operating time: 5 minutes nominal
Datasheet
User Manual

  • Can be used on DC high voltage overhead lines up to 3000V DC
  • Earth lead and clamp attached to long-length handle
  • Red LED indicators when voltage is detected
  • Loud 70dB alarm when voltage is detected
  • Audible indication: Buzzer, 3.1 kHz tone, modulated @ 2Hz
  • Can be used on third rail installations
  • Battery check function
  • Standard Threshold: 1000V DC
  • Resistor Chain: 6MΩ
  • Operating time: 5 minutes nominal
Datasheet
User Manual

  • Can be used on DC high voltage overhead lines up to 750V DC
  • Earth lead and clamp attached to long-length handle
  • Red LED indicators when voltage is detected
  • Loud 70dB alarm when voltage is detected
  • Audible indication: Buzzer, 3.1 kHz tone, modulated @ 2Hz
  • Can be used on third rail installations
  • Battery check function
  • Standard Threshold: 250V DC
  • Resistor Chain: 1.5MΩ
  • Operating time: 5 minutes nominal
Datasheet
User Manual

  • Detects HV voltages and compares phases
  • Self powered operation
  • Indicates the presence of live voltage on circuits up to 3.3kV
  • Positive phasing test
  • High voltage measurement
  • Suitable for both dry and wet conditions
  • High quality fibreglass rod
  • Proving and repeater units
  • DC version available
  • High immunity to interference field
Datasheet
User Manual

  • Accessory kit for WPC1000
  • Enables phase comparison in switchgear cubicles
  • Eliminates trailing wires
  • Enhanced phasing distance
  • Convenient carry bag
  • Includes two capacitive coupled 60° bent end adaptors
  • Two operating handles for easy use
Datasheet

  • Fast response time
  • High impact ABS body
  • Indoor/Outdoor use regardless of weather conditions
  • Automatic alarming above threshold voltage as default
  • 11kV / 33kV Voltage Range
  • Range – 50m in air
  • ‐25°C to +55°C operating temp range
  • Shock and drop resistant
  • Various rod adaptors available
  • Easy access for battery replacement
  • Self Proving facility
  • Built in self-check facility
  • Operating Frequency – 433.9mHz
Datasheet

  • Fast response time
  • High impact ABS body
  • Indoor/Outdoor use regardless of weather conditions
  • Automatic alarming above threshold voltage as default
  • 66kV / 132kV Voltage Range
  • Range – 50m in air
  • ‐25°C to +55°C operating temp range
  • Shock and drop resistant
  • Various rod adaptors available
  • Easy access for battery replacement
  • Self Proving facility
  • Built in self-check facility
  • Operating Frequency – 433.9mHz
Datasheet

  • Detects HV voltages and compares phases
  • Self powered operation
  • Indicates the presence of live voltage on circuits up to 6.6kV
  • Positive phasing test
  • High voltage measurement
  • Suitable for both dry and wet conditions
  • High quality fibreglass rod
  • Proving and repeater units
  • DC version available
  • High immunity to interference field
Datasheet
User Manual

  • Detects HV voltages and compares phases
  • Self powered operation
  • Indicates the presence of live voltage on circuits up to 11kV
  • Positive phasing test
  • High voltage measurement
  • Suitable for both dry and wet conditions
  • High quality fibreglass rod
  • Proving and repeater units
  • DC version available
  • High immunity to interference field
Datasheet
User Manual

  • Detects HV voltages and compares phases
  • Self powered operation
  • Indicates the presence of live voltage on circuits up to 13.8kV
  • Positive phasing test
  • High voltage measurement
  • Suitable for both dry and wet conditions
  • High quality fibreglass rod
  • Proving and repeater units
  • DC version available
  • High immunity to interference field
Datasheet
User Manual

  • Detects HV voltages and compares phases
  • Self powered operation
  • Indicates the presence of live voltage on circuits up to 33kV
  • Positive phasing test
  • High voltage measurement
  • Suitable for both dry and wet conditions
  • High quality fibreglass rod
  • Proving and repeater units
  • DC version available
  • High immunity to interference field
Datasheet
User Manual

  • Detects HV leakages
  • Self powered operation
  • Indicates the presence of live voltage on circuits up to 33kV
  • High voltage measurement
  • Suitable for both dry and wet conditions
  • High quality fibreglass rod
  • Proving and repeater units
  • High immunity to interference field


High-Voltage Testing (AC Systems)

AC high-voltage tests assess insulation strength and dielectric integrity of electrical equipment. By applying elevated AC voltage, insulation under stress is tested to detect weaknesses, creeping paths or ageing before operation — ensuring safety and reliability.

FAQ

What does a high-voltage tester check?

It tests dielectric strength of insulation, clearance and creepage distances, leakage current behavior and dielectric stability under stress.

When is a high-voltage test required?

Before commissioning new equipment, after installation or repair, after transport, when switching voltage levels, and periodically for maintenance or safety checks.

What test voltage is used?

Significantly higher than the nominal operating voltage, depending on insulation class and component specifications. The exact value depends on application and safety requirements.

How long shall the test last?

From several seconds up to a few minutes — enough time to reveal insulation weakness or breakdown under stress.

What is observed during the test?

Leakage currents, insulation stability, presence of arcs or breakdowns, voltage stability, temperature changes and after test the integrity of insulation.

What defects can be detected?

Breakdown of insulation, insufficient clearance, moisture inside insulation, manufacturing or assembly defects, ageing or damage due to environmental factors.

Can mechanical faults be detected by AC testing?

No — mechanical issues such as poor soldering, loose contacts or corrosion are not visible. The test only assesses insulation integrity.

How should the test environment be prepared?

Dry, clean environment, no conductive foreign objects nearby, all exposed conductors isolated or earthed, sufficient clearance to personnel and other equipment.

Which safety measures are mandatory?

Restricted test area, earth grounding, protection against unintended re-energisation, discharge circuits after test, personal protective equipment, warning notices and secure access control.

Who is authorized to perform high-voltage tests?

Qualified personnel with training in high-voltage testing, equipment handling and safety protocols; tests must be properly planned, executed and documented.

How should results be documented?

Include test object, test voltage, duration, observed leakage currents or breakdowns, environmental conditions, result (pass/fail), date, technician and test equipment used.

When should tests be repeated?

After modifications, repairs, transport, exposure to overload or stress or at scheduled inspection intervals.

Are partial or simplified tests possible?

Yes. An insulation resistance test or reduced-voltage stress test may be conducted where full high-voltage testing is not required or safe.

What risks exist with high-voltage tests?

Electrocution, arc flashes, insulation degradation, damaging sensitive components, exposure to stored energy or residual charge — safe procedures are essential.

How to verify insulation after the test?

After discharge and return to normal operating conditions, insulation resistance or continuity checks should be made; possibly additional functional tests to confirm integrity.

Are there cases where AC-testing is unsuitable?

Yes — for electronic modules, control circuits, sensitive insulation materials or components with semiconductors, where high stress may cause damage.

Is testing in moist environment allowed?

Generally not — moisture increases leakage current and risk of unpredictable behavior. Only in dry, controlled conditions should testing be performed.

How are complex assemblies or devices tested?

Modules with electronic parts should be isolated or removed; only insulation-relevant parts are tested. Sensitive electronics must be protected.

What documentation and safety record is required?

A detailed test report, indication of object tested, discharge confirmation, earth-grounding verification, release note for return to service, and proper archiving.

Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.