Showing all 12 results

  • Compact and robust design per ISO 5167-2
  • Installation between existing flanges (ASME/EN)
  • Complete measuring point consisting of orifice plate, valve manifold and differential pressure transmitter available
  • Simple installation without differential pressure lines
  • Accuracy ≤ ±0.5 % of the actual flow rate and a repeatability of the measurement of 0.1 %
Datasheet
User Manual

  • Suitable for liquids, gases and steam
  • Wide turndown
  • Low requirements for straight upstream and downstream pipes
  • Low costs and low maintenance effort
Datasheet
User Manual

  • Highest accuracy and energy efficiency
  • No upstream and downstream pipes required
  • Wide range of applications
Datasheet
User Manual

  • No need for straight upstream and downstream pipes
  • Highest accuracy
  • Energy-efficient
  • Flexible installation
  • Wide variety of applications
Datasheet
User Manual

  • For requirements in short straight up- and downstreampipes
  • Suitable for liquid, gas and steam flow measurement
  • Compact version available
  • Accuracy 1 % ... 2 % depending on beta ratio andReynolds number
  • Repeatability 0.1 % of flow rate
Datasheet

  • Max. operating temperature and pressure limited by material and rating
  • Suitable for liquid, gas and steam flow measurement
  • Accuracy ≤ ±1.0 % of actual flow rate
  • Repeatability of measurement 0.1 %
Datasheet
User Manual

  • Low maintenance through robust design
  • For highly viscous and particle-laden media
  • Low permanent pressure loss
  • For very high and very low Reynolds numbers
  • Bi-directional flow measurement
  • Per ISO 5167 part 6 (2019)
Datasheet
User Manual

  • Suitable for liquid, gas and steam flow measurement
  • Accuracy ≤ ±2 % of actual flow rate
  • Repeatability of measurement 0.1 %
  • Ensure the lowest pressure loss in the family of primary flow elements (approx. < 1 %)
Datasheet
User Manual

  • Suitable for liquid, gas and steam flow measurement
  • Optimum solution for measuring the flow of steam
  • Accuracy ≤ ±0.1 % of actual flow rate
  • Repeatability of measurement 0.1 %
  • Lowest pressure loss in the family of primary flow elements
Datasheet
User Manual

  • Max. operating temperature and pressure limited by material and flange
  • Suitable for liquid, gas and steam flow measurement
  • Accuracy ≤ ±0.5 % of actual flow rate
  • Repeatability of measurement of 0.1 %
Datasheet

  • Suitable for liquid, gas, and steam applications
  • Single and multi bore solutions
  • Multi-step executions
Datasheet

  • Suitable for liquid, gas and steam flow measurement
  • Accuracy ≤ ±0.5 % of actual flow rate
  • Repeatability of measurement 0.1 %
  • Lowest pressure loss in the family of primary flow elements
  • Calibration may be performed if required
Datasheet
User Manual