- Compact and robust design per ISO 5167-2
- Installation between existing flanges (ASME/EN)
- Complete measuring point consisting of orifice plate, valve manifold and differential pressure transmitter available
- Simple installation without differential pressure lines
- Accuracy ≤ ±0.5 % of the actual flow rate and a repeatability of the measurement of 0.1 %
Datasheet |
User Manual |
- Suitable for liquids, gases and steam
- Wide turndown
- Low requirements for straight upstream and downstream pipes
- Low costs and low maintenance effort
Datasheet |
User Manual |
- Highest accuracy and energy efficiency
- No upstream and downstream pipes required
- Wide range of applications
Datasheet |
User Manual |
- No need for straight upstream and downstream pipes
- Highest accuracy
- Energy-efficient
- Flexible installation
- Wide variety of applications
Datasheet |
User Manual |
- For requirements in short straight up- and downstreampipes
- Suitable for liquid, gas and steam flow measurement
- Compact version available
- Accuracy 1 % ... 2 % depending on beta ratio andReynolds number
- Repeatability 0.1 % of flow rate
Datasheet |
- Max. operating temperature and pressure limited by material and rating
- Suitable for liquid, gas and steam flow measurement
- Accuracy ≤ ±1.0 % of actual flow rate
- Repeatability of measurement 0.1 %
Datasheet |
User Manual |
- Low maintenance through robust design
- For highly viscous and particle-laden media
- Low permanent pressure loss
- For very high and very low Reynolds numbers
- Bi-directional flow measurement
- Per ISO 5167 part 6 (2019)
Datasheet |
User Manual |
- Suitable for liquid, gas and steam flow measurement
- Accuracy ≤ ±2 % of actual flow rate
- Repeatability of measurement 0.1 %
- Ensure the lowest pressure loss in the family of primary flow elements (approx. < 1 %)
Datasheet |
User Manual |
- Suitable for liquid, gas and steam flow measurement
- Optimum solution for measuring the flow of steam
- Accuracy ≤ ±0.1 % of actual flow rate
- Repeatability of measurement 0.1 %
- Lowest pressure loss in the family of primary flow elements
Datasheet |
User Manual |
- Max. operating temperature and pressure limited by material and flange
- Suitable for liquid, gas and steam flow measurement
- Accuracy ≤ ±0.5 % of actual flow rate
- Repeatability of measurement of 0.1 %
Datasheet |
- Suitable for liquid, gas, and steam applications
- Single and multi bore solutions
- Multi-step executions
Datasheet |
- Suitable for liquid, gas and steam flow measurement
- Accuracy ≤ ±0.5 % of actual flow rate
- Repeatability of measurement 0.1 %
- Lowest pressure loss in the family of primary flow elements
- Calibration may be performed if required
Datasheet |
User Manual |

Datasheet