The KTY Temperature Transmitter DT 45600 is used for measure industrial process signals. It converts KTY sensor signals to isolated standard signals.
  • Measuring input for all KTY temperature sensors calibrated standard measuring ranges, ready to use
  • Easy configurable via DIP switches or via USB interface without auxiliary power supply
  • Switchable Service Functions for an easy commissioning
  • 3-port isolation Protection against erroneous measurements due to parasitic voltages or ground loops
  • Extremely slim design 6.2 mm slim housing for a simple and space saving DIN rail mounting
  • Optional In-Rail-Bus mounting rail connector allows for fast and economical installation
  • Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage
  • 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
Datasheet
Ex and UL instructions
User Manual

The Ni Temperature Transmitter DT 45400 is used for measure industrial process signals. It converts Ni sensor signals to isolated standard signals.
  • Measuring input for all Ni temperature sensors calibrated standard measuring ranges ready to use
  • Easy configurable via DIP switches or via USB interface without auxiliary power supply
  • Switchable Service Functions for an easy commissioning
  • 3-port isolation Protection against erroneous measurements due to parasitic voltages or ground loops
  • Extremely slim design 6.2 mm slim housing for a simple and space saving DIN rail mounting
  • Optional In-Rail-Bus mounting rail connector allows for fast and economical installation
  • Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage
  • 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
Datasheet
Ex and UL instructions
User Manual

The Pt Temperature Transmitter DT 45200 is used for measure industrial process signals. It converts Pt sensor signals to isolated standard signals.
  • Measuring input for all Pt temperature sensors more than 1200 standard ranges ready to use
  • Easy configurable via DIP switches or via USB interface without auxiliary power supply
  • Switchable Service Functions for an easy commissioning
  • 3-port isolation Protection against erroneous measurements due to parasitic voltages or ground loops
  • Extremely slim design 6.2 mm slim housing for a simple and space saving DIN rail mounting
  • Optional In-Rail-Bus mounting rail connector allows for fast and economical installation
  • Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage
  • 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
Datasheet
Ex and UL instructions
User Manual

The Resistance Transmitter DR 41 converts the sensor resistance value to a standard signal and makes it galvanic isolated available on output.
  • Cost optimized resistance measuring in 2-, 3- and 4-wire sensor connection
  • Only 60 mm installation depth, 11.2 mm wide Can be installed in economical standard terminal boxes
  • Fixed ranges, easy to use Ready to use without any settings or adjustments
  • Zero/Span compensation on front panel for readjustment of sensor and measuring equipment or line compensation at 2-wire sensor connection
  • True 3-port separation Protection against erroneous measurements due to parasitic voltages or ground loops
  • Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage
  • Unlimited use with 24 V AC/DC power supply Universally applicable for all measurement and industrial applications
  • 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
Datasheet
User Manual

The Temperature Transmitter DR 44 converts the sensor signal on input to temperature linear standard signal and makes it galvanic isolated available on output.
  • Cost optimized design Economical temperature measuring for standard applications with Pt100 sensor with 4-wire connection
  • Only 60 mm installation depth, 11.2 mm wide Can be installed in economical standard terminal boxes
  • Fixed ranges, easy to use Ready to use without any settings or adjustments
  • Zero/Span compensation on front panel for readjustment of sensor signal or measuring equipment
  • True 3-port separation Protection against erroneous measurements due to parasitic voltages or ground loops
  • Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage
  • Unlimited use with 24 V AC/DC power supply Universally applicable for all measurement and industrial applications
  • 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
Datasheet
User Manual

The Temperature Transmitter DR 4700 converts the sensor signal on input to temperature linear standard signal 0/4 to 20 mA or 0 to 5/10 V.
  • Extensive range selection Measurement range within -100 to +600 °C for Pt100 and Pt1000 sensors
  • Easy selection of configuration Measurement range, type of sensor, sensor connection and output signal can be easily set by using DIP switch
  • Universal power supply for 20 to 253 V AC/DC Applicable world-wide for all common supply voltages
  • 3-port isolation Protection against erroneous measurements due to parasitic voltages or ground loops
  • Ultra small sized housing 12.5 mm housing with plug-in screw terminal blocks
  • Protective Separation Protects service personnel and downstream devices against impermissibly high voltage
  • Maximum reliability No maintenance costs
  • 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
Datasheet
User Manual
User Manual

The Temperature Transmitter DR 48 converts the sensor signal on input to temperature linear standard signal and makes it galvanic isolated available on output.
  • Cost optimized design Economical temperature measuring for standard applications with Pt100 sensor with 2-wire or 3-wire connection
  • Only 60 mm installation depth, 11.2 mm wide Can be installed in economical standard terminal boxes
  • Fixed ranges, easy to use Ready to use without any settings or adjustments
  • Zero/Span compensation on front panel for readjustment of sensor signal or measuring equipment
  • True 3-port separation Protection against erroneous measurements due to parasitic voltages or ground loops
  • High reliability and long-term stability New APT technology for signal processing
  • Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage
  • Cross-connector for the auxiliary power supply Fast and economical installation
  • Unlimited use with 24 V AC/DC power supply Universally applicable for all measurement and industrial applications
  • 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
Datasheet
User Manual

The Temperature Transmitters DR 49 converts the sensor signal on input to temperature linear standard signal and makes it galvanic isolated available on output.
  • Cost optimized design Economical temperature measuring for standard applications with Pt1000 sensor with 2-wire or 3-wire connection
  • Only 60 mm installation depth, 11.2 mm wide Can be installed in economical standard terminal boxes
  • Fixed ranges, easy to use Ready to use without any settings or adjustments
  • Zero/Span compensation on front panel for readjustment of sensor signal or measuring equipment
  • True 3-port separation Protection against erroneous measurements due to parasitic voltages or ground loops
  • Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage
  • Unlimited use with 24 V AC/DC power supply Universally applicable for all measurement and industrial applications
  • 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
Datasheet
User Manual

The programmable Temperature Transmitter DT 45000 is used for measure industrial process signals. It converts Pt, Ni, KTY or TC sensor signals as well as poti, resistor or mV signals on input to isolated standard signals.
  • Universal Measuring Input for all common industrial sensor signals
  • Easy configurable via USB or DIP switches complete programmable via USB interface or selectable per DIP switch
  • Switchable Service Functions Simulation and Teach-In Function for an easy commissioning
  • 3-port isolation Protection against erroneous measurements due to parasitic voltages or ground loops
  • Extremely slim design 6.2 mm slim housing for a simple and space saving DIN rail mounting
  • Optional In-Rail-Bus mounting rail connector allows for fast and economical installation
  • Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage
  • 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
Datasheet
Ex and UL instructions
User Manual

The TC Temperature Transmitter DT 45800 is used for measure industrial process signals. It converts Thermocouple sensor signals to isolated standard signals.
  • Measuring input for all TC temperature sensors more than 1800 standard ranges ready to use
  • Easy configurable via DIP switches or via USB interface without auxiliary power supply
  • Switchable Service Functions for an easy commissioning
  • 3-port isolation Protection against erroneous measurements due to parasitic voltages or ground loops
  • Extremely slim design 6.2 mm slim housing for a simple and space saving DIN rail mounting
  • Optional In-Rail-Bus mounting rail connector allows for fast and economical installation
  • Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage
  • 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
Datasheet
Ex and UL instructions
User Manual

  • For the connection of Pt100 and Pt1000 sensors in a 2-, 3- or 4-wire connection
  • For the connection of reed chains in a potentiometer circuit
  • Parameterisation with the WIKAsoft-TT configuration software and electrical connection via quick connector magWIK
  • Connection terminals also accessible from the outside
  • Accuracy < 0.2 K (< 0,36 °F) / 0.1 %
Datasheet
User Manual

  • TÜV certified SIL version for protection systems developed per IEC 61508 (option)
  • Operation in safety applications to SIL 2 (single instrument) and SIL 3 (redundant configuration)
  • Configurable with almost all soft- and hardware tools
  • Universal for the connection of 1 or 2 sensors
    • Resistance thermometer, resistance sensor (up to 2 x 3-wire)
    • Thermocouple, mV sensor
    • Potentiometer
  • Signalling in accordance with NAMUR NE43, sensor monitoring in accordance with NE89, EMC in accordance with NE21, self-monitoring and diagnostics of field instruments in accordance with NE107
Datenblatt
Datenblatt

  • Versions for Pt100 / Pt1000 or thermocouples
  • Output 0 ... 10 V, 3-wire
  • Error signalling in the event of sensor break
  • High accuracy
  • Compact and value for money
Datasheet
Bedienungsanleitung

Digital transmitter to be built into own equipment

  • Type: Digital
  • Input: RTD
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel

Digital transmitter to be built into own equipment

  • Type: Digital
  • Input: RTD
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel

  • For the connection of all standard thermocouples
  • High accuracy
  • Parameterisation with the WIKAsoft-TT configuration software and electrical connection via quick connector magWIK
  • Connection terminals also accessible from the outside
  • EMC stability in compliance with the latest standard (EN 61326-2-3:2013)
Datasheet
User Manual

  • TÜV certified SIL version for protection systems developed per IEC 61508 (option)
  • Operation in safety applications to SIL 2 (single instrument) and SIL 3 (redundant configuration)
  • Configurable with almost all soft- and hardware tools
  • Universal for the connection of 1 or 2 sensors
    - Resistance thermometer, resistance sensor
    - Thermocouple, mV sensor
    - Potentiometer
  • Signalling in accordance with NAMUR NE43, sensorbreak detection in accordance with NE89, EMC in accordance with NE21

Datasheet
User Manual

The 3-digit indicator IMH-1U was designed as a multifunctional transmitter for the top hat rail mounting, for the measuring of voltage, current, temperature and frequency. The configuration happens via three front keys or via the optional PC software PM-TOOL. Optional the indicator can be equipped with a sensor supply, an analog output, 4 switching points, a Bluetooth interface, a data logger and interfaces RS232/RS485 (with Modbus protocol).

Datasheet
User Manual

  • temperature and voltage transmitter
  • RTD, thermocouple or milivotage input
  • output signal 4-20 mA
  • RS-485 / Modbus RTU
  • peaks detection function
  • free selection of characteristics
  • free data reading and configuration software S-Config
  • DIN rail mounting
Datenblatt
Bedienungsanleitung


DIN-Rail Temperature Transducers

A DIN-rail temperature transducer converts the signal from a temperature sensor — such as an RTD (e.g., Pt100) or a thermocouple — into a standardized output signal (commonly 4 … 20 mA or 0 … 10 V). This allows reliable and interference-resistant transmission of temperature measurements to controllers, recorders or control systems. Galvanic isolation between the sensor input and the output ensures robust signal quality and operational safety.

These transducers are typically designed as compact DIN-rail modules, making them easy to mount in control cabinets — space-saving, modular and organized. Many devices support universal sensor inputs (RTD, thermocouple, resistance, mV or voltage), allow flexible configuration, linearization and feature diagnostics (e.g., sensor break detection). This makes them a cornerstone in industrial temperature measurement and process automation.

Questions & Answers on DIN-Rail Temperature Transducers

What is a DIN-rail temperature transducer?

A DIN-rail temperature transducer is a module that converts a temperature sensor signal into a standardized analog output signal, suitable for process control and automation systems.

Which sensor types can be connected?

Common inputs are RTDs (e.g., Pt100/Pt1000), thermocouples, or resistance/voltage signals — many transducers are universal and support a variety of sensor types.

What output signals are provided?

Typically analog standard signals, such as 4 … 20 mA or 0 … 10 V, compatible with PLCs, controllers or monitoring equipment.

Why is galvanic isolation used?

Galvanic isolation prevents ground loops, potential differences and interference — ensuring stable, interference-free signal transmission.

How is the device installed?

The transducer is mounted on a DIN rail, facilitating a compact, modular and tidy installation inside control cabinets.

Are DIN-rail transducers flexible in terms of sensor types?

Yes — many support multiple types of sensors and input signals, making them adaptable for a wide range of temperature measurement tasks.

Can temperature signals be transmitted over long distances?

Yes — by using standard output signals (e.g., 4…20 mA), reliable transmission over long cable runs is possible with minimal signal degradation.

Do such transducers detect sensor errors?

Many offer diagnostics such as sensor break or short-circuit detection, enabling reliable fault indication via the output signal.

Where are DIN-rail temperature transducers typically used?

In industrial automation, HVAC systems, water/wastewater treatment, energy and environmental systems — anywhere temperature measurements must be reliably integrated into control or monitoring systems.

What are the advantages compared to direct sensor wiring?

More stable measurement signals, reduced susceptibility to interference, galvanic isolation, easy integration in control cabinets and compatibility with standard control systems.

Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.