• Measuring ranges from 0 … 0.05 to 0 … 1,000 bar
  • Non-linearity 0.25 % or 0.5 %
  • Output 4 ... 20 mA, DC 0 ... 10 V, DC 0 ... 5 V and others
  • Electrical connection: Angular connector form A and C, circular connector M12 x 1, cable outlet 2 m
  • Process connection G ¼ A DIN 3852-E, ¼ NPT and others
Datasheet
User Manual

  • CSA and FM approved as “explosionproof” for class I, div. 1 hazardous areas
  • ATEX approved as “flameproof enclosure” for II 2 G Ex d II C
  • Current or voltage output
  • Designed for harsh ambient conditions
  • Low-power version available as an option
Datasheet
User Manual

  • High number of load cycles due to patented design
  • Exchangeable process connection in case of an hair line crack
  • Suitable for highly dynamic pressure due to diaphragm protection system
  • Reduced recalibration costs due to excellent long term stability
Datasheet
User Manual

  • Measuring ranges from 0 ... 0.1 to 0 ... 6,000 bar [0 ... 3 to 0 ... 15,000 psi]
  • Approved for use in hazardous areas, e.g. ATEX, IECEx, FM and CSA
Datasheet
User Manual

  • Measuring ranges from 0 … 6 to 0 … 16 bar [0 ... 100 to 0 ... 200 psi] and from 0 … 200 to 0 … 400 bar [0 ... 3,000 to 0 ... 5,000 psi]
  • Output signals 4 … 20 mA, DC 0 … 10 V, DC 0 … 5 V, DC 1 ... 5 V, DC 0.5 … 4.5 V ratiometric
  • Oxygen clean in accordance with international standards
  • Available in four levels of cleanliness
  • Three packaging variants
Datasheet
User Manual

  • Measuring ranges from 0 ... 6 to 0 ... 1,000 bar [0 ... 500 to 0 ... 15,000 psi]
  • Current and voltage outputs
  • Ingress protection IP65 or IP67
  • Wetted parts and case from stainless steel
  • Vacuum-tight
Datasheet
User Manual

  • For extreme operating conditions
  • Compact and robust design
  • Diagnostic function (option)
  • Signal clamping (option)
  • Customer-specific modifications possible
Datasheet
User Manual

  • Measuring ranges from 0 ... 6 bar to 0 ... 600 bar
  • Non-linearity 0.5 %
  • Standard industrial signals
  • Electrical connection: Angular connector form A and C, circular connector M12 x 1, Metri-Pack series 150, cable outlet 2 m unshielded or shielded
  • Many internationally customary process connections
Datasheet
User Manual

  • Accuracy 0.1 %, without additional temperature error in a range of 10 ... 60 °C
  • Optional accuracy of 0.05 % (full scale) available
  • Fast measuring rates up to 1 kHz
  • Analogue, USB and CANopen® output signals available
  • On-site calibration possible using product software
Datasheet
User Manual

  • Wetted parts from stainless steel
  • Resistant to all common refrigerants
  • Special case design for the best possible condensation tightness
  • Private labelling possible
Datasheet
User Manual

  • Measuring ranges from 0 ... 0.1 to 0 ... 1,000 bar
  • Non-linearity 0.2 % of span (BFSL)
  • Output signals: 4 ... 20 mA, DC 0 ... 10 V, DC 0 ... 5 V and others
  • Electrical connections: Angular connector form A, circular connector M12 x 1, various cable outlets and others
  • Zero point and span adjustable via internal potentiometer
Not available anymore! Successor models are: S-20 and A-10
Datasheet
User Manual

  • High-quality product
  • Many configurations possible
  • Flush process connection
  • Large stocks for short delivery times
  • Vacuum-tight
Datasheet
User Manual

  • High-accuracy pressure measurement 0.15 % RSS
  • Excellent long-term stability
  • Signal noise cancellation and shielding
  • Vacuum-referenced pressure measurement
  • Active temperature compensation
Datasheet
User Manual

  • Recording interval adjustable from 1 ms ... 10 s
  • Measuring ranges from 0 … 25 mbar to 0 … 1,000 bar (0 ... 0.4 psi to 0 ... 14,500 psi)
  • Accuracy: 0.2 %, optionally 0.1 % (incl. calibration certificate)
  • No external voltage supply required
  • Software for recording of the measured value, calibration and evaluation
Datasheet

  • Metrological accuracy: 0.025 % FS on the 4 ... 20 mA output
  • Measuring range: 25 mbar ... 1,001 bar [10 inH₂O ... 15,015 psi]
  • Voltage supply from DC 15 ... 28 V
  • Temperature compensation: -20 ... +75 °C [-4 ... +167 °F]
  • NAMUR NE43-compliant
Datasheet
User Manual

  • Accuracy up to 0.01 % IS-50
  • Measuring range from -1 ... 400 bar (-15 ... 6,000 psi)
  • RS-232 or RS-485 interface
  • Compact design
Datasheet
User Manual

  • Accuracy up to 0.025 % IS-50
  • Measuring range from -1 ... +400 bar (-15 ... +6,000 psi)
  • Output mode 250 Hz (4 ms) response time
  • Streaming output mode in IEEE-754 format
Datasheet
User Manual

  • Accuracy: 0.008 % IS-33
  • Measuring range: 25 mbar ... 1,001 bar [10 inH2O ... 15,015 psi]
  • Temperature compensation: 0 ... 50 °C [32 ... 122 °F]
  • RS-232 or RS-485 communication
  • Rugged and compact design
Datasheet
User Manual


WIKA Pressure Sensors – Analog Precision for Industry & Process

WIKA pressure sensors/transmitters deliver reliable, continuous readings via 4–20 mA or 0–10 V signals—ideal for gauge, absolute and differential pressure from vacuum to high pressure. Depending on the application, they use ceramic, piezoresistive, thin-film or capacitive sensing elements. Variants with 316L stainless steel, optional Hastelloy®/Monel® and suitable seals (FKM, EPDM, PTFE/FFKM) ensure high resistance—even in harsh environments.

ICS Schneider Messtechnik supports you with sizing (range, accuracy), correct materials/seals, the right process connection and protective measures (snubber, cooling element, diaphragm seal). On request, we provide ISO/DAkkS calibration and integrate your measuring points into a PLC/DCS or optional IIoT stack.



FAQ on WIKA Pressure Sensors (Analog)

Selection, signals, accuracy, installation, media, EMC and documentation—concise and practical.

Which output signals are available?

SignalTypeBenefitTypical use
4–20 mACurrent, 2-wireHighly EMC-robust, long cablesIndustrial/process
0–10 VVoltage, 3-wireSimple evaluationBuilding/HVAC, OEM
RatiometricVoltageLow power demandEmbedded/OEM

How do I select the right measuring range?

Rule of thumb: working pressure × 1.3–2.0. With pulsation/spikes, choose a higher range or add a snubber/orifice.

What accuracies are typical?

Depending on model ±0.25…1.0% FS. For QA/test, select variants with a tighter Total Error Band (TEB).

Which process connections does WIKA offer?

ConnectionStandardNote
G 1/4, G 1/2ISO 228 (BSPP)Industrial standard
¼″ / ½″ NPTASMETapered, self-sealing
M20×1.5ISO metricEU process industry
Hygienic (Tri-Clamp/Varivent®)EHEDGWith/without diaphragm seal

What should I consider for media compatibility?

316L covers many media; for highly corrosive media use Hastelloy®/Monel® and select suitable seals (FKM/EPDM/PTFE/FFKM). Always check compatibility tables.

How do I protect the sensor against pressure spikes?

Use snubbers/orifices, capillaries or a diaphragm seal. Additionally enable measurement damping/filtering in the controller/PLC.

What supply voltage do analog transmitters need?

Typically 12–30 V DC. Observe allowable ripple and ensure sufficient current headroom (4–20 mA loops).

What is the correct wiring?

  • 4–20 mA (2-wire): wire +/− in series through the analog input.
  • 0–10 V (3-wire): +Ub, GND, Signal separately; avoid ground loops.

Which EMC measures are recommended?

Use shielded, twisted-pair cable; ground the shield on one side; ensure equipotential bonding; route power and signal separately.

What temperatures are permitted?

Model/datasheet dependent. For hot media use a cooling element/siphon or remote mount; consider temperature effects (TEB).

Are options available for hazardous or hygienic applications?

Yes—selected WIKA models feature ATEX/IECEx approvals and hygienic versions (EHEDG). Please inquire with your requirements.

How often should I calibrate?

Recommendation: annually; QA/safety loops semi-annually/quarterly or after overload/service. ISO/DAkkS certificates available.

Can I connect analog WIKA sensors to IIoT?

Yes—via analog inputs of an edge gateway (publishing via MQTT/HTTPS to SCADA/cloud). For pure bus integration, WIKA also offers variants with IO-Link/HART/Modbus.

What are common error sources and fixes?

  • Range too small → overload → select higher range
  • Pulsation → noise/wear → add snubber/damping
  • Wrong seal → leakage → verify material compatibility
  • EMC/ground loops → offset/drift → optimize shielding/grounding

Do you support selection & documentation?

Yes—from media/material check, sizing/drawings and calibration to commissioning, including test reports and BOMs.

Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.