iCT1 Current and Voltage Transformer test set


iCT1 – CT/VT Test Set is the NEW and most advanced portable equipment capable to test current, voltage and combined transformers.
With the low voltage method, known as “DC method”, iCT1 is able to test Current Transformers with a very high saturation voltage, up to 30 kV, in a complete safety mode. Quick and easy to use tool, iCT1 allows to perform tests in one shot without changing the connection to the CT, thanks to the integrated 5-TAP Switchbox.

Datasheet

Key features

  • Designed to test Current, Voltage and Combined Transformers
  • Time saving testing: only 1 set up connection to perform all the tests
  • Main tests performed: Ratio & Phase Error, Excitation, Resistance, Accuracy, Burden
  • 5-TAP integrated Switchbox describing the behavior of the CT
  • Able to test CT with saturation voltage up to 2kV and till 30kV applying DC indirect method
  • Integrated Demagnetizer
  • CT Explorer function: able to find the nameplate data of the CT
  • Compact and lightweight
  • Patented technology

 

Tests performed on Current transformer

  • Turn ratio and polarity voltage mode
  • Burden secondary side
  • Excitation curve
  • Excitation curve DC method
  • Winding/burden resistance
  • ALF / ISF
  • Leackage current AC
  • Accuracy test
  • CT explorer
  • Demagnetizer

 

Tests performed on Voltage transformer

  • Ratio
  • Ratio electronics
  • Burden
  • No load current








Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    iCT1 Current and Voltage Transformer test set

    iCT1 – CT/VT Test Set is the NEW and most advanced portable equipment capable to test current, voltage and combined transformers.
    With the low voltage method, known as “DC method”, iCT1 is able to test Current Transformers with a very high saturation voltage, up to 30 kV, in a complete safety mode. Quick and easy to use tool, iCT1 allows to perform tests in one shot without changing the connection to the CT, thanks to the integrated 5-TAP Switchbox.

    Datasheet

    Key features

    • Designed to test Current, Voltage and Combined Transformers
    • Time saving testing: only 1 set up connection to perform all the tests
    • Main tests performed: Ratio & Phase Error, Excitation, Resistance, Accuracy, Burden
    • 5-TAP integrated Switchbox describing the behavior of the CT
    • Able to test CT with saturation voltage up to 2kV and till 30kV applying DC indirect method
    • Integrated Demagnetizer
    • CT Explorer function: able to find the nameplate data of the CT
    • Compact and lightweight
    • Patented technology

     

    Tests performed on Current transformer

    • Turn ratio and polarity voltage mode
    • Burden secondary side
    • Excitation curve
    • Excitation curve DC method
    • Winding/burden resistance
    • ALF / ISF
    • Leackage current AC
    • Accuracy test
    • CT explorer
    • Demagnetizer

     

    Tests performed on Voltage transformer

    • Ratio
    • Ratio electronics
    • Burden
    • No load current








    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.