Back to page

ICS Schneider Messtechnik
ICS Schneider Messtechnik – Kontakt

Digital indicator IM3 AC voltage/current – high voltage 96 x 48 mm

Digital indicator IM3 AC voltage/current – high voltage 96 x 48 mm
  • 5-digit digital panel meter in 96 × 48 mm format
  • Suitable for high AC voltage and AC current signals as true RMS (TRMS)
  • Measuring ranges available for 300 VAC, 600 VAC, 1 AAC and 5 AAC
  • Easy-to-read display with 14 mm digit height in red, green, orange or blue
  • Front-panel operation via keypad with IP65 protection rating
  • With digital input for control functions such as hold, tare, display change or alarm triggering
  • Optionally available with analog outputs, relay outputs or PhotoMOS outputs
  • Galvanically isolated RS232 or RS485 interface available
  • Extensive software functions such as min./max. memory, alarm control, power and energy measurement as well as mathematical functions
Datasheet
User Manual

The IM3-1VR5B.0H04.S70xD is a 5-digit meter for measuring high AC voltage signals TRMS up to 600 VAC and a visual limit value monitoring via the display. The configuration happens via 4 front keys or via the optional PC-software PM-TOOL. Optional two analog outputs, one digital input, interfaces RS232/RS485 and up to 8 switching points are available. A direct limit value adjustment in operating mode and many selectable software functions complete the modern device concept.

Housing 96 x 48 mm
Display 5-digit
14 mm digit height
Colour: red, green, orange or blue display
Range displayed -19999 to 99999
Operation front panel keyboard protection class IP65
Input High voltage inputs true RMS
300 VAC, 600 VAC, 1 AAC, 5 AAC
Digital input: <2.4V OFF, >10V ON, max. 30 VDC
Analogue Output 2 analog outputs
0/4-20 mA / 0-10 VDC / 16 Bit
Switch point 2 or 4 relays (change-over contacts)
250 V / 5 AAC, 30 V / 5 ADC
or 8 PhotoMos outputs (NOC) 30 V / 0.4 A AC/DC
Interface RS232 or RS485 galvanic isolated
Alternatively to analog output 2
Power supply 100-240 VAC 50/60 Hz / DC +/- 10%
Sensor supply –
Software properties
  • min/max-memory with adjustable permanent display
  • 30 additional adjustable supporting points
  • display flashing at threshold value exceedance/undercut
  • zero-key for triggering of Hold, Tara, display change, setpoint setting, alarm actuator
  • flexible alarm system with adjustable delay times
  • power and energy measurement at constant voltage
  • mathematical functions like reciprocal value, square root, squaring and rounding
  • constant setting/setpoint setting
  • sliding averaging
  • brightness control via parameter or front keys
  • programming interlock via access code