Back to page

ICS Schneider Messtechnik
ICS Schneider Messtechnik – Kontakt

EMT432-2 / EMT463-2 - melt pressure transmitter

EMT432-2 / EMT463-2 - melt pressure transmitter
  • Intrinsically safe EMT4XX 2 melt pressure transmitter for pressure and temperature measurement
  • ATEX-certified for hazardous area applications
  • Integrated thermocouple for simultaneous temperature measurement
  • 4–20 mA two-wire output signal
  • Pressure ranges from 0–17 bar to 0–2,000 bar
  • Media temperatures up to 400 °C
  • Flexible connection between sensing stem and electronics housing

Datasheet

Dynisco EMT4XX 2 Intrinsically Safe Melt Pressure Transmitter with Temperature Measurement

The Dynisco EMT4XX 2 series is based on proven TDT technology and is specifically designed for pressure measurement in hazardous areas. The integrated two-wire amplifier converts the process pressure into a noise-immune 4–20 mA output signal, ensuring reliable signal transmission even over long distances.

An integrated thermocouple allows simultaneous temperature measurement directly at the process medium. The flexible connection between the sensing stem and electronics housing improves thermal isolation and simplifies installation. The series features a flush diaphragm, integrated electronic calibration functionality and ATEX certification for use in potentially explosive atmospheres.

Technical Specifications
Pressure Ranges 0–17 bar to 0–2,000 bar
Temperature Measurement Integrated Type J thermocouple
Accuracy EMT432 2 ±0.5% FSO (up to 50 bar ±1% FSO)
Accuracy EMT463 2 ±1% FSO
Repeatability EMT432 2 ±0.1% FSO (up to 50 bar)
Repeatability EMT463 2 ±0.2% FSO
Resolution Infinite
Maximum Overpressure 2× pressure range; for 1,000 and 1,400 bar ranges max. 1,750 bar; for 2,000 bar range max. 2,450 bar
Burst Pressure 6× pressure range, max. 3,000 bar
Wetted Material 15-5 PH stainless steel, material no. 1.4545, DyMax™ coated
Sensing Element Four-arm strain gauge bridge
Output Signal 4–20 mA
Supply Voltage 15–28 VDC
Current Consumption < 20 mA
Zero Adjustment -2% to +10% of full scale
Internal Calibration Point 80% of full scale ±10%
Load Resistance 750 Ω at 28 VDC, 145 Ω at 15 VDC
Insulation Resistance 1,000 MΩ at 50 VDC
Maximum Diaphragm Temperature 400 °C
Maximum Housing Temperature 80 °C (T1–T4), 75 °C (T5)
ATEX Approval II 2 G Ex ia IIC T5 up to 75 °C and II2G EEx ia IIC T1-T4 up to 80 °C