Back to page

ICS Schneider Messtechnik
ICS Schneider Messtechnik – Kontakt

Level Transmitter IP139

Level Transmitter IP139
  • Dry gold plated ceramic sensor
  • Smallest measuring range: 0…100 mbar / 0…1 mH2O
  • Largest measuring range: 0…20 bar / 0…200 mH2O
  • Accuracy ≤ 0,3%
  • High overload capability
  • Rugged design
  • Analog output: 4…20 mA, 2-wires
  • Optionally integrated PT100 / PT1000 sensor for temperature measurement
Datasheet
User Manual

Description

The ceramic capacitive measuring principle of the IP139 level transmitter is used in a wide range of industrial applications. In combination with a high-quality stainless steel housing, the sensor is suitable for almost all liquids and gases.  The  sensor  is  commonly  used in  pumping and  lifting applications,  where it guarantees long-term stable measurement.  Our  modular  design  concept  provides a wide  variety of  products.  Feel  free to contact us if you need a customization that is not listed in this datasheet.

 

Applications:

  • Gaseous media
  • Water
  • Waste water
  • Well / Deep well
  • Lifting equipment
  • Oil and fuel
  • Viscous and pasty media
  • Aggressive media

 

Technical data:

Measuring ranges Smallest measuring range: 0…100 mbar / 1 mH2O
Largest measuring range: 0…20 bar / 200 mH2O
Analog output 4…20 mA, 2-wires
Power supply 20 mA output: 9…30 V DC
Accuracy ≤ ± 0,3 % FS @ 25 °C
Long term stability ≤ ± 0,3 % FS / Year
Response time 200 ms – others on request
Swich-on time < 1 s
Temperature coefficient Zero: ≤ ± 0,015 % FS / Kelvin
≤ 200 mbar ≤ 0,025 % FS / Year
Span: ≤ ± 0,015 % FS / Kelvin
≤ 200 mbar ≤ 0,025 % FS / Year
Medium temperature -25…80 °C
Surrounding temperature -25…80 °C
Storage temperature -40…85 °C
Short-circuit resistance Permanent
Reverse polarity protection Protection against reverse polarity, but no function
Electromagnetic compatibility Interference emissions and immunity acc. to EN 61326
Wetted materials Housing: Stainless steel 1.4404
Sensor: Ceramic Al2O3
Process seal: FPM (Viton), EPDM, FFKM (Chemraz / Kalrez)
Protection type IP 68
Weight Approx. 550 g with 5m cable

Technical data

Output signal

4: 4…20 mA 2-wire, T: 4…20 mA 2-wire and PT100 3-wire, F: 4…20 mA 2-wire and PT1000 3-wire

Measuring range

00: 0…100 mbar / 0…10 kPa, 0…1 mWS*, Y3: 0…150 mbar / 0…15 kPa, 0…1,5 mWS, 01: 0…160 mbar / 0…16 kPa, 0…1,6 mWS, B1: 0…200 mbar / 0…20 kPa, 0…2 mWS, 02: 0…250 mbar / 0…25 kPa, 0…2,5 mWS, X5: 0…300 mbar / 0…30 kPa, 0…3 mWS, X1: 0…350 mbar / 0…35 kPa, 0…3,5 mWS, 03: 0…400 mbar / 0…40 kPa, 0…4 mWS, B7: 0…500 mbar / 0…50 kPa, 0…5 mWS, 04: 0…600 mbar / 0…60 kPa, 0…6 mWS, 05: 0…1 bar / 0…100 kPa, 0…10 mWS, 06: 0…1,6 bar / 0…160 kPa, 0…16 mWS, B3: 0…2 bar / 0…200 kPa, 0…20 mWS, 07: 0…2,5 bar / 0…250 kPa, 0…25 mWS, 08: 0…4 bar / 0…400 kPa, 0…40 mWS, F1: 0…5 bar / 0…500 kPa, 0…50 mWS, 09: 0…6 bar / 0…600 kPa, 0…60 mWS, 10: 0…10 bar / 0…1 MPa, 0…100 mWS, 11: 0…16 bar / 0…1,6 MPa, 0…160 mWS, B5: 0…20 bar / 0…2 MPa, 0…200 mWS, 99: Special Measuring Range

Material housing / process seal

1: Edelstahl 1.4404, S: 1.4404 Serto-Verschraubung am Kabel (auf Anfrage)

Cable length

002: 2 m Kabel, 005: 5 m Kabel, 010: 10 m Kabel, 050: 50 m Kabel, 100: 100 m Kabel, (Sonderlängen in Meter auf Anfrage)

Cable material

0: PE cable (PT100/PT1000 not possible), 2: PUR cable, 4: HDPE cable, 6: FEP cable

Cable type

0: Unshielded (standard), 1: Shielded

Process seal

1: FPM (Viton), standard, 3: EPDM rubber, 5: FFKM (Chemraz / Kalrez)