  • Rugged fixed gas detectors designed for industrial and hazardous environments
  • Multiple models (Type 1–6 and Xsafe) for different sensor and enclosure configurations
  • Supports electrochemical, pellistor and thermal conductivity sensor technologies
  • Up to IP65 protection rating for reliable operation in harsh conditions
  • Operating temperature range from –40 °C to +150 °C depending on model
  • Standard 4–20 mA output for easy integration into gas detection systems
  • Certified for hazardous areas including ATEX, IECEx and UL
  • Flexible installation options with multiple cable entry configurations

Datasheet

Overview

Intrinsically Safe (I.S.) or Flameproof (Exd) versions are available, with case options comprising high-grade alloy, stainless steel or chemically resistant GRN polymer. Certifications include IECEx, ATEX, UL and GOST-R.

Low cost of ownership

  • Designed for easy installation and maintenance – keeps costs down
  • Three junction box options – designed to make replacement of sensors and sinters extremely simple. Spare sensors simply plug-in
  • Many spare parts are common to all Xgard models – keeps spares holding requirements to a minimum

Flexible installation options

  • Designed for either wall or ceiling mounting – no need for additional brackets
  • Can accommodate M20, 1/2″ NPT or 3/4″ NPT cable glands – suits all site requirements
  • High temperature models are available for hot environments (up to 150oc)
  • Accessories are available for duct mounting and sampling applications as well as remote gassing – simple sensor checking

Wide range of sensors

  • Poison resistant pellistors, for all flammable detection needs including hydrocarbons, hydrogen, ammonia, jet fuel, leaded petrol and vapours containing halogens
  • Electrochemical sensors are used to detect a vast range of toxic gases and oxygen
  • Thermal conductivity sensors are available to monitor % volume concentrations of gases

Rugged and reliable

  • Manufactured using a choice of three materials: glass reinforced nylon, highly durable aluminium with a tough polyester coating, or 316 stainless steel for ultimate corrosion resistance – designed to operate even in the harshest environments
  • Spray deflectors and weatherproof caps are available for use in areas subject to regular wash-downs, or offshore environments
  • All models have been validated to the functional safety standard IEC 61508 (SIL 1 to SIL 3)

 

Specifications

Type 1 Type 2 Type 3 Type 4 Type 5 Type 6
Size 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches) 195 x 166 x 111mm (7.6 x 6.5 x 4.3 inches) 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches)
Weight Nylon: 0.5 kgAlloy: 1kg (2.2lbs)316 S/S: 3.1kg (6.8lbs) Aluminium: 1kg (2.2lbs)Stainless steel: 3.1kg (6.8lbs) 1.5 kg (3.3lbs) Aluminium: 1kg (2.2lbs) Stainless steel: 3.1kg (6.8lbs)
Enclosure material ATEX certified: Glass reinforced nylon or 316 S/SUL Certified: Aluminium or 316 S/S Aluminium or 316 Stainless Steel Aluminium Aluminium or 316 Stainless Steel
Ingress protection IP65 IP54 IP65
Cable entries 1 x M20, 1/2 “NPT or 3/4 NPT* on right-side
Terminations 0.5 to 2.5mm2
Sensor type Electrochemical Catalytic bead 316 S/S sensor housing with catalytic beads Catalytic bead Thermal conductivity
Operating temperature -40 to +50 °C
(-40 to 122 °F)
(sensor dependant)
-20 to +50°C (-4 to 122°F) -40 to +80°C
(-40 to 176°F)
-20 to +150°C (-4 to 302°F) -40 to +55°C (-40 to 131°F) +10 to +55°C (50 to 301°F)
Humidity 10 to 95% RH non-condensing 0-99% RH non-condensing 0-90% RH
Repeatability Zero drift <2% FSD (Typical)<2% FSD per Month (Typical)
Response time T90 <15s OxygenT90 <30s to 120s Toxic(sensor dependant) T90 <15s (Typical)
Operating voltage 8-30V dc 2.0V dc +/- 0.1V (Typical) 10-30V dc
Power requirements 24mA maximum 300mA (Typical) 50mA at 24V dc 1.2W
Electrical output 2- wire 4-20mA (current sink) 3- wire mV bridgeTypical signal: 12-15mV/ %LEL CH4 3- wire mV bridgeTypical signal: >10mV/%LEL CH4 3- wire 4-20mA (current sink or source)
Approvals ATEX: II 1 G
Exia IIC T4 Ga
(Tamb -40 to +55°C)
UL/cUL: Class I, Div. 1
Groups A, B, C, D
IECEx
EAC
ATEX: II 2GD
Exd IIC T6 Gb (Tamb -40 to +50°C)
UL: Class I, Div. 1
Groups B, C, D
IECEx
EAC
ATEX: II 2 GD
Exd IIC T4 Gb
(Tamb -40 to +80°C)
Exd IIC T6 Gb (Tamb -40 to +50°C)
Ex tb IIIC
T180°C Db
UL: Class I, Div. 1
Groups B, C, D
IECEx
EAC
ATEX: II 2 GDExd IIC T3 Gb (Tamb -40 to +150°C) ATEX: II 2 GDExd IIC T6 Gb (Tamb -40 to +50°C)
Exd IIC T4 Gb (Tamb -40 to +80°C)
Ex tb IIIC
T180°C Db
UL: Class I, Div. 1
Groups B, C, D
IECEx
EAC
EMC compliance EN 50270       FCC Part 15    ICES- 003

*3/4 ” cable entry only available on aluminium juntion boxes.