MDT435F / MDT467F - melt pressure transmitter

MDT435F / MDT467F - melt pressure transmitter
  • 2-wire melt pressure transmitter with 4…20 mA output signal
  • MDT435F model with 0.5 % accuracy and MDT467F model with 1.0 % accuracy
  • “Auto-Zero” function for zero adjustment directly at the transducer or remotely
  • High noise immunity, even with unshielded connection cables
  • Small sensing head for restricted installation spaces
  • Integrated electronic range calibration with 80 % of full scale
  • 2-wire amplifier converts process pressure into a proportional 4…20 mA signal
  • Media temperature up to 400 °C
  • Pressure ranges from 0…35 bar to 0…2000 bar
  • Defined fault signal behavior according to NAMUR NE 43
Datasheet

Dynisco MDT435F / MDT467F Melt Pressure Transmitters

The Dynisco MDT435F / MDT467F Series includes new 2-wire melt pressure transmitters with 4…20 mA output signal for use in critical environments with high interference potential. The devices are designed so that the current signal can be transmitted reliably over long distances, even when unshielded connection cables are used.

A key feature of the series is the “Auto-Zero” function. Zero adjustment can be initiated directly in the field via a push button on the transducer or remotely from the control room or central control system. The applied process pressure is converted by the integrated 2-wire amplifier into a proportional 4…20 mA output signal.

The MDT435F and MDT467F models feature a special short sensing head with 1/2″-20 UNF thread and a flexible, partly free capillary to the amplifier housing. This makes them especially suitable for applications with limited installation space. The series also includes integrated electronic range calibration and defined fault signal behavior according to NAMUR NE 43.

Type 2-wire melt pressure transmitter with 4…20 mA output
Series Dynisco MDT435F / MDT467F Series
Models MDT435F and MDT467F
Application Melt pressure measurement in critical environments with high interference and restricted installation space
Output signal 2-wire 4…20 mA
Pressure range 0…35 bar to 0…2000 bar
Accuracy MDT435F ±0.5 % F.S.; up to 50 bar ±1 % F.S.
Accuracy MDT467F ±1 % F.S.
Repeatability MDT435F ±0.1 % F.S.; up to 50 bar ±0.2 % F.S.
Repeatability MDT467F ±0.2 % F.S.
Resolution Infinite
Measuring system 4-arm strain gauge
Supply voltage 12…36 VDC
Internal calibration point 80 % of full scale ±1 %
Range calibration By calibration value 80 % F.S.
Zero adjustment Via “Auto-Zero” adjustment function
Auto-Zero zero adjustment Locally by push button on the transducer or remotely from control room / central control system by shorting the “CAL-” and “GND” terminals
Load resistance 1200 Ω at 36 VDC; 500 Ω at 24 VDC
Insulation resistance 1000 MΩ at 50 VDC
Signal output in fault condition Failure signal level according to NAMUR NE 43: ≤3.6 mA or ≥21 mA
Maximum overload 2 × pressure range; for 1000 and 1400 bar range max. 1750 bar; for 2000 bar range max. 2450 bar
Burst pressure 6 × pressure range, max. 3000 bar
Material in contact with media 15-5 PH SST, material no. 1.4545, DyMax™ coated
Max. diaphragm temperature 400 °C
Diaphragm zero shift due to temperature change MDT435F < 0.2 bar / 10 °C; MDT467F < 0.4 bar / 10 °C
Max. housing temperature 85 °C
Housing zero shift due to temperature change ±0.2 % F.S. / 10 °C
Sensitivity shift due to temperature change MDT435F ±0.1 % F.S. / 10 °C; up to 50 bar ±0.2 % F.S. / 10 °C; MDT467F ±0.3 % F.S. / 10 °C
Sensing head Short pressure sensing head for restricted installation spaces
Process connection 1/2″-20 UNF thread
Connection Flexible, partly free capillary to the amplifier housing
Key features 2-wire technology, Auto-Zero function, high noise immunity, unshielded connection possible, integrated electronic calibration, NAMUR NE 43 fault signal