Back to page

ICS Schneider Messtechnik
ICS Schneider Messtechnik – Kontakt

SPX4232 - Massedrucktransmitter

SPX4232 - Massedrucktransmitter
  • Smart 4…20 mA pressure transmitters for hazardous locations
  • SPX 4-Series for general melt pressure and process pressure measurement
  • Optional HART™ communication available
  • 4…20 mA loop-powered output for direct connection to DCS or PLC
  • Accuracy down to ±0.25 % available, depending on model and pressure range
  • Wide selection of pressure ranges and configurations
  • Rangeability up to 6:1 turndown
  • Configurations available for use in hazardous locations
  • CE, ATEX / IECEx intrinsically safe approvals as well as SIL2 and PL “c” certifications available
  • Optional thermocouple or RTD configurations for melt temperature measurement

Datasheet

Dynisco SPX 4-Series Pressure Transmitters

The Dynisco SPX 4-Series includes smart 4…20 mA pressure transmitters for general melt pressure measurement and process pressure measurement in hazardous locations. These amplified transmitters are designed for direct connection to distributed control systems, PLCs, computers and similar high-level control devices. In many applications, this eliminates the need for external signal conditioning.

The SPX 4-Series is available with a variety of process and electrical connections for different installation requirements. Depending on the model, accuracies down to ±0.25 % are available. The pressure transmitters provide precise and repeatable measurements, a wide selection of pressure ranges and rangeability up to 6:1 turndown.

Configurations for hazardous locations are available with ATEX / IECEx intrinsically safe approval. Optional HART™ communication enables remote configuration and parameter adjustment. In addition, optional thermocouple or RTD configurations are available to provide melt temperature measurement in addition to pressure measurement.

Type Smart 4…20 mA pressure transmitter
Series Dynisco SPX 4-Series
Application General melt pressure measurement, process pressure measurement and hazardous location applications
Output 4…20 mA, with optional HART™
Input voltage 16…36 VDC standard; 16…30 VDC for ATEX IS versions
Accuracy SPX4222 ±0.25 % for pressure ranges ≥1,500 psi; ±0.50 % for pressure ranges <1,500 psi
Accuracy SPX4232 ±0.25 % for pressure ranges ≥1,500 psi; ±0.50 % for pressure ranges <1,500 psi
Accuracy SPX4352 ±0.25 % for pressure ranges ≥1,500 psi; ±0.50 % for pressure ranges <1,500 psi
Accuracy SPX4502 ±0.50 %
Accuracy SPX4622 ±0.50 %
Accuracy SPX4672 ±0.50 %
Repeatability ±0.1 %
Rangeability 6:1 turndown
Over pressure 2 × FSO or 35,000 psi, whichever is less; 1.2 × FSO for 35,000…72,500 psi for certain versions
Zero balance adjustment range -40 % to +10 %; -80 % to +20 % for FSO < 500 psi
Load resistance 500 Ω at 24 VDC; 1,000 Ω at 36 VDC
Electronics ambient temperature 70 °F / 20 °C
Electronics operating temperature -20…185 °F / -29…85 °C
Electronics compensated temperature range 0…150 °F / -18…65 °C
Diaphragm temperature 750 °F / 400 °C maximum; SPX4502 model limited to 600 °F / 315 °C
Electronics zero shift SPX4222 0.01 % FS / °F max. or 0.02 % FS / °C max.
Electronics zero shift SPX4232 0.01 % FS / °F max. or 0.02 % FS / °C max.
Electronics zero shift SPX4352 0.01 % FS / °F max. or 0.02 % FS / °C max.
Electronics zero shift SPX4502 0.01 % FS / °F max. or 0.02 % FS / °C max.
Electronics zero shift SPX4622 0.05 % FS / °F max. or 0.10 % FS / °C max.
Electronics zero shift SPX4672 0.05 % FS / °F max. or 0.10 % FS / °C max.
Electronics span shift SPX4222 0.01 % FS / °F max. or 0.02 % FS / °C max.
Electronics span shift SPX4232 0.01 % FS / °F max. or 0.02 % FS / °C max.
Electronics span shift SPX4352 0.01 % FS / °F max. or 0.02 % FS / °C max.
Electronics span shift SPX4502 0.01 % FS / °F max. or 0.02 % FS / °C max.
Electronics span shift SPX4622 0.02 % FS / °F max. or 0.04 % FS / °C max.
Electronics span shift SPX4672 0.02 % FS / °F max. or 0.04 % FS / °C max.
Snout zero shift SPX4222 15 psi / 100 °F typical or 27 psi / 100 °C
Snout zero shift SPX4232 15 psi / 100 °F typical or 27 psi / 100 °C
Snout zero shift SPX4352 15 psi / 100 °F typical or 27 psi / 100 °C
Snout zero shift SPX4502 1 psi / 100 °F typical from 75…450 °F; 2 psi / 100 °F typical from 450…600 °F
Snout zero shift SPX4622 25 psi / 100 °F typical or 45 psi / 100 °C
Snout zero shift SPX4672 25 psi / 100 °F typical or 45 psi / 100 °C
Mounting torque SPX4222 500 inch-lbf max.
Mounting torque SPX4232 50 inch-lbf max.
Mounting torque SPX4352 500 inch-lbf max.
Mounting torque SPX4502 350 inch-lbf max.
Mounting torque SPX4622 500 inch-lbf max.
Mounting torque SPX4672 500 inch-lbf max.
Standard wetted parts DyMax® coated 15-5 PH stainless steel
Approvals ATEX / IECEx Intrinsically Safe
Safety certifications SIL2 certified for pressure output; PL “c” certified for relay output
Additional approvals Additional approvals available, consult factory
Key features 4…20 mA output, HART™ option, intrinsically safe versions, direct connection to DCS or PLC, precise and repeatable pressure measurement