Rough, dust-laden, and corrosive – the challenges in the construction material and cement production are as complex and multifaceted as the materials being processed. Ensuring workplace safety, especially when dealing with corrosive or abrasion-intensive substances, is as critical as the flexibility to adapt to new, environmentally friendly manufacturing processes.
The industry faces the task of developing efficient and sustainable production methods that not only secure the quality and durability of the end products but also minimize environmental impacts. Introducing technologies to reduce the CO2 footprint and improve energy efficiency are key elements on the path to a greener future. At the same time, the industry must implement innovative solutions for dust control and handling of heavy materials to make the workplace safer and healthier.
The digital pressure transmitter which features remote safety handling - developed according to IEC61508 standards for SIL2/3. Accuracy: 0,065 %
Datasheet |
User Manual |
The digital "high performance" pressure transmitter which features remote safety handling and is ready for digitalization - developed according to IEC61508 standards for SIL2/3. Accuracy: 0,04 %
Datasheet |
User Manual |
SITRANS LC300 is an inverse frequency shift capacitance continuous level transmitter for liquids and solids or liquid interface applications. Materials with low or high dielectric properties are accurately measured and Active-Shield technology helps in ignoring the effects of buildup near vessel nozzle.
Datasheet |
User Manual |
SITRANS LR560 is the first choice and easiest-to-use solids radar transmitter on the market. With a high frequency of W band (78 GHz), 4-degree narrow beam, and short wavelength, it performs reliably on solids material from practically any installation location.
Datasheet |
User Manual |
User Manual |
User Manual |
SITRANS LR460 is for challenging solids applications. For extremely low dielectric, low density powders, the 25 GHz SITRANS LR460 is the preferred solution. Featuring a horn antenna with an 8-degree beam, this 4-wire FMCW device has proven itself in thousands of applications.
Datasheet |
User Manual |
SITRANS LPS200 is a rotary paddle switch for point level detection in bulk solids. Ideal for point level or safety backup applications with SIL 2 and motor failsafe detection.
Datasheet |
User Manual |
SITRANS FS290 flexible, versatile, practical
- Check metering, temporary and test measurements
- Compensation of flow disturbances through the anomaly compensation
- Long battery life, simple battery replacement
- Measurement accuracy of 1% under good conditions
Datasheet |
The MAG 5000 and 6000 are transmitters engineered for high performance, easy installation, commissioning and maintenance. The transmitters evaluate the signals from the SITRANS F M sensors type MAG 1100, MAG 1100 F, MAG 3100, MAG 3100 P and MAG 5100 W.
Transmitter types:
- MAG 5000: Max. measuring error ± 0.4 % ± 1 mm/s (incl. sensor)
- MAG 6000: Max. measuring error ± 0.2 % ± 1 mm/s (incl. sensor, see also sensor specifications) and with additional features such as: “plug & play” add-on bus modules; integrated batch functions.
Datasheet |
User Manual |
SITRANS FM MAG 6000i Electromagnetic flow transmitter, works with sensors of type MAG 1100, MAG 3100 and MAG 5100W. Suitable for volume flow measurement of liquids (conductive), die-cast aluminium enclosure. . Remote transmitter Die cast aluminium Processing code Standard transmitter: 18-90 V DC, 115-220 V AC 50/60 Hz Standard sensor: FM Class I, Div 2, CSA Class I,Div 2 Local Display No Communication . Metric
Datasheet |
User Manual |
SITRANS FM Transmag 911/E Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 1000 (1/2" to 40"), AC-excited. Suitable for volume flow measurement of liquids (conductive), for use in heavy-duty applications like pulp & paper stock over 3%, mining slurries with magnetic particles.
Datasheet |
User Manual |
- Flexible installation - IP68 (NEMA 6P) compliance allows installation in soil or underwater
- Low pressure loss and excellent leak detection
- Optimized lining allows good metering performance with low flow
- No maintenance - no moving parts and battery life of up to 15 years
- Maximum freedom in installations with low inlet and outlet distances
- Approved for MID-001 without defined length of inlet and outlet
- Remote access possible - running flow data through optional wireless 3G / UMTS communication module
Datasheet |
User Manual |
SITRANS FM MAG 1100 is a sensor in stainless steel with highly resistant liners and electrodes which fit even the most extreme process media.
Datasheet |
User Manual |
SITRANS FM MAG 3100 is an electromagnetic flow sensor with a large variety of liners, electrode material and with grounding electrodes as standard, all this ensures a perfect fit for almost every flow application.
Datasheet |
User Manual |
SITRANS FM MAG 5100 W Electromagnetic flow sensor, flanged, diameter DN 15 to DN 1200 (1/2" to 48"). Suitable for volume flow measurement of liquids (conductive) , for applications in water abstraction, water & wastewater treatment, water distribution networks, custody transfer metering.
Datasheet |
User Manual |