Sensitive goods can be damaged during transport by excessively high or low temperatures, humidity, condensation, shocks or improper handling. The damage is often visible upon delivery, but its exact cause remains unclear.
Transport data loggers accompany the shipment and record the relevant environmental conditions throughout the entire transport route. This makes it possible to determine when a limit violation occurred, how long it lasted and whether strong shocks were recorded at the same time.
Depending on the application, a simple temperature data logger may be sufficient. For electronics, machine components, pharmaceutical products, food or works of art, relative humidity and shock exposure may also be crucial.
However, the significance of the recording does not depend solely on the instrument. The measuring range, measurement interval, limit values, start time and position of the logger inside the package must match the specific transport task.
This article explains how transport monitoring should be planned, which measured variables are required and how the data can be assessed correctly during incoming-goods inspection, quality assurance and complaint handling.
Table of contents
- What a transport data logger does
- Distinguishing temperature, humidity and shock
- Which goods should be monitored particularly closely
- Documenting temperature and the cold chain
- Considering humidity, dew point and condensation
- Assessing shocks and impact events
- Defining appropriate limit values
- Selecting the measurement interval and recording duration
- Positioning the logger correctly inside the package
- When several data loggers are required
- Preparing the logger and starting the transport
- Correctly evaluating the PDF report and measured data
- Using measured data for complaints
- Typical transport-monitoring errors
- Practical example: Damaged electronic component
- Which measuring instruments / products are suitable?
- Conclusion
- Frequently asked questions about transport data loggers
What a transport data logger does
A transport data logger stores measured values together with the date and time. This creates a chronological record of the conditions to which the goods were exposed during shipping, intermediate storage and delivery.
Depending on the instrument, the following variables may be recorded:
- temperature
- relative humidity
- shock or acceleration
- where applicable, air pressure, inclination, light or location
A logger does not prevent damage. However, it creates transparency and can provide early evidence that specified transport conditions were not maintained.
The recording can support, for example:
- release or rejection of a delivery
- assessment of an interrupted cold chain
- investigation of moisture and corrosion damage
- detection of severe impacts or improper handling
- optimisation of packaging and the transport route
- documentation for customers and logistics service providers
For a reliable assessment, it must be defined before shipment which deviation is considered critical and which measures will follow if a limit is violated.
Distinguishing temperature, humidity and shock
| Measured variable | Typical hazard | Suitable applications |
|---|---|---|
| Temperature | Spoilage, material changes, freezing or overheating | Pharmaceuticals, food, chemicals, batteries and temperature-sensitive electronics |
| Relative humidity | Corrosion, moisture damage, swelling, mould or condensation | Electronics, machinery, packaging materials, art and hygroscopic products |
| Shock | Breakage, deformation, loose components or damage to sensitive mechanisms | Machinery, measuring instruments, optics, electronics, glass and sensitive assemblies |
The measured variables should not be considered in isolation. Cold goods may develop condensation after the packaging is opened in a warm and humid environment. A severe impact may only be damaging if the packaging was also inadequately cushioned.
A combined logger simplifies chronological correlation. It can show, for example, whether a shock event occurred during transhipment and whether the temperature subsequently increased more rapidly because the packaging had been damaged.
Which goods should be monitored particularly closely
Transport monitoring is particularly useful when a deviation could result in high product value losses, safety risks or complex complaint procedures.
Typical applications include:
- medicines, vaccines and diagnostic products
- chilled and frozen food
- electronic assemblies and semiconductors
- precision measuring instruments and optical systems
- machinery, drives and sensitive bearings
- works of art, musical instruments and historical objects
- chemicals, paints and temperature-sensitive raw materials
- lithium batteries and energy-storage systems
Permanent recording may be disproportionate for standardised, non-critical goods. For valuable individual shipments or quality-critical series deliveries, however, logger data can prevent substantial consequential costs.
Documenting temperature and the cold chain
For chilled products, it is not sufficient to check only the temperature at dispatch and delivery. An interim rise in temperature may already have subsided by the time the goods are received.
The data logger displays the complete history and helps answer important questions:
- When was the permissible range exceeded?
- What was the highest or lowest temperature reached?
- How long did the deviation last?
- Did it occur once or several times?
- Did the temperature subsequently recover slowly or abruptly?
Not every brief limit violation automatically makes the goods unusable. The assessment depends on the product, permissible deviation duration and quality requirements.
Dry-ice shipments require a data logger whose permissible temperature range covers the actual temperatures encountered. A standard logger for conventional chilled transport may be outside its specification or fail at approximately −80 °C.
Considering humidity, dew point and condensation
Relative humidity describes how saturated the air is with water vapour at the current temperature. It is therefore always temperature-dependent.
If the temperature falls while the water content remains constant, relative humidity rises. If the dew point is undershot, condensation may form on the goods, metal components or inside the packaging.
Humidity monitoring is particularly relevant for:
- uncoated electronics
- bare metal components
- hygroscopic materials
- paper, cardboard and wooden packaging
- optical components
- works of art and cultural assets
A high humidity value must be assessed together with the temperature, duration and packaging design. A brief peak when a container is opened may require a different assessment from several days of high humidity inside sealed packaging.
If goods are unpacked immediately in a warm and humid hall after cold transport, condensation may only occur after the actual transport has ended. This transition should also be considered in the process.
Assessing shocks and impact events
A shock data logger records accelerations that may occur when the package is dropped, struck, set down hard or involved in a collision. The measured value is frequently stated as a multiple of gravitational acceleration in g.
However, a high g value does not automatically mean that the goods have been damaged. The following factors are also decisive:
- duration and shape of the shock pulse
- direction of the load
- sensitivity of the product
- installation position of the logger
- packaging and cushioning
- mass and structural design of the goods
A logger installed on the outside of a wooden crate may record different values from an instrument attached directly to the product. The packaging may attenuate, amplify or alter the shock over time.
Shock and continuous vibration are also not the same. Transport over a poor road surface may generate moderate vibrations over a long period, while dropping the package causes a brief, very high acceleration pulse.
The defined shock limits should therefore be derived from product tests, manufacturer specifications or a qualified packaging analysis.
Defining appropriate limit values
Limit values must not be selected solely according to the available setting range of the data logger. They must match the product, packaging and transport-release criteria.
For temperature and humidity, upper and lower limits as well as permissible delay times may be required. A brief exceedance during loading may need to be assessed differently from a persistent deviation during the main transport stage.
For shock measurements, the axis may also be relevant in addition to the limit value. A product may be significantly more sensitive in the vertical direction than along its longitudinal axis.
The following should be documented before shipment:
- permissible measuring range
- warning and rejection limits
- permissible deviation duration, where applicable
- shock limit and relevant axes
- assessment and escalation procedure
Without predefined criteria, discussions frequently arise after transport regarding whether a recorded event was actually critical.
Selecting the measurement interval and recording duration
The measurement interval determines the temporal resolution of the temperature and humidity history.
A short interval captures rapid changes more effectively, but generates more data and may reduce battery life. A long interval is suitable for lengthy transports with slowly changing conditions, but may overlook brief events.
The following factors should be considered:
- expected transport duration
- thermal inertia of the goods and packaging
- speed of possible temperature changes
- available measurement-data memory
- battery life
- required chronological correlation with transhipment points
Measurement intervals in the range of minutes are often sufficient for temperature and humidity. Shock events, however, require much faster, event-based detection. A combined logger therefore does not necessarily process all measured variables using the same recording principle.
An additional time reserve should also be planned. Delays caused by customs clearance, intermediate storage or return transport must not result in the memory or battery being exhausted before the actual end of transport.
Positioning the logger correctly inside the package
The position of the data logger has a considerable influence on the measured results.
Possible positions for temperature measurements include:
- close to the most sensitive product
- in the centre of a pallet
- close to the outer wall or door of a transport container
- in the upper or lower section of a container
- between individual product layers
A logger placed directly next to a cooling element may record its local temperature rather than the temperature of the goods. An instrument positioned directly against the container wall, on the other hand, reacts more quickly to external temperatures than the more thermally inert packaged goods in the centre.
For humidity measurements, there must be sufficient air exchange with the atmosphere being monitored. The logger must not be completely enclosed in vapour-tight film if the humidity outside this film is to be assessed.
For shock measurements, the instrument must be firmly attached to the package or product. A loose logger may move around inside the packaging and record its own impacts, which are not representative of the load applied to the goods.
The position and orientation of the logger should be photographed or documented in the shipping documents.
When several data loggers are required
A single logger shows only the conditions at its position. In large shipments, considerable differences may occur within the transport container.
Several loggers are particularly useful for:
- large pallets or machinery crates
- containers with uneven air circulation
- shipments with several temperature zones
- critical products with a high value
- qualification of a new packaging or transport concept
- comparison between the product core and the edge of the packaging
For chilled transport, one logger may be positioned close to the door and another in the centre of the load. The first detects short-term heat ingress when the door is opened, while the second better represents the actual product temperature.
The number and positions should be derived from a risk analysis or previous transport qualification.
Preparing the logger and starting the transport
Before being placed inside the packaging, the data logger should be fully configured and checked.
- Identify the instrument: Assign the serial number clearly to the shipment.
- Check the time: Verify the date, time and, where applicable, time zone.
- Configure the limits: Enter product-specific temperature, humidity and shock limits.
- Select the measurement interval: Consider the recording duration and temporal resolution.
- Check the battery: Ensure sufficient reserve for the transport and possible delays.
- Check the function: Verify the display, start function and memory status.
- Position the logger: Document its position and attachment.
- Start the recording: Clearly confirm the start and record the dispatch time.
A start delay may be useful if the logger is prepared during packaging but the actual transport monitoring is not intended to begin until later.
When several loggers are used, identical names, time bases and limit values should be used unless the measuring task requires different settings.
Correctly evaluating the PDF report and measured data
Plug-and-play loggers frequently create a PDF report automatically when connected to a computer. This allows the recipient to inspect the shipment quickly without installing special software.
A typical report contains:
- instrument and shipment identification
- start and end time
- configured limit values
- minimum, maximum and average values
- limit violations
- graphical measured-value history
- shock events or an event overview
A simple alarm indication is usually not sufficient when a deviation has occurred. The time, duration and magnitude of the exceedance must be considered for the assessment.
Correlation with the transport events is also important. Shipping documents, handover times, GPS data or scans from the logistics service provider help identify the transport stage during which the deviation occurred.
The original data should be archived without modification. Additional comments and assessments can be created for internal reports without overwriting the original measurement file.
Using measured data for complaints
Data loggers can make an important contribution to determining the cause of damage. However, they do not automatically provide complete proof that a specific party is responsible.
For reliable complaint handling, the following should also be available:
- clear assignment of the logger to the shipment
- documented position and attachment
- traceable start and end times
- calibration status or measuring-equipment monitoring
- photographs of the packaging and goods
- handover and transport times
- agreed transport conditions and limit values
A high shock value may show that considerable mechanical stress occurred. Whether this exact event caused the damage must be assessed on the basis of the packaging, product sensitivity and damage pattern.
A temperature exceedance can likewise be documented without automatically proving that the goods are unusable. Product release remains a professional quality decision.
Typical transport-monitoring errors
| Error | Possible consequence | Better approach |
|---|---|---|
| Logger positioned directly next to the cooling element | The measured value does not represent the product temperature | Attach the logger close to the critical goods |
| Measurement interval too long | Brief temperature deviations remain undetected | Adapt the interval to the dynamics and risk |
| Shock logger lies loose in the packaging | Its own movements distort the recorded events | Secure the logger firmly to the product or package |
| Limit values discussed only after transport | No unambiguous release decision is possible | Define the assessment criteria before shipment |
| Insufficient battery reserve | Recording ends if transport is delayed | Allow an adequate time reserve |
| Only one logger used in a large shipment | Local temperature or humidity differences remain unknown | Use several representative measuring positions |
| Logger position not documented | The measured values are difficult to interpret later | Photograph the position and assign it to the shipment |
| Alarm indication assessed without detailed evaluation | Brief and long-term deviations are treated in the same way | Analyse the history, magnitude and duration |
Practical example: Damaged electronic component
A sensitive electronic assembly is shipped to a customer in a padded transport crate. On delivery, a connector is damaged, while the external packaging shows only minor signs of damage.
A combined transport data logger was firmly mounted on the inner base plate of the crate. It recorded temperature, relative humidity and shocks.
Temperature and humidity remained within the agreed ranges throughout the transport. However, the logger shows a significant shock event in the vertical direction during the night before delivery.
Using the transport times, the event can be assigned to a transhipment warehouse. Additional photographs show slight deformation at a lower corner of the crate.
The analysis alone does not prove that the connector was damaged by this specific event. However, the shock direction, damage pattern and deformation of the packaging create a consistent overall picture.
For future transports, the assembly is additionally supported and the impact protection on the underside is improved. During a subsequent test shipment, significantly lower acceleration values are measured at the product despite comparable handling.
The example shows that transport loggers are not only useful for complaints. The measured values can also be used to improve the packaging and logistics process systematically.
Which measuring instruments / products are suitable?
The humidity data loggers category contains instruments for recording temperature and relative humidity during transport, storage and climate monitoring.
Additional instruments for temperature, pressure, electrical quantities and various monitoring tasks are available in the data loggers and universal measuring instruments category.
testo 184 G1 for temperature, humidity and shock
The testo 184 G1 combines the recording of temperature, relative humidity and shock events in one instrument.
It is particularly suitable for electronics, sensitive machinery, pharmaceutical products, food and other goods for which both climatic and mechanical stresses must be documented.
A PDF report is generated automatically when the instrument is connected to a computer. This allows the data to be evaluated at the destination without installing software in advance.
testo 184 H1 for temperature and humidity
The testo 184 H1 is designed for combined transport monitoring of temperature and relative humidity.
It is suitable for long-term applications in which shocks do not need to be monitored but humidity fluctuations and condensation risks play an important role.
testo 184 T1 to T3 for temperature-only monitoring
The temperature data loggers of the testo 184 T series are available for conventional cold chains and temperature-sensitive goods.
The testo 184 T1 is suitable for time-limited transports with simple start, alarm and PDF functions. Further versions offer larger memories or longer operating periods.
testo 184 T4 for dry-ice shipments
The testo 184 T4 is intended for temperature monitoring during dry-ice shipments down to −80 °C.
It is therefore particularly suitable for pharmaceutical and biotechnology products transported at very low temperatures.
Selecting the appropriate transport logger
At least the required measured variables, permissible temperature and humidity ranges, transport duration, measurement interval, shock limit, packaging type and required report format are needed for selection.
ICS Schneider Messtechnik assists with selecting a suitable data logger, defining appropriate measuring positions and configuring limit values and measurement intervals.
Conclusion: Meaningful transport data begins with proper planning
Transport data loggers document the temperature, humidity and shock conditions to which goods were exposed during shipment and intermediate storage.
For simple cold chains, a temperature data logger is often sufficient. For electronics, machinery, works of art or particularly sensitive products, humidity and shock exposure may be equally important.
The position of the logger must represent the actual exposure of the goods. An instrument placed next to a cooling element, against the container wall or loose inside the packaging can produce misleading results.
Limit values and assessment criteria should be defined before shipment. Only then can a clear decision be made during incoming-goods inspection as to whether the delivery should be released, investigated or rejected.
An automatically generated PDF report facilitates rapid inspection. For complaints, the logger assignment, position, calibration status, condition of the packaging and transport times must also be documented.
When used correctly, transport loggers do more than preserve evidence. They also provide valuable information for optimising the packaging, cooling concept and logistics process.
Frequently asked questions about transport data loggers
Which variables can a transport data logger measure?
Depending on the instrument, temperature, relative humidity, shock, acceleration, air pressure, light, inclination or location can be recorded.
When is a combined logger for temperature, humidity and shock useful?
When both climatic and mechanical stresses may influence product quality, for example with electronics, machinery, pharmaceuticals or works of art.
Where should a temperature data logger be positioned inside the package?
As close as possible to the sensitive product and at a position that represents its actual temperature. The logger should not be placed directly next to a cooling element or against the outer packaging wall unless that specific area is to be monitored.
How should a shock data logger be attached?
It should be firmly attached to the product, internal mounting structure or package. A loose instrument may record additional, non-representative impacts.
Which measurement interval is suitable for transport?
This depends on the transport duration, thermal inertia and risk. Intervals in the range of minutes are often suitable for temperature and humidity, while shocks are detected much faster or on an event basis.
What does a limit violation mean?
The configured upper or lower limit has been exceeded. Whether the goods have been damaged or rendered unusable must be assessed on the basis of the magnitude, duration and product specification.
Does a high shock value automatically indicate transport damage?
No. The shock duration, direction, packaging, product strength and damage pattern must also be considered.
Can a data logger serve as evidence in a complaint?
It provides important objective measured data. For a reliable assessment, however, the logger must be assigned clearly to the shipment and its position, time base and calibration status must be documented.
Why is humidity important when transporting electronics?
High humidity and condensation can cause corrosion, leakage currents and damage to electronic assemblies.
How can an interruption of the cold chain be identified?
The temperature history shows when the permissible range was exceeded, which extreme temperature was reached and how long the deviation lasted.
Are several loggers required for a large pallet?
Several measuring positions are useful for large or thermally non-uniform shipments. This allows differences between the edge, centre, door side and product core to be identified.
What must be considered regarding battery life?
The operating time must cover the planned transport, including delays, intermediate storage and possible return shipment.
Which information does ICS Schneider require for product selection?
The required measured variables, temperature and humidity range, transport duration, desired measurement interval, shock limits, packaging type, number of measuring points and requirements concerning the PDF report, software and calibration are needed.