The new DPI610 Series

  • Improved pump design for ease of use and speed
  • Rugged, stable design for the toughest and most challenging environments with a backlit high-contrast display
  • Vacuum up to 35 bar/500 psi/3.5 MPa pneumatically
  • Built-in barometer for accurate absolute pressures
  • Up to 1000 bar/15000 psi/100 MPa hydraulic pressures
  • Large, user-friendly and intuitive interface includes both physical buttons and a touchscreen, allowing use with or without gloves
  • HART configurator in all versions
  • Total 1-year uncertainty of 0.025% of full scale value over a temperature range of -10°C to +50°C
  • DPI610E retains the comprehensive electrical capabilities of the original DPI 610 series, but with better accuracy and simplified connections
  • Ergonomic, iconic handle design
  • Hand-tight, quick-connect pressure adapters and hoses mean no tools are needed up to 1000 bar
  • Enhanced documentation capabilities
  • Hazardous area version (intrinsically safe) available
  • Compatible with external pressure and temperature probes (PM700E & RTD probe)
  • Improved battery life of over 24 hours with 2 hours charging time

DPI610E Hydraulic Commercial With Strap Over Head RT RGB
DPI610E Hydraulic Commercial With Strap Over Head RT RGB b
DPI610E Hydraulic Commercial With Strap Over Head RT RGB

Pneumatic Pressure

 Abbreviation Pressure Range NLHR (24 h) (% of End Value) -10 to 50 °C Total Measurement Uncertainty (1 year) (% of End Value) -10 to 50 °C
 Relative Pressure -10 to 50 °C Pseudo Absolute Pressure (1) 0 to 50 °C
 03G 350 mbar / 5 psi / 35 kPa 0.02 0.047 0.186
 05G 1 bar / 15 psi / 100 kPa 0.0185 0.041 0.077
 07G 2 bar / 30 psi / 200 kPa 0.018 0.025 0.040
 08G 3.5 bar / 50 psi / 350 kPa 0.018 0.025 0.031
 10G 7 bar / 100 psi / 700 kPa 0.018 0.020 0.027
 11G 10 bar / 150 psi / 1,000 kPa 0.018 0.020 0.027
 13G 20 bar / 300 psi / 2 MPa 0.018 0.020 0.027
 14G 35 bar / 500 psi / 3.5 MPa 0.018 0.020 0.027
DPI610E Hydraulic Commercial With Strap Over Head RT RGB b

Hydraulic Pressure

 Abbreviation Pressure Range NLHR (24 h) (% of Full Scale) -10 to 50 °C Total Measurement Uncertainty (1 Year) (% of Full Scale) -10 to 50 °C
 Relative Pressure -10 to 50 °C Absolute Pressure Overpressure
 16A 70 bar / 1,000 psi / 7 MPa 0.018 0.063 0.063 0.025
 16G 70 bar / 1,000 psi / 7 MPa 0.018 0.025 0.025 0.025
 165A 100 bar / 1,500 psi / 10 MPa 0.018 0.063 0.063 0.025
 165G 100 bar / 1,500 psi / 10 MPa 0.018 0.025 0.025 0.025
 17A 135 bar / 2,000 psi / 13.5 MPa 0.018 0.063 0.063 0.025
 17G 135 bar / 2,000 psi / 13.5 MPa 0.018 0.025 0.025 0.025
 18A 200 bar / 3,000 psi / 20 MPa 0.018 0.063 0.063 0.025
 18G 200 bar / 3,000 psi / 20 MPa 0.018 0.025 0.025 0.025
 22A 350 bar / 5,000 psi / 35 MPa 0.018 0.063 0.063 0.025
 22G 700 bar / 10,000 psi / 70 MPa 0.018 0.025 0.025 0.025
 23A 1,000 bar / 15,000 psi / 100 MPa 0.018 0.063 0.063 0.025

Note 1: For pseudo-absolute pressure, a relative pressure sensor is used in conjunction with the integrated barometer to provide an absolute pressure reading. The total measurement uncertainty is given as % of full scale of the relative pressure range. The total measurement uncertainty of the barometer (24 h) is < 0.5 mbar, with a drift of < 0.33 mbar/year (typical).

Specified Accuracy

 Pressure Range Standard Accuracy High Accuracy Premium Accuracy
 NLH&R Total Measurement Uncertainty NLH&R Total Measurement Uncertainty NLH&R Total Measurement Uncertainty
-10 to 50 °C (14 to 122 °F)
 (% of FS) (% of FS) (% of FS) (% of FS) (% of FS) (% of FS)
 Relative/Differential Pressure Sensors
 25 mbar 0.3 0.348 n/a n/a n/a n/a
 70 mbar 0.1 0.121 n/a n/a n/a n/a
 200 mbar 0.08 0.1 n/a n/a n/a n/a
 350 mbar to 1 bar 0.08 0.1 0.04 0.05 n/a n/a
 2 bar to 200 bar 0.08 0.1 0.04 0.05 0.018 0.025
 Absolute Pressure Sensors
 750 to 1,150 mbar (barometric) 0.08 0.1 0.04 0.075 n/a n/a
 350 mbar and 700 mbar 0.08 0.1 0.04 0.075 n/a n/a
 1 bar to 7 bar 0.08 0.1 0.04 0.075 n/a n/a
 10 bar to 1,400 bar 0.08 0.1 0.04 0.075 0.018 0.063

Notes:
1. NLH&R = Non-linearity, Hysteresis, and Repeatability.
2. Total measurement uncertainty includes drift over 1 year and calibration measurement uncertainty. For absolute pressure ranges of 350 mbar to 7 bar, typical values are given – for maximum values add 0.045% of FS for standard accuracy and 0.055% of FS for high accuracy.
For absolute pressure ranges of 10 bar and above, maximum values are given above.

External Features of the DPI 610E

The illustration shows a pneumatic device for hazardous areas.

BHCS39207 GR Druck DPI610 Datasheet R11 (5) 4 1

Pressure Generation

The innovative design of the DPI 610E pressure generation system, combined with carefully selected components, ensures simple and efficient pressure generation as well as precise control. With enhanced pressure generation features, the DPI 610E offers higher pressures and volumes with market-leading pneumatic pressure ranges from 95% vacuum up to 35 bar/500 psi/3.5 MPa. A simple selector switch allows for easy switching from vacuum to pressure, and the required pressure can be generated with just a few pump strokes. Fine adjustments can be made using the integrated volume controller, and decreasing pressure calibration points are achieved with the precision-controlled vent valve.

The pneumatic version is supplied with a dirt separator to prevent contamination of the device itself and the system to be tested by dirt, deposits, and moisture. The pneumatic pressure range is -0.95 to 35 bar/500 psi/3.5 MPa (relative pressure). An internal overpressure valve safely vents into the interior of the housing to protect the internal pressure sensor. The relief pressure is factory set for the ordered sensor/pressure range.

The hydraulic version features an external 100 ml tank, making the hydraulic oil or water level always visible, a suction pump to remove air from the connected system, and a booster to quickly and easily generate pressure up to 1,000 bar/15,000 psi/100 MPa.

  • The range for hydraulic pressure generation is 1,000 bar/15,000 psi/100 MPa (absolute pressure).
  • An internal overpressure valve safely vents back into the tank to protect the internal pressure sensor. The relief pressure is factory-set for the ordered sensor/pressure range.

A zero pressure correction is available for relative/differential pressure sensors.

Use any pressure units for your specific application: mbar, bar, Pa (N/m2), hPa, kPa, MPa, mmHg at 0°C, cmHg at 0°C, mHg at 0°C, inHg at 0°C, kg/cm2, kg/m2, mmH2O at 20°C, cmH2O at 20°C, mH2O at 20°C, torr, atm, psi, lb/ft2, inH2O at 4°C, inH2O at 20°C, inH2O at 60°F, ftH2O at 20°C, ftH2O at 4°C, ftH2O at 60°F, mmH2O at 4°C, cmH2O at 4°C, mH2O at 4°C, custom

Pneumatic versions feature an integrated barometer that allows the use of relative pressure and absolute pressure sensors in pseudo ranges. For hydraulic versions, we offer an overpressure measurement mode for absolute pressure sensors (10 bar and higher).

 

Pressure Measurement Tools

All test results can be saved and exported to a PC.

It is used to determine if there is a leakage in the system by measuring the pressure change over a specified period. The leakage test can also be conducted using the RTD sensor to record temperature changes over time. Customizable stabilization/waiting time (up to 60 minutes) and test periods (1 second to 480 minutes) with a live countdown timer.

Used to check whether safety or relief valves operate as intended when the pressure exceeds safe pressure limits, and whether they return to the normal closed position when the pressure returns within normal operating pressure limits.

This function checks the response of pressure switches when they reach their set trip points and their reset when the pressure is back within normal operating pressure limits. Additionally, at the end of each test, the hysteresis value is calculated.

Options for Measurement Procedures

Scaling

Allows the scaling of measured values to custom units with user-defined unit labels. For example, mA can be expressed as a percentage. Flow correction enables the scaling of outputs from differential flow meters.

Filter

Provides a filtered measurement by displaying a moving average of the last 10 measurements. Delivers a more stable measurement value in noisy measurements. Can be applied to all types of measurements.

Tare (Taring)

Temporary zero offset function for 0 to 100% of the full scale value by subtracting the current measured value from subsequent measurements. Can be applied to all types of measurements.

Alarm

User-adjustable alarms with visual warnings (bell icon, pressure reading, and flashing backlight). Can be applied to all types of measurements.

Min/Max/Mean (Minimum/Maximum/Mean)

Provides instant minimum, maximum, and mean values for each type of measurement that is recorded and displayed.

Flow (Throughput)

Performs a square root calculation for the pressure measurement value.

Decentralized Plug & Play Sensor Range

dpi610e sensorsortimentengl

PM 700E External Decentralized Pressure Sensors

A single DPI 610E can be used with any number of external sensors, as all sensors contain their calibration data and are supplied with a 2.9-meter (9.5 feet) cable. Available pressure ranges according to the table:

Availability of PM 700E External Decentralized Pressure Sensors

 Type Standard Accuracy 0.1% (-1) High Accuracy 0.05% (-2) Premium Accuracy 0.025% (-3)
25 mbar / 10 inH2O / 2.5 kPa G, L
70 mbar / 1 psi / 7 kPa G, L
200 mbar / 3 psi / 20 kPa G, L
350 mbar / 5 psi / 35 kPa G, A, L G, L
700 mbar / 10 psi / 70 kPa G, A, L G, L
1 bar / 15 psi / 100 kPa G, A, L G, A, L
750 to 1,150 mbar / 11 to 17 psi / 75 to 115 kPa (barometric) B B
2 bar / 30 psi / 200 kPa G, A, L G, A, L G
3.5 bar / 50 psi / 350 kPa G, A G, A G
7 bar / 100 psi / 700 kPa G, A G, A
10 bar / 150 psi / 1,000 kPa G, A G, A
20 bar / 300 psi / 2 MPa G, A G, A
35 bar / 500 psi / 3.5 MPa G, A G, A
70 bar / 1,000 psi / 7 MPa A A A
100 bar / 1,500 psi / 10 MPa A A A
135 bar / 2,000 psi / 13.5 MPa A A A
200 bar / 3,000 psi / 20 MPa A A A
350 bar / 5,000 psi / 35 MPa A A A
700 bar / 10,000 psi / 70 MPa A A A
1,000 bar / 15,000 psi / 100 MPa A A A
1,400 bar / 20,000 psi / 140 MPa A A A

G = Gauge Pressure    L = Differential Pressure    A = Absolute Pressure    B = Barometric

Option for Negative Calibration (OP1) (Relative Pressure Sensors)

 Pressure Range End Value Sensors with Standard and High Accuracy Sensors with Premium Accuracy
25 mbar to 1 bar/10 inH2O to 15 psi/100 kPa to 2.5 kPa Standardly available up to the negative end value Not available
1 bar to 20 bar/15 psi to 300 psi/20 kPa to 2 MPa Available up to -1 bar as option OP1 Standardly available up to -1 bar gauge
35 bar to 200 bar/500 psi to 3,000 psi/3.5 MPa to 20 MPa Not available – calibrated up to 0 bar gauge Not available – calibrated up to 0 bar gauge

Note: All differential pressure sensors are standardly calibrated up to the negative end value (limited to -1 bar).

 

PM 700E External Decentralized Pressure Sensors

1 – Standard ±0.1% of FS total accuracy over -10 to 50 °C including NLH&R, drift over 1 year, and calibration measurement uncertainty

2 – High ±0.05% of FS total accuracy over -10 to 50 °C including NLH&R, drift over 1 year, and calibration measurement uncertainty

3 – Premium ±0.025% of FS total accuracy over -10 to 50 °C including NLH&R, drift over 1 year, and calibration measurement uncertainty

 

The external sensors are equipped with pressure connections as listed below:

  • P1 – G1/8 internal thread for direct sensor connection of the device, welded, non-removable (for pressure ranges up to 200 bar and below) with optional adapter:
  • P2 – G1/4 adapter with internal thread for the G1/8 internal thread connection of the devices
  • P3 – 1/8 NPT adapter with internal thread for the G1/8 internal thread connection of the devices
  • P4 – 1/4 NPT adapter with internal thread for the G1/8 internal thread connection of the devices
  • P5 – Quick connect adapter, supplied with G1/8 and 1/8 NPT adapters
  • P6 – 9/16 x 18 UNF with external thread for direct sensor connection of the device, welded, non-removable (required for ranges greater than/equal to 350 bar)

Note: To ensure the integrity of the pressure sensor, only fluids compatible according to the table above should be used.

 


Specified Accuracy

 Relative/Differential Pressure Sensors Standard Accuracy High Accuracy Premium Accuracy
NLH&R (% of FS) Total Measurement Uncertainty -10 to 50 °C (14 to 122 °F) (% of FS) NLH&R (% of FS) Total Measurement Uncertainty -10 to 50 °C (14 to 122 °F) (% of FS) NLH&R (% of FS) Total Measurement Uncertainty -10 to 50 °C (14 to 122 °F) (% of FS)
 Pressure Range
25 mbar 0.3 0.348 N/A N/A N/A N/A
70 mbar 0.1 0.21 0.08 0.15 N/A N/A
200 mbar 0.08 0.21 0.08 0.15 N/A N/A
350 mbar to 1 bar 0.08 0.21 0.08 0.15 N/A N/A
2 bar to 200 bar 0.04 0.1 0.04 0.05 0.018 0.025
 Absolute Pressure Sensors
750 to 1,150 mbar (barometric) 0.08 0.1 0.08 0.1 N/A N/A
350 mbar and 700 mbar 0.08 0.21 0.08 0.15 N/A N/A
1 bar to 7 bar 0.08 0.21 0.08 0.15 0.053 0.063
10 bar to 1,400 bar 0.08 0.21 0.08 0.15 0.053 0.063

1. NLH&R = Nonlinearity, Hysteresis, and Repeatability.
2. The total measurement uncertainty includes the drift over 1 year and the calibration uncertainty. For the absolute pressure ranges of 350 mbar to 7 bar, typical values are given – for maximum values add 0.045 % of FS for standard accuracy and 0.055 % of FS for high accuracy.
For absolute pressure ranges of 10 bar and above, the maximum values are given above.

Optional External RTD Temperature Interface/Probe

Allows users to perform plug & play temperature measurements, where units are displayed as resistance or temperature.

The pure interface option part number RTD-INTERFACE-485 for the DPI 610E-PC / DPI 610E-HC for safe areas or part number RTD-INTERFACE-IS for DPI 610E-SPC / DPI 610E-SHC for hazardous areas enables users to use their own PT100 RTD probe.

The RTD-INTERFACE comes with a field-wireable M12 connector, allowing users to connect their own RTD probes with free cable ends.

The probe option part number RTD-PROBE-485 for the DPI 610E-PC / DPI 610E-H for safe areas or part number RTD-PROBE-IS for the DPI 610E-SPC / DPI 610E-SHC for hazardous areas is supplied with the interface and a 15 cm (6-inch) Class A PT100 probe. All RTD-PROBE and RTD-INTERFACE models are supplied with a 2.9 m cable.

 

dpi610e messfühler

Specified Accuracy for RTD

  NLH&R ±1 °C (2 °F) for 24 h (Note 1) Total Measurement Uncertainty 10 to 30 °C (50 to 86 °F) for 1 Year (Note 2) Additional Deviation -10 to 10 °C (14 to 50 °F) to 30 to 50 °C (86 to 122 °F)
 0 to 400 Ω 0.012% of Reading + 0.005% of Span 0.015% of Reading + 0.006% of Span 0.001% of Span/°C
 Pt 100 – Measured Temperature Range -200 to 0 °C 0.017% of Reading + 0.1 °C Except PT100 Calibration Error
 Pt 100 – Measured Temperature Range 0 to 850 °C 0.0215% of Reading + 0.1 °C Except PT100 Calibration Error

Notes:
1. The NLH&R value includes the stability at ±2 °C for 24 hours at temperatures from 10 °C to 30 °C.
2. The total measurement uncertainty includes the drift over 1 year.


General Technical Data for RTD

 Temperature Measurement
 IO-RTD-PRB150 -50 °C to 200 °C (when used with a suitable extension cable)
 RTD-INTERFACE (Housing) -10 °C to 50 °C
 RTD-PROBE -10 °C to 50 °C when directly connected to RTD-INTERFACE
-25 °C to 75 °C when using the supplied cable
 SPECIAL RTD SENSORS (Not supplied by Druck) The resistance range of the RTD-INTERFACE with a suitable extension cable and appropriate sensor is 0 to 400 Ω, corresponding to -250 °C to +650 °C for a PT100 sensor.
 Dimensions
 IO-RTD-PRB150 RTD-PROBE Sensor Tip: Ø 6.35 x 150 mm
Total Sensor: Ø 15 x 200 mm
 RTD-INTERFACE Housing: Ø 34 x 72 mm Length
DPI610E Pneumatic Commercial Side 2 RT RGB
DPI610E Hydraulic Intrinsically Safe Side 1 RT RGB

Portable Calibrators from DRUCK

DPI705E DPI104 DPI802 DPI880 DPI611 DPI612 DPI620 GENii DPI610E
 Display Channels (simultaneous) 1 1 2 2 3 3 6 (Genii commercial) & 6 (Genii-IS) 2
 Self-contained Pressure Generation X X X X ✓ with PV62X base X
 Pressure Sensor Accuracy % FS 0.1 / 0.05 / 0.025% (-10 to 50°C) 0.05% (-10 to 50°C) 0.1 / 0.05% (10 to 30°C) 0.1 / 0.05% (10 to 30°C) 0.025% (-10 to 50°C) PM620 0.025% (-10 to 50°C) PM620 0.025% (-10 to 50°C) 0.025% (-10 to 50°C)
 Self-contained Pressure Sensor Fixed 0.025 to 700 bar Fixed 0.7 to 1400 bar Fixed 0.025 to 700 bar X Fixed -1 to 20 bar Modular PM620 0.025 to 1000 bar, PM620T 12 bar to 1000 bar via MC620 Modular PM620 0.025 to 1000 bar, PM620T 12 bar to 1000 bar Fixed 0.035 to 1000 bar FS
 External Pressure Sensors ✓ PM700E 0.025 to 1400 bar ✓ IDOS ✓ IDOS ✓ IDOS ✓ IDOS & USB TERPS ✓ IDOS & USB TERPS ✓ IDOS & USB TERPS ✓ PM700E 0.025 to 1400 bar
 Pressure Measurement
 Pressure Source* X X X X ✓ with PV62X base X
 Loop Measurement X X X X
 Loop Source X X X X
 Frequency Measurement and Source X X X X X X X
 Temperature Measurement External (optional RTD interface) X X X Internal – measures RTD & TCs X Internal & optional RTD interface External (optional RTD interface)
 Data Logging X ✓ (optional) X ✓ (optional) X X X X
 Compatible with 4Sight X X X X X X
 Pass/Fail Analysis X X X X X X X
 Hart, Fieldbus, Profibus Options X X X X ✓ (resistance only) ✓ (resistance only) HART only
 Hazardous Area (IS) Version X X X X X X X
 Datasheet
 Product Page → PRODUCT → PRODUCT → PRODUCT → PRODUCT → PRODUCT → PRODUCT → PRODUCT

The table on the right provides a breakdown of the entire Druck portable calibrator range.

Please refer to the product datasheets for more information.

* Note: Pressure source available through PV210/PV211/PV212 & PV411A for DPI705, DPI104, DPI802, and DPI880