5070 koffer

For monitoring, controlling, and diagnosing pressurized systems, the precise measurement of pressure, temperature, and flow rate is essential. The MultiSystem 5070 is the indispensable tool for fluid specialists and professional service technicians. Individually selectable favorites, easy screenshot creation, and high-performance lithium-ion battery technology with a fast-charging function ensure comfortable and efficient operation throughout the entire working day.


The MultiSystem 5070 features six analog measurement inputs, two switchable inputs (f/A), and one digital input and output. In addition, 32 special channels are available for calculations or CAN integration. The signal inputs support various measuring ranges such as 0/4…20 mA, 0/2…10 V, 1…5 V, 0.5…4.5 V, and ±10 V. For frequency and pulse measurements with direction detection, ranges from 0.25 Hz to 20 kHz are possible.


The internal memory holds up to 500 measurement series, with up to six million measured values storable per series. For communication and data transfer, the device offers a wide range of interfaces: USB Device, USB Host, RS232, and two CAN interfaces (CAN 1: J1939/CANopen, Hydrotechnik products; CAN 2: J1939/CANopen).


The system can be flexibly expanded with various channel extensions via MultiXtend. The configuration of the measurement set can be individually adapted to the application with pressure, temperature, and flow sensors, MultiXtend, or a particle monitor.




MultiSystem 5070 Sets


With the MultiSystem 5070 sets, you receive professional complete solutions for precise measurements in the fields of pressure, temperature, and flow. The sets are specially tailored to the requirements of service, maintenance, and mobile testing tasks. Each set includes the powerful MultiSystem 5070 measuring device as well as high-quality accessories that enable direct and flexible commissioning. Depending on the version, you receive the appropriate pressure sensors, temperature sensors, and/or flow sensors as well as extensive accessories for comfortable and efficient use in everyday operations. Thanks to the robust transport cases, all components are securely stored and ready for use at any time.


MultiSystem 5070 pp Set

5070pp

Measurement Range
HySense® PR 400 Pressure Sensor
Code
0 … 600 bar 18
0 … 400 bar 15
0 … 250 bar 17
0 … 60 bar 21

The MultiSystem 5070 pp Set is a practical all-in-one solution for professional pressure measurement and monitoring in industrial and service applications. The set consists of the robust MultiSystem 5070 measuring device, two high-quality HySense® PR 400 pressure sensors (selectable in the range from 0…60 bar up to 0…600 bar), two measuring cables (5 m each), two direct connectors, a power supply unit, USB cable, USB stick, and the comprehensive HYDROcom6 ADVANCED software. All components are safely and neatly housed in a sturdy plastic case. This ensures that users always have a complete measuring system at hand – ideal for mobile use and quick commissioning on site.



Scope of Delivery
1x MultiSystem 5070 1x USB cable 2x MINIMESS® direct connectors 1620 1x USB stick
2x HySense® PR 400 pressure sensors 1x power supply unit 2x measuring cables standard 5 m 1x HYDROcom6 ADVANCED software
1x plastic case

 


MultiSystem 5070 ppTQ Set

5070ppqt


Measuring Range
HySense® PR 400 Pressure Sensor
Code Measuring Range
HySense® QT 500 Flow Sensor
Code
0 … 600 bar 18 600 l/min 72
0 … 400 bar 15 300 l/min 71
0 … 250 bar 17
0 … 60 bar 21

The MultiSystem 5070 ppTQ Set is a comprehensive complete package for mobile measurement and analysis of pressure, temperature, and flow. It includes the MultiSystem 5070 device, two HySense® PR 400 pressure sensors (measuring range selectable between 0…60 bar and 0…600 bar), one HySense® TE 300 temperature sensor, and one HySense® QT 500 flow sensor (either for 300 l/min or 600 l/min). The set is complemented by four measuring cables, two MINIMESS® direct connectors, a power supply, USB cable, USB stick, the powerful HYDROcom6 ADVANCED software, and a robust plastic case.


This set thus offers a flexible solution for a wide range of measurement tasks in hydraulics, maintenance, and service – ideal for users who want to record multiple physical quantities precisely and conveniently with just one system.



Scope of Delivery
1x MultiSystem 5070 1x Power supply 2x MINIMESS® direct connector 1620 1x USB cable
2x HySense® PR 400 pressure sensor 4x Measuring cable standard 5 m 1x HySense® TE 300 temperature sensor 1x USB stick
1x HySense® QT 500 flow sensor 1x HYDROcom6 ADVANCED software 1x Plastic case

Technical Data and Specifications


Parameter Value Remark
Housing PC+ABS+20GF plastic
Weight 1,072 g
Protection class IP40
CE marking Complies with Directive 2014/30/EU (EMC);
Complies with Directive 2014/68/EU (Pressure Equipment Directive);
Complies with Directive 2011/65/EU (RoHS)
Internal power supply Lithium-ion, 7.2 V / 6.2 Ah
External power supply 24 VDC / 2A
Dimensions ~270 x 140 x 69 mm (L x W x H)
Interfaces USB, USB host, RS232 interface, 2 x CAN
Ambient temperature -10 °C – 50 °C
Relative humidity 0 – 80% (non-condensing)
Storage temperature -20 °C – 50 °C
Measurement display 5 digits / 5″ color TFT QVGA (320 x 240)
Trigger 4 channels for start/stop;
AND/OR links;
Time-based triggering
Sampling rate adjustable from 100 μs to 999 min
Number of signal inputs 8 6 x AD, 2 x switchable
Signal input measurement rate 0.1 ms
Digital low-pass filter 5 kHz, 50 Hz
Number of digital inputs 1 Electrically isolated
Digital input measurement rate 1 ms
Number of digital outputs 1 Max. load Ub/10mA
Digital output response time ≤ 1 ms
Number of CAN inputs 32 CAN, CANopen, SAE J1939
Storage medium SD card 4 GB microSD card
Number of measurement series 500
Measurement value memory max. 24 MB / measurement series
max. 6 million measured values
Average charging time < 2 h at 25 °C and 90% state of charge
Battery powered operation time 10 h 8 sensors with 12 mA load
Optimal storage conditions 20…60% 20°C, 15…65% r.h.
Recommended charging cycle when not in use 6 months
Backup battery CR2032
Measurement rate Analog inputs max. 10 kHz
Frequency inputs 0.25 Hz … 20 kHz
Measurement accuracy Analog ± 0.10% of full scale,
Digital ± 0.02% of measured value (20 ns)

 

5070 zeichnung

Electrical Characteristics


Parameter Min Typ. Max Unit Remarks
Input signal current 0 20 mA
Input impedance current 113Ω/35nF Channel 1-6
113Ω/100nF Channel 7-8
Error limit 20mA signal input ±0.1 % FS
Input signal voltage -10 10 V
Input impedance voltage 8.8kΩ/35nF Channel 1-6
8.8kΩ/100nF Channel 7-8
Error limit 10V signal input ±0.1 % FS
Input signal frequency 0.25 20000 Hz Direction detection 45° to 135° with 5V TTL
Input impedance f-signal 100kΩ/33nF
Error limit f-signal ±0.02 % MV
Signal digital input (high) 2 30 VDC
Temperature error ±0.005 %/°C Only for analog inputs
Power supply sensor 14.4 15.1 VDC Current limit 200 mA
Power supply CAN / MultiXtend 14.6 15 VDC 800 mA

Absolute Limits


Parameter Min Max Unit Condition
Supply voltage 11 26 VDC Current limit 2A
Storage temperature -20 50 °C
Operating temperature -10 50 °C
Charging temperature 10 40 °C
Relative humidity 0 80 % r.h. Not condensing

Mechanical Properties


Parameter Value
Casing PC+ABS+20GF plastic
IP protection class IP40
Dimensions 270 x 140 x 69 mm
Weight 1.072 kg

Software Compatibility


Microsoft Windows Windows 71
Windows 8.1
Windows 10
Hydrotechnik HYDROcenter
HYDROlink 6
HYDROcom 6

¹ Requires device driver available from the Hydrotechnik website.


Connections


The MultiSystem 5070 offers a wide range of connections and interfaces for versatile measurement and diagnostic tasks.


  • 8 measurement channels: six analog inputs, two switchable between analog or frequency pulse including direction detection

  • Digital input/output: for trigger- or counter-based signal processing

  • Two CAN interfaces: separate ports for J1939/CANopen, each with up to 32 special channels

  • USB Device & USB Host: connection to PC or USB storage, recognized as a removable device

  • RS‑232 interface: classic interface for data transmission and device control


This wide variety of interfaces makes the MultiSystem 5070 an extremely flexible and powerful tool for a wide range of measurement applications.


anschlüsse 5070

▲ Characteristics of Analog Inputs

pins1
Number 8 (K1 to K6)
Signal input switchable 0/4 … 20 mA;
0/2 … 10V; 0 … 10V; 0.5 … 4.5V; 1 … 5V
Resolution 13-bit analog/digital converter (12-bit + sign)
Measurement rate max. 10,000 measured values / sec.
Filter function Input filter 50 kHz (dynamic mode)
IIR filter switchable: 5 kHz (standard mode) / 50 Hz (attenuated mode)
Connector 6-pin device connector
Protection class IP40

Pin Assignment


Pin Function Ri Ci Limitation Protection
1 Signal I [mA] 113 Ω 35 nF 5VDC Transil diode
2 Ground
3 Uba 100 mA Current limitation
4 Signal U [V] 8.8 kΩ 35 nF ± 15VDC Transil diode
5 Shield
6 ISDS


*) Supply voltage with mains operation 15 V


 


▲ Characteristics of Frequency/Analog Inputs

pins1
Number 2 (K7, K8) frequency/counter inputs with selectable direction detection or analog inputs
Signal input (frequency mode) 5 – 30VDC
0.25 Hz – 20 kHz
Signal input (analog mode) switchable 0/4 … 20mA;
0/2 … 10V; 0 … 10V; 0.5 … 4.5V; 1 … 5V
Resolution (analog mode) 13-bit analog/digital converter (12-bit + sign)
Measurement rate (analog mode) max. 10,000 measured values / sec.
Filter function (frequency mode) adjustable period duration measurement for mean value calculation
Filter function (analog mode) input filter 50 kHz (dynamic mode)
IIR filter (analog mode) switchable: 5 kHz (standard mode) / 50 Hz (damped mode)
Connector 6-pin device connector
Protection class IP40

Pin Assignment Frequency Mode


Pin Function Ri Ci Limit Protection
1 Signal (f) 100 k 33 nF 15VDC VDR transil diode
2 Ground
3 Uba 100 mA PTC
4 Direction signal 100 k 33 nF 15VDC VDR transil diode
5 Shield
6 ISDS


*) Supply voltage with mains operation 15 V


 


Pin Assignment Analog Mode


Pin Function Ri Ci Limit Protection
1 Signal I [mA] 110 Ω 32 nF 5VDC Transil diode
2 Ground
3 Uba) 100mA Current limitation
4 Signal U [V] 22 kΩ 32 nF ± 15VDC Transil diode
5 Shield
6 ISDS

a) Supply voltage with mains operation 15 V


 


▲ Characteristics of Digital Signal Input


pins2
Note

Potential damage to the device!
This input must not be connected directly to inductive loads (e.g. a solenoid valve coil). Otherwise, the device may be damaged.


Pins of the digital input/output.
The digital signal input is galvanically isolated.


Pin Assignment


Pin Function Limitation Protection
3 Signala) 30VDC VDR transil diode
4 Ground

a) 1 mA constant current


 


▲ Characteristics of Digital Signal Output


pins2

Sockets of the digital input/output.


Pin Assignment


Pin Function Limitation Protection
1 Ground
2 Signal Ub/10mA VDR Transil diode

 


▲ Characteristics Combo Socket CAN / RS 232


pins3

8-pin M12x1


Pin Assignment


Pin Function
1 Ground
2 Power supply for MultiXtend or CAN sensorsa)
3 DTR
4 CAN_H
5 TXD
6 RTS from PC (input)
7 CAN_L
8 RXD

a) ~14.6 to 15V, max. 800mA


 


▲ Characteristics Socket CAN 2


pins4

5-pin M12x1


Pin Assignment


Pin Function
1 Shield/Housing
2 Power supply for measuring devicea)
3 Ground
4 CAN_H
5 CAN_L

a) The measuring device automatically switches on the power supply via the CAN 2 socket. The device is then used for data recording only.


 


▲ Characteristics of the USB Interface


USB Type A: Host interface
USB Type B: Device interface