"Sterilization in Place" or "Steam in Place" (SIP) is an indispensable procedure in pharmaceutical production. It involves the sterilization of the respective process equipment directly in the system using condensing steam.
Sterilization after Cleaning in Place
After the process-specific cleaning procedures ("Cleaning in Place" or CIP), pipelines, devices, and other components of pharmaceutical manufacturing must be regularly and reliably sterilized. By killing any microorganisms such as germs, bacteria, and viruses, the desired product quality and thus patient safety are ensured.
Sterilization without Dismantling
In SIP processes, the sterilization of the process equipment takes place directly in the closed system using steam, without prior dismantling of the individual components. This minimizes the risk of recontamination. At the same time, manufacturers must design their production systems to be SIP-compliant, which means: free of dead spaces, with smooth surfaces, gap-free constructions, and without the risk of air pockets. The materials used must withstand high temperatures. A guideline for this task is the internationally recognized standard ASME BPE ("Bioprocessing Equipment"). WIKA measuring instruments for pharmaceutical applications comply with these requirements.
Hot Steam and Atmospheric Pressure
SIP is based on steam generated from pure water by a generator. The steam temperatures range between 121 °C and 134 °C under saturated steam conditions with an overpressure between 1 and 2 bar (15 and 30 psi). The sterilization time at the coldest point is at least 20 minutes. However, pressure and temperature in SIP can vary depending on the device design, product sensitivity, and regional regulations. The requirements are set by the relevant regulatory bodies and institutions, such as the "Food and Drug Administration" (FDA) in the USA and the "European Medicines Agency" (EMA) in Europe.
Automation and Validation of SIP Processes
Most SIP processes are automated to ensure consistency and reliability. Appropriate instrumentation monitors the critical parameters of temperature, pressure, and sterilization duration. The SIP process also requires comprehensive documentation of the procedures. Validation of these processes is essential to prove that all sterilization requirements are met and that the underlying regulations are followed. As necessary as the validation of the procedures is the regular inspection and maintenance of the SIP systems. This also includes the calibration of all measuring instruments.
Comprehensive Product Portfolio for SIP Monitoring Tasks
The sterilization process places high demands on the instrumentation for its monitoring and control. WIKA offers a wide range of measuring instruments for this purpose. This includes both the monitoring of steam generation and the equipment suitable for the SIP process.
- Double-diaphragm system prevents contamination of process and environment
- Hygienic process connections in different designs
- Signal transmission and configuration with only one cable per measuring location
- Minimal installation costs, even with retrofitting
![]() |
![]() |
- Multi-functional display
- Simple menu navigation
- Conductive plastic case
- Large LC display, rotatable
- Approvals for hazardous areas

![]() |
![]() |
- Dead space free
- Hygienic design
- Materials and surface finish qualities in accordance with pharmaceutical industry directives and standards
- 3-A compliant
![]() |
![]() |
- Quick cleaning, without residue
- Suitable for SIP and CIP
- EHEDG certified and 3-A compliant
- Certified hygienic design
![]() |
![]() |
- Quick cleaning, without residue
- Clamp connection easy to open for cleaning and seal replacement
- Suitable for SIP and CIP
![]() |
![]() |
- Easily readable, robust digital display
- Intuitive and fast setup
- Easy and flexible mounting configurations
- Flexibly configurable and scalable output signals
![]() |
![]() |
- For cleaning easy to open
- Quick cleaning of measuring point, without residue
- Suitable for SIP and CIP
- 3-A certified
- Flush, welded diaphragm
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
- Sensor can be calibrated without having to open the process
- Simple and fast electrical connection via M12 x 1 plug connector
- With direct sensor output (Pt100/Pt1000 in 3 or 4-wire version) or integrated transmitter with 4 ... 20 mA output signal, individually parameterisable with free-of-charge WIKAsoft-TT PC configuration software
- Wetted parts from stainless steel 1.4435
- Self-draining and dead-space minimised, materials and surface finish qualities in accordance with standards of hygienic design
![]() |
![]() |
![]() |
- TÜV zertifizierte SIL-Version für Schutzeinrichtungen entwickelt nach IEC 61508 (Option)
- Einsatz in Sicherheitsanwendungen bis SIL 2 (einzelnes Gerät) und SIL 3 (redundante Verschaltung)
- Konfigurierbar mit nahezu jedem offenen Soft- und Hardwaretool
- Universell für den Anschluss von 1 oder 2 Sensoren - Widerstandsthermometer, Widerstandssensor - Thermoelement, mV-Sensor - Potentiometer
- Signalisierung gemäß NAMUR NE43, Sensorbruchüberwachung gemäß NE89, EMV gemäß NE21


![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
- Scale ranges from -70 ... +600 °C
- For extreme ambient temperatures
- Maintenance-friendly bayonet case
- All stainless steel construction
- Individual stem length from 63 ... 1,000 mm
![]() |
![]() |
![]() |
- Scale ranges from -200 ... +700 °C [-328 ... 1.292 °F]
- Fast response behaviour
- Case and stem from stainless steel
- Various connection and case mounting designs
![]() |
![]() |
- Robust, hermetically sealed case
- Accuracy: ±1 % of full scale value ASME B40.200 (grade A)
- External reset for reference temperature adjustment
- Dished dial (anti-parallax) for ease of reading
- Adjustable stem and dial version enables optimal process connection

![]() |
![]() |
- Case and stem made of stainless steel
- Design per DIN EN 13190
- Different designs of connection and mounting
- With capillary
- With various fixed connections
![]() |
![]() |
![]() |
![]() |
- Variable welding diameters
- International standard
- Possible thermowell forms: - Design TW25-A: tapered - Design TW25-B: straight - Design TW25-C: stepped - "Quill Tip" version (with open tip)
![]() |
![]() |
- Materials and surface finish quality in accordance with the standards of hygienic design
- Fully welded
- Can be combined with models TR21-A and TR22-A electrical resistance thermometers, measuring insert exchangeable
- Can be combined with mechanical thermometers, resistance thermometers and DiwiTherm®
![]() |
![]() |
- Process- and system-specific solutions possible
- Operating limits: - Operating temperature: T = -80 ... +200 °C - Operating pressure: P = Vacuum up to 80 bar - Limit density: ρ ≥400 kg/m3
- Wide variety of different electrical connections, process connections and materials
- Optionally with programmable and configurable head-mounted transmitter for 4 ... 20 mA field signals, HART®, PROFIBUS® PA and FOUNDATION™ Fieldbus
- Explosion-protected versions (option)



![]() |
![]() |
![]() |
![]() |
![]() |
- Fully welded and dead space free
- Operating limits: - Operating temperature: T = -40 ... +250 °C - Operating pressure: P = Vacuum to 10 bar
- Insensitive to foaming, ideal for interface measurement
- High-precision level measurement: Accuracy < 0.5 mm
- Wide variety of hygienic process connections


![]() |
![]() |
![]() |
- Large range of application due to the simple, proven functional principle
- For harsh operating conditions, long service life
- Operating limits: - Operating temperature: T = -50 ... +350 °C - Operating pressure: P = Vacuum up to 40 bar - Limit density: ρ ≥ 300 kg/m3
- Wide variety of different electrical connections, process connections and materials
- Explosion-protected versions

![]() |
![]() |
![]() |
![]() |
![]() |
- Excellent load-cycle stability and shock resistance
- All stainless steel construction
- German Lloyd approva
- Scale ranges up to 0 … 1,600 bar

![]() |
![]() |
![]() |
![]() |
![]() |
- Safety version with solid baffle wall designed in compliance with the requirements and test conditions of EN 837-1
- Excellent load-cycle stability and shock resistance
- Completely from stainless steel
- Scale ranges from 0 … 0.6 to 0 … 1,600 bar

![]() |
![]() |
![]() |
![]() |
![]() |
- Sensor ranges from -196 ... +500 °C [-320 ... +932 °F]
- Compact design
- Universal application
- Direct installation into the process
- Explosion-protected versions are available for many approval types (see data sheet page 2)

![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
- For the connection of Pt100 and Pt1000 sensors in a 2-, 3- or 4-wire connection
- For the connection of reed chains in a potentiometer circuit
- Parameterisation with the WIKAsoft-TT configuration software and electrical connection via quick connector magWIK
- Connection terminals also accessible from the outside
- Accuracy < 0.2 K (< 0,36 °F) / 0.1 %

![]() |
![]() |
- Sensor ranges from -196 ... +600 °C (-320 ... +1.112 °F)
- For mounting in all standard thermowell designs
- Spring-loaded measuring insert (replaceable)
- Pt100 or Pt1000 sensors
- Explosion-protected versions

![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
- Sensor ranges from -196 ... +600 °C [-320 ... +1,112 °F]
- With integrated perforated protection tube model TW35
- Explosion-protected versions are available for many approval types (see data sheet page 2)
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
- Easily-readable, robust display
- Intuitive and fast setup
- Easy and flexible mounting configurations
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
- Dead-space free hygienic design with thick-walled sensor tube from stainless steel
- In-line pressure measurement with sensor tube without system fill fluid
- Continuous sensor monitoring of the double-tube system prevents contamination of process and environment
- Suitable for SIP and CIP
- EHEDG-certified and 3-A-compliant
![]() |
![]() |
- For direct, quickly removable installation in pipelines
- Self-draining in all mounting positions
- Quick cleaning, without residue
- Suitable for SIP and CIP
- Dead-space free installation in pipes
![]() |
![]() |
- Dead-space free, direct installation in pipes
- Easy to open, self-draining in all mounting positions
- Quick cleaning, without residue
- Suitable for COP, SIP and CIP
- Autoclavable version
![]() |
![]() |