WIKA Model TR36 Resistance thermometer – Threaded, compact version


  • Sensor range -50 … +250 °C [-58 … +482 °F]
  • Compact design
  • Electrical connection via angular connector DIN EN 175301-803 form A
  • With direct sensor output (Pt100 in 2-, 3- or 4-wire connection) or integrated transmitter
  • Integrated transmitter with 4 … 20 mA output signal, individually parameterisable with free-of-charge WIKAsoft-TT PC configuration software

Datasheet
User Manual

Applications

  • Machine building, plant and vessel construction
  • Propulsion technology, hydraulics

 

Description

Resistance thermometers of these series are used as universal thermometers for the measurement of liquid and gaseous media in the range -50 … +250 °C [-58 … +482 °F].

They can be used for pressures up to 140 bar [2,030 psi] with 3 mm [0.12 in] protection tube diameters, up to 270 bar [3,916 psi] with 6 mm [0.24 in] protection tube diameters, and up to 400 bar [5,801 psi] with 8 mm [0.31 in] protection tube diameters, depending on the instrument version. All electrical components are protected against splash water and designed to withstand vibration (8 g, depending on instrument version).

The TR36 resistance thermometer consists of a probe tube, which can be fixed into the process using a permanently welded threaded connection or a compression fitting. A version without process connection is also available.

The instrument version with integrated transmitter can be configured individually via the WIKAsoft-TT PC configuration software. Measuring range, dampening, error signalling per NAMUR NE 043 and tag no. can be adjusted.









Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    WIKA Model TR36 Resistance thermometer – Threaded, compact version

    • Sensor range -50 … +250 °C [-58 … +482 °F]
    • Compact design
    • Electrical connection via angular connector DIN EN 175301-803 form A
    • With direct sensor output (Pt100 in 2-, 3- or 4-wire connection) or integrated transmitter
    • Integrated transmitter with 4 … 20 mA output signal, individually parameterisable with free-of-charge WIKAsoft-TT PC configuration software

    Datasheet
    User Manual

    Applications

    • Machine building, plant and vessel construction
    • Propulsion technology, hydraulics

     

    Description

    Resistance thermometers of these series are used as universal thermometers for the measurement of liquid and gaseous media in the range -50 … +250 °C [-58 … +482 °F].

    They can be used for pressures up to 140 bar [2,030 psi] with 3 mm [0.12 in] protection tube diameters, up to 270 bar [3,916 psi] with 6 mm [0.24 in] protection tube diameters, and up to 400 bar [5,801 psi] with 8 mm [0.31 in] protection tube diameters, depending on the instrument version. All electrical components are protected against splash water and designed to withstand vibration (8 g, depending on instrument version).

    The TR36 resistance thermometer consists of a probe tube, which can be fixed into the process using a permanently welded threaded connection or a compression fitting. A version without process connection is also available.

    The instrument version with integrated transmitter can be configured individually via the WIKAsoft-TT PC configuration software. Measuring range, dampening, error signalling per NAMUR NE 043 and tag no. can be adjusted.









    Technical advice: 03303 / 50 40 66