Weighing technology
Load cells serve as a specialized form of force sensors designed specifically for use in various weighing systems, including platform scales, filling scales, belt scales, packaging scales, dynamic testing equipment, as well as electronic price labeling and industrial scales. These sensors seamlessly integrate into their respective systems, providing extremely precise measurements with an accuracy ranging between 0.01% and 0.05% of the rated capacity.
To meet diverse requirements, we offer a wide range of load cell designs, complemented by suitable mounting kits and complete weighing modules. A prominent application example is the batch process, in which different quantities of multiple components are precisely dosed and then mixed. The highly precise and stable load cells ensure efficient and accurate dosing. An outstanding feature of our load cells is their resistance to lateral forces, making them particularly versatile in application.
- Measuring ranges 10 kN, 20 kN
- Relative linearity error 0.2 % Fnom
- Low overall weight of approx. 6 kg
- Maximum/Minimum value memory
- Electrode diameter 14 … 20 mm
Datasheet |
- Measuring ranges 0 ... 6 t up to 0 … 25 t (others possible)
- Relative linearity error < 0.5 % Fnom
- Type tested in accordance with OIML R60 (certificate R60/2000-A-NL-18.05) with D175
- Optimal for retrofitting with simple integration into the crane network through CANopen® and CAN SAE J1939 technologies
- High overload capacity, long service life of the measuring spring, large shock and vibration resistance
Datasheet |
- Measuring ranges 40 ... 3,500 kg
- Simple calibration of friction clutches without weights
- Single sensor concept for entire load range
- Maximum- / minimum value memory
- Relative linearity error 0.5 % Fnom
Datasheet |
- Measuring ranges 0 ... 1 t to 0 ... 30 t
- Relative linearity error up to ≤ ±1.0 % Fnom
- Wire rope diameter 8 ... 44 mm, suitable for retrofitting
- Material: Stainless steel, IP67
- Optional: Redundant output signal, ATEX version
Datasheet |
User Manual |
- Measuring ranges strains from 0 ... 200 με up to max. 0 ... 1,000 με
- Good long-term stability, high shock and vibration resistance, good reproducibility
- As retrofitting, easy to install
- For use in extreme outdoor applications (IP67)
- Relative linearity error < 2 % Fnom
Datasheet |
User Manual |
- Strain of 0 … 200 με to max. 0 … 1,000 με
- Can be retrofitted, easy installation with M6-screws
- Total error < 1 % Fnom
- Electrical connection as cable, with plug-in radio module, display or junction box.
Datasheet |
- Measuring ranges 0 ... 6 t up to 0 … 25 t (others possible)
- Relative linearity error 2 % Fnom
- Optimal for retrofitting with simple integration into the crane network through CANopen® and CAN SAE J1939 technologies
- High overload capacity, long service life of the measuring spring, large shock and vibration resistance
- Exceptionally space-saving, ideal for retrofitting onto the spreader
Datasheet |
- Measuring ranges 0 … 1 t up to 0 ...4 0 t
- Integrated amplifier, output 4 … 20 mA, 2-wire
- Simple mounting (without opening rope), suitable for retrofits
- Material alloyed steel
- Protection class IP66
Datasheet |
User Manual |
- 5-digit digital display, easy to read up to 50 m
- High accuracy: 0.02 % of reading +3 μV
- Extensive functions easy to set on the instrument or via PC
- Plug-in expansion cards, analogue output, 2 or 4 limit values, serial interface
- Ingress protection IP65
Datasheet |
- 6-digit liquid crystal display (LCD) with backlighting
- Extensive functions easy to set on the instrument or via PC
- International approval for applications requiring verified measurements OIML, NTEP
- AC, DC (DC 7 ... 24 V) operating on (rechargeable) battery power (DC 4.8 ... 24 V) – ideal for a number of mobile applications
- High ingress protection, IP65
Datasheet |
- 5-digit digital display, easy to read up to 50 m
- High accuracy: 0.03 % of reading +2 μA or +2 mV
- Extensive functions easy to set on the instrument or via PC
- Plug-in expansion cards, analogue output, 2 or 4 limit values, serial interface
- Ingress protection IP65
Datasheet |
- Certified safety electronics, certified in accordance with DIN EN ISO 13849-1, PLe
- Certified system solution incl. force measurement, certified in accordance with DIN EN 13849-1 Cat. 3, PLd
- 16 x safe inputs (8 x 4 ... 20 mA analogue inputs, 8 x digital inputs), 2 x safe relay outputs and 6 x safe solid-state outputs (positive switching)
- Additional module with ProfiBus®, ProfiNet®, EtherCat® and CANopen®
- Complex functionality, easy to configure via PC
Datasheet |
User Manual |
- Reliable electrical connection
- Pre-assembled
- Shielded for high electromagnetic immunity
- Ready for immediate use
- Optional: with knurled nut made from stainless steel
Datasheet |
- 24 input/output channels (of which 8 are analogue inputs, 2 CAN bus interfaces)
- Complex functionality, easy to configure via PC
- Including application and AMP plug connection
- High EMC and shock/vibration resistance
- Robust metal case, ingress protection IP67
Datenblatt |
- Good linearity
- Voltage and current output
- Compact design
- Optional, continuous adjustment of zero point and full scale
- Optional with adapter board for DIN-rail mounting
Datasheet |
- Analogue input 0/4 ... 20 mA 2- and 3-wire
- Galvanic isolation, line break (LB) and short-circuit (SC) monitoring
- Easy setting of extensive functions on the instrument or via PC software
- Two potential-free relay contacts (change-over) with status LED and a freely-programmable analogue output (0 ... 20 mA)
Datasheet |
User Manual |
- High accuracy
- Input signal: strain gauge resistance thermometry bridge; output signal 0/4 ... 20 mA or DC 0 ... 10 V
- Cable length between amplifier and read-out unit: up to 100 m are possible
- Compact design
- Ingress protection IP67
Datasheet |
- High accuracy
- Input signal: strain gauge measuring bridge; Output signal: 0/4 … 20 mA or DC 0 … 10 V
- Cable length between amplifier and read-out unit: up to 100 m are possible
- Compact design
- Ingress protection IP67
Datasheet |
User Manual |
- Limit switch for mV/V signals
- 3 relay outputs
- Adjustable control for switching thresholds
- Simple operation and setting
- Case for DIN-rail mounting
Datasheet |
- Dual mV/V display
- 2x digital input and 4x digital output
- Integrated multiple signal outputs available
- Serial interface, RS-232 or RS-485
- Ingress protection IP65
Datasheet |
- Measuring ranges 0 ... 550 N to 0 ... 310 kN [0 ... 123,645 lbf to 0 ... 69,691 lbf]
- Relative linearity error: ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ≤ ±0.5 % Fnom with digital pressure gauge or pressure sensor
- Piston stroke ≤ 0.5 mm [≤ 0.02 in]
- Operates without supply voltage
- 5-year leak-tightness warranty
Datasheet |
- Measuring ranges 0 ... 3 kN to 0 ... 450 kN
- Relative linearity error 2 % Fnom
- Material: Stainless steel
- Ingress protection IP65
Datasheet |
- Measuring ranges 0 ... 15 kN to 0 ... 1,500 kN
- Compact design, easy installation
- Ingress protection IP65
- Relative linearity error 1 % Fnom
Datasheet |
- Measuring ranges 0 ... 2 kN up to 0 ... 100 kN
- For compression force measurements
- Flat dimensions
- Stainless steel measuring body
- Protection class IP65
Datasheet |
- Measuring ranges 0 ... 800 kN to 0 ... 6,000 kN [179,847 lbf to 1,348,854 lbf]
- Relative linearity error ±1.0 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor
- Piston stroke ≤ 0.5 mm [≤ 0.02 in]
- Operation without supply voltage with analogue displays
- Case and piston made of galvanised steel
Datasheet |
User Manual |
- Measuring ranges 0 ... 400 kN to 0 ... 3,200 kN [0 ... 89,924 lbf to 0 ... 719,389 lbf]
- Relative linearity error ±1.0 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor
- Piston stroke ≤ 0.5 mm [≤ 0.02 in]
- Operates without supply voltage
- Case and piston made of galvanised steel
Datasheet |
User Manual |
- Measuring ranges 0 ... 25 kN to 0 ... 1,500 kN [5,620 lbf to 337,213 lbf]
- Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor
- Piston stroke ≤ 0.8 mm [≤ 0.03 in]
- Operates without supply voltage
- 5-year leak-tightness warranty
Datasheet |
- Measuring ranges 0 ... 150 kN to 0 ... 1,500 kN [0 ... 33,721 lbf to 0 ... 337,213 lbf]
- Relative linearity error ±1.0 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor
- Piston stroke ≤ 0.5 mm [≤ 0.02 in]
- Operates without supply voltage
- Case and piston made of galvanised steel
Datasheet |
User Manual |
- Measuring ranges 0 ... 80 kN to 0 ... 700 kN [0 ... 17,985 lbf to 0 ... 157,366 lbf]
- Relative linearity error ±1.0 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor
- Piston stroke ≤ 0.5 mm [≤ 0.02 in]
- Operates without supply voltage
- Case and piston made of galvanised steel
Datasheet |
User Manual |
- Measuring ranges 0 ... 320 N to 0 ... 120 kN [0 ... 72 lbf bis 0 ... 26,977 lbf]
- Relative linearity error ±1.0 ... ±1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor
- Piston stroke ≤ 0.5 mm [≤ 0.02 in]
- Operates without supply voltage
- 5-year leak-tightness warranty
Datasheet |
- Fine-grained structural steel with high-quality surface protection or in corrosion-resistant stainless steel version
- High long-term stability, high shock and vibration resistance
- For dynamic and static measurements
- Excellent reproducibility
Datasheet |
User Manual |
- Measuring ranges 0 ... 5 kN up to 0 ... 10,000 kN
- Corrosion-resistant stainless steel design
- Existing non-measuring bolts are simply replaced by the measuring axes
- For overload protection in cranes and hoists
- Good reproducibility, simple installation
Datasheet |
- Measuring ranges from 0 ... 10 kN [from 0 ... 2,248 lbf]
- Stainless steel version (corrosion-resistant)
- Integrated amplifier
- High long-term stability, high shock and vibration resistance
- Good reproducibility, simple installation
Datasheet |
User Manual |
- Measuring ranges 0 ... 5 kN to 0 ... 200 kN [0 ... 1,124 lbf to 0... 44,962 lbf]
- Stainless steel version (corrosion-resistant)
- Integrated amplifier
- High long-term stability, high shock and vibration resistance
- Good reproducibility, simple installation
Datasheet |
User Manual |
- Measuring ranges 0 ... 2 kg to 0 ... 30 kg [0 ... 4 lbs to 0 ... 66 lbs]
- Load cell made from aluminium
- High accuracy, react quickly, low settling time
- Insensitive to lateral and corner load
- Simple design, easy installation
Datasheet |
- Measuring ranges 0 ... 3 kg to 0 ... 40 kg [0 ... 7 lbs to 0 ... 88 lbs]
- Load cell made from aluminium
- High accuracy, react quickly, low settling time
- Insensitive to lateral and corner load
- Simple design, easy installation
Datasheet |
- Measuring ranges 0 ... 8 kg to 0 ... 300 kg [0 ... 18 lbs to 0 ... 661 lbs]
- Load cell made from aluminium
- High accuracy, react quickly, low settling time
- Insensitive to lateral and corner load
- Simple design, easy installation
Datasheet |
- Measuring ranges 0 ... 50 kg to 0 ... 635 kg [0 ... 110 lbs and 0 ... 1,400 lbs]
- Load cell made from aluminium
- High accuracy, react quickly, low settling time
- Insensitive to lateral and corner load
- Simple design, easy installation
Datasheet |
- Measuring ranges 0 ... 1 kg to 0 ... 200 kg [0 ... 2.2 lbs to 0 ... 441 lbs]
- Load cell made from aluminium
- High accuracy (6-wire connection), react quickly, low settling time
- Insensitive to lateral and corner load
- Simple design, easy installation
Datasheet |
- Measuring ranges 0 … 20 kg up to 0 ... 500 kg
- Made of aluminum
- High accuracy
- Insensitive to side and corner loads
- Simple structure, easy to install
Datasheet |
User Manual |
- High overload protection up to 400 %
- 0.1 % FS Accuracy
- Meets the highest EMC requirements
- Measuring ranges 0 ... 27.22 kg to 0 ... 136.08 kg [0 ... 60 lbs to 0 ... 300 lbs]
- High ingress protection, IP65, for outdoor use and processes with high condensation
Datasheet |
User Manual |
- Measurement ranges 0 ... 3 kg up to 0 ... 250 kg
- Made of aluminum alloy
- High accuracy
- High side load tolerance
- Simple structure, easy to install
Datasheet |
User Manual |
- Measuring ranges 0 … 0.3 kg up to 0 ... 10 kg
- Made of aluminum alloy
- High accuracy
- Insensitive to side and corner loads
- Simple structure, easy to install
Datasheet |
User Manual |
- Measuring ranges 0 … 5 kg up to 0 ... 500 kg
- Completely welded bellows
- Protection class IP68
Datasheet |
- Measuring ranges 0 … 500 kg up to 0 ... 10.000 kg
- Steel/stainless steel
- High long-term stability
- High side load tolerance
Datasheet |
- Measuring ranges 0 ... 2 kN up to 0 ... 100 kN
- Corrosion-resistant stainless steel design
- Integrated amplifier
- High long-term stability, high shock and vibration resistance
- Good reproducibility, simple installation
Datasheet |
User Manual |
- Measuring ranges 0 ... 20 kg to 0 ... 500 kg
- 3,000 intervals per OIML R60 Class C
- Stainless steel, hermetically sealed and welded bellows
- Ingress protection: IP68 and IP69K
Datasheet |
User Manual |
- Measuring ranges 0 ... 500 to 0 ... 2,000 kg
- 3,000 intervals per OIML R60 Class C
- Stainless steel, hermetically sealed and welded, Ingress protection: IP68 and IP69K
- High long-term stability
- High side load tolerance
Datasheet |
User Manual |
- Measuring ranges 0 ... 10 kN to 0 ... 45 kN [0 ... 2,248 lbf to 0 ... 10,116 lbf]
- Corrosion-resistant stainless steel design
- Integrated amplifier
- High long-term stability, high shock and vibration resistance
- Good reproducibility, simple installation
Datasheet |
User Manual |
WIKA Model F2220 Miniature tension/compression force transducer For small measuring ranges from 10 N
- Measuring ranges 0 ... 10 N up to 0 ... 5,000 N
- Standard calibration: tension / compression (positive in tension)
- Ease of assembly
- Small geometries
- Stainless steel version
Datasheet |
User Manual |
- Measuring ranges 0 ... 5 kN up to 0 ... 500 kN
- Ultra compact design
- Simple installation, low installation height
- Protection IP66
Datasheet |
User Manual |
- Measuring ranges 0 ... 50 N up to 0 ... 1,000 N
- Ultra compact design
- Corrosion-resistant stainless steel design
- Protection IP65
Datasheet |
User Manual |
- Measuring ranges 0 … 5 N up to 0 ... 2,000 N
- Overload protection
- Ultracompact version
- Material: Stainless steel
Datasheet |
User Manual |
- Measuring ranges 0 ... 0,5 kN up to 0 ... 50 kN
- Corrosion-resistant stainless steel or steel design
- Protection IP65 (< 5 kN), IP67 (≥ 5 kN)
Datasheet |
User Manual |
- Measuring ranges 0 ... 1 kN to 0 ... 200 kN [0 ... 225 lbf to 0 ... 44,962 lbf]
- Corrosion-resistant stainless steel design
- Integrated amplifier
- High long-term stability, high shock and vibration resistance
- Good reproducibility, simple installation
Datasheet |
User Manual |
- Measuring ranges 0 ... 1 kN to 0 ... 500 kN [0 ... 224.8 lbf to 0 ... 112,404 lbf]
- Stainless steel version (corrosion-resistant)
- Integrated amplifier
- High long-term stability, high shock and vibration resistance
- Good reproducibility, easy installation
Datasheet |
User Manual |
- Measuring ranges 0 ... 0.22 kN up to 0 ... 890 kN (0 ... 50 lbs up to 0 ... 200,000 lbs)
- Robust design
- Material stainless steel
- Protection class IP66
- Relative linearity error 0.1 % Fnom
Datasheet |
- Measuring ranges 0 ... 10 kN up to 0 ... 3,300 kN
- Robust design
- Material stainless steel
- Protection class IP66
- Relative linearity error 0.15 % Fnom
Datasheet |
User Manual |
- Measuring ranges 0 ... 22 N up to 0 ... 2.200 kN (0 ... 5 Ibs up to 0 ... 500 klbs)
- Simple installation, low installation height
- High long-term stability, dynamic fatigue strength for load alternations
- Protection class IP66
- Relative linearity error 0.1 % Fnom
Datasheet |
WIKA Model F2221 Miniature tension/compression force transducer For small measuring ranges from 10 N
- Measuring ranges 0 … 10 N up to 0 ... 50 kN
- Standard calibration: tension / compression (positive in tension)
- Ease of assembly
- Small geometries
- Stainless steel version
Datasheet |
User Manual |
WIKA Model F1861 Compression force transducer With bilateral spherical force introduction up to 50 t
- Measuring ranges 0 ... 10 t to 0 ... 50 t
- Relative linearity error 0.03 % Fnom
- Material: Stainless steel version, IP67
- Self-centring rocker pins with dual spherical force introduction
- Adapter plates available
Datasheet |
- Measuring ranges 0 ... 7.5 t to 0 ... 300 t
- For compression forces
- Ingress protection IP68, hermetically sealed
- Relative linearity error from 0.0166 % Fnom
Datasheet |
- Measuring range from 1 t
- Relative linearity error ±0.15 % Fnom
- Redundant output signal for safety applications
- Low installation height, easy to install
- Ingress protection: IP67
Datasheet |
User Manual |
- Measuring ranges 0 ... 280 kN to 0 ... 2,060 kN
- Insensitive to lateral forces
- Stainless steel version (corrosion-resistant)
- Integrated amplifier
- High long-term stability, high shock and vibration resistance, good reproducibility
Datasheet |
- Measuring ranges 0 ... 100 N to 0 ... 36 kN
- Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
- Piston stroke ≤ 0.5 mm
- Operates without supply voltage
- 5-year leak-tightness warranty2)
Datasheet |
User Manual |
- Measuring ranges 0 ... 200 N to 0 ... 100 kN
- Relative linearity error 0.5 % Fnom
- Stainless steel version
- Low installation height, easy to install
- Ingress protection IP66
Datasheet |
User Manual |
- Measuring ranges 0 ... 50 N to 0 ... 5 kN
- Relative linearity error 0.5 % Fnom
- Material: Stainless steel
- Low installation height, easy to install
- Ingress protection IP65
Datasheet |
User Manual |
- Measuring ranges 0 ... 50 N to 0 ... 1,000 N
- Relative linearity error 1 % Fnom
- Stainless steel or aluminium version
- Low installation height, easy to install
- Ingress protection IP64
Datenblatt |
Bedienungsanleitung |
- Measuring ranges 0 ... 2.5 kN to 0... 300 kN
- Relative linearity error 0.1 % Fnom
- Stainless steel version, completely welded
- Low installation height, easy to install
- Ingress protection IP67
Datasheet |
User Manual |
- Measuring ranges 0 ... 0.02 kN to 0 ... 2,200 kN (0 ... 5 lbs to 0 ... 500,000 lbs)
- Robust version
- Material: Stainless steel
- Ingress protection as of IP66
- Relative linearity error as of 0.1 % Fnom
Datasheet |
- Measuring ranges 0 ... 25 N to 0 ... 225 kN [0 ... 5 lbs to 0 ... 50,000 lbs]
- Relative linearity error 0.25 % Fnom
- Simple force introduction
- Compact design, low installation height
- Ingress protection IP67
Datasheet |
- Measuring ranges 0 … 1 kN up to 0 ... 500 kN
- Simple force introduction
- Compact small dimensions
- Protection class IP65
- Relative linearity error 1 % Fnom
Datasheet |
- Measuring ranges 0 ... 10 N up to 0 ... 5,000 N
- Ease of force input, easy installation
- Compact and small dimensions, low installation height
- Protection class IP65
- Relative linearity error 1 % Fnom
Datasheet |
- Measuring ranges 0 ... 1 kN up to 0 ... 1,000 kN
- For compression force measurements
- Simple force introduction, easy installation
- Protection class IP67
- Relative linearity error 0.3 % Fnom (0.1 % Fnom optional)
Datasheet |
- Measuring ranges 0 ... 6 kN to 0 ... 850 kN
- Relative linearity error ±1.0 ... 1.6 % with analogue pressure gauge, ±0.5 % with digital pressure gauge or pressure sensor1)
- Piston stroke ≤ 0.5 mm
- Operates without supply voltage
- 5-year leak-tightness warranty2)
Datasheet |
- Measuring ranges 0 ... 1.2 kN to 0 ... 500 kN
- Flattened case for stable measurement
- Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
- Operates without supply voltage
- 5-year leak-tightness warranty2)
Datasheet |
User Manual |
- Measuring ranges 0 ... 2 kN to 0 ... 480 kN
- Relative linearity error ±1.0 ... 1.6 % with analogue pressure gauge, ±0.5 % with digital pressure gauge or pressure sensor1)
- Piston stroke ≤ 0.5 mm
- Operates without supply voltage
- 5-year leak-tightness warranty2)
Datasheet |
User Manual |
- Measuring ranges 0 ... 4 kN to 0 ... 400 kN
- Relative linearity error ±1.0 ... 1.6 % with analogue pressure gauge, ±0.5 % with digital pressure gauge or pressure sensor1)
- Piston stroke ≤ 0.8 mm
- Operates without supply voltage
- 5-year leak-tightness warranty2)
Datasheet |
User Manual |
- Measuring ranges 0 ... 6 kN to 0 ... 1,000 kN
- Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
- Piston stroke ≤ 0.5 mm, force introduction as total clamping force
- Operates without supply voltage
- 5-year leak-tightness warranty2)
Datasheet |
- Measuring ranges 0 ... 5 t to 0 ... 30 t
- 1,000 intervals per OIML R60 Class C
- Measuring element from stainless steel
- Hermetically sealed and welded, ingress protection IP68
Datasheet |
User Manual |
- Measuring ranges 0 ... 320 N to 0 ... 120 kN
- Flattened case for stable measurement
- Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
- Operates without supply voltage
- 5-year leak-tightness warranty2)
Datasheet |
User Manual |
- Measuring ranges 0 ... 320 N to 0 ... 120 kN
- Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
- Piston stroke ≤ 0.5 mm
- Operates without supply voltage
- 5-year leak-tightness warranty2)
Datasheet |
User Manual |
- Measuring ranges 0 ... 2.5 kN to 0 ... 470 kN
- Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
- Piston stroke ≤ 0.5 mm, force introduction as total clamping force
- Operates without supply voltage
- 5-year leak-tightness warranty2)
Datasheet |
- Measuring ranges 0 ... 160 N to 0 ... 60 kN
- Relative linearity error ±1.0 ... ±1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor
- Piston stroke ≤ 0.5 mm
- Operates without supply voltage
- 5-year leak-tightness warranty
Datasheet |
User Manual |
- Measuring ranges 0 ... 1.1 kN to 0 ... 180 kN
- Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
- Piston stroke ≤ 0.5 mm, force introduction as total clamping force
- Operates without supply voltage
- 5-year leak-tightness warranty2)
Datasheet |