Plastic Machines

kunststoffmaschine min

Foto by Emily Bernal on Unsplash

 

The range of plastic processing machines is as extensive as the products they produce. While a facility for producing blown film, producing barrier films, breathable films, heavy-duty bags, adhesive tapes, or labels, differs significantly from an injection molding machine used for manufacturing children’s toys, housing parts, transparent vehicle headlights, or medical components, the fundamental function of all these machines is processing plastic granules. These are melted and shaped into the desired form. A central component in this process is the extruder screw, surrounded by heating sleeves that melt the granules and generate the necessary pressure for extrusion. The preparation process of the granules, including dedusting and drying, is essential as particles and moisture can significantly affect product quality.

Measuring instruments play a crucial role in various areas of plastic machinery:

  • Closing force at the injection tool is monitored by hydraulic pressure or force sensors.
  • The temperature at the injection tool and that of the plastic melt are measured by temperature sensors or thermocouples.
  • System pressure is controlled by pressure transmitters, switches, or pressure gauges.
  • The oil level in the tank is checked by float switches or optoelectronic switches.
  • The temperature of the hydraulic oil is regulated by temperature sensors or switches.

Precise measurement and control of the melt temperature are crucial for the quality of the end product, which must be kept within tight tolerances. Adequate flowability is required for efficient filling of the injection mold, with the maximum temperature not to be exceeded to avoid material damage.

The pretreatment of the granules is as necessary as the precise temperature control of the injection molding tools by external temperature control units to ensure product quality. Our measuring instruments provide accurate, robust, and reliable solutions in all these areas to support the production of high-quality plastic products. These devices are indispensable for the safe operation of the machines and the preservation of productivity by increasing process efficiency and helping to minimize downtime.

  • Measuring ranges 0 ... 1 kN to 0 ... 500 kN [0 ... 224.8 lbf to 0 ... 112,404 lbf]
  • Stainless steel version (corrosion-resistant)
  • Integrated amplifier
  • High long-term stability, high shock and vibration resistance
  • Good reproducibility, easy installation
Datasheet
User Manual

  • Measuring ranges 0 ... 10 kN to 0 ... 45 kN [0 ... 2,248 lbf to 0 ... 10,116 lbf]
  • Corrosion-resistant stainless steel design
  • Integrated amplifier
  • High long-term stability, high shock and vibration resistance
  • Good reproducibility, simple installation
Datasheet
User Manual

  • Measuring ranges 0 ... 1 kN to 0 ... 200 kN [0 ... 225 lbf to 0 ... 44,962 lbf]
  • Corrosion-resistant stainless steel design
  • Integrated amplifier
  • High long-term stability, high shock and vibration resistance
  • Good reproducibility, simple installation
Datasheet
User Manual

  • Measuring ranges 0 ... 3 kN to 0 ... 450 kN
  • Relative linearity error 2 % Fnom
  • Material: Stainless steel
  • Ingress protection IP65
Datasheet

  • Measuring ranges 0 ... 2 kN up to 0 ... 100 kN
  • For compression force measurements
  • Flat dimensions
  • Stainless steel measuring body
  • Protection class IP65
Datasheet

  • Measuring ranges 0 ... 15 kN to 0 ... 1,500 kN
  • Compact design, easy installation
  • Ingress protection IP65
  • Relative linearity error 1 % Fnom
Datasheet

  • Exclusion of potential faults during installation and operation in hot runner systems thanks to plasticencapsulated transition
  • The thermocouple can be installed without any fixing through bending or forming the sheathed cable or with a rotatable (if required, spring-loaded) union screw
  • Probe diameter 0.5 ... 3.0 mm [0.020 ... 0.118 in]
  • Kapton®, as the industry standard insulating material for connection cables
Datasheet
Bedienungsanleitung

  • Application range up to 400 °C [752 °F]
  • Insertion length and contact pressure can be adjusted through sliding bayonet cap
  • Thermocouple cable standard with glass-fibre insulation and stainless steel braid
  • Thermocouple type J or K in accordance with IEC 60584 or ASTM E230
  • Tip construction: Tubular design
Datasheet
User Manual

  • Application range up to 400 °C [752 °F]
  • Thermocouple cable standard with glass-fibre insulation and stainless steel braid
  • Thermocouple type J or K in accordance with IEC 60584 or ASTM E230
  • The manifold thermocouple is a low profile design
  • Interchangeable and easily replaceable
Datasheet
User Manual

  • The sensor is fixed with a pre-determined threaded bolt and mounted into the process
  • The nozzle thermocouples are a low profile in design
  • Extension cable is available in a variety of insulation and jacketed materials. These include fibreglass, PTFE or PVC to name a few.
  • With or without stainless steel overbraid
  • Interchangeable and easily replaceable
Datasheet
User Manual

  • Measuring ranges from 0 … 0.05 to 0 … 1,000 bar
  • Non-linearity 0.25 % or 0.5 %
  • Output 4 ... 20 mA, DC 0 ... 10 V, DC 0 ... 5 V and others
  • Electrical connection: Angular connector form A and C, circular connector M12 x 1, cable outlet 2 m
  • Process connection G ¼ A DIN 3852-E, ¼ NPT and others
Datasheet
User Manual

  • Industry 4.0-ready IO-Link sensor improves connectivity and diagnostics
  • Designed for rough demands of up to 1,000 g shock and -40 ... +125 °C [-40 ... +257 °F]
  • Optimised design makes OEM machine integration easier
  • Multicolour 360° LED status display simplifies troubleshooting and localisation
Datasheet
User Manual

  • Measuring ranges from 0 ... 6 bar to 0 ... 600 bar
  • Non-linearity 0.5 %
  • Standard industrial signals
  • Electrical connection: Angular connector form A and C, circular connector M12 x 1, Metri-Pack series 150, cable outlet 2 m unshielded or shielded
  • Many internationally customary process connections
Datasheet
User Manual

  • Measuring ranges from 0 ... 6 to 0 ... 1,000 bar [0 ... 500 to 0 ... 15,000 psi]
  • Current and voltage outputs
  • Ingress protection IP65 or IP67
  • Wetted parts and case from stainless steel
  • Vacuum-tight
Datasheet
User Manual

  • Very good vibration and shock resistance
  • Especially robust design
  • Type approval for the shipbuilding industry
  • Scale ranges to 0 ... 1,000 bar or 0 ... 15,000 psi
Datasheet
User Manual
User Manual
User Manual

  • Reliable and cost-effective
  • Design per EN 837-1 or ASME B40.100
  • Nominal size 40 [1 ½"], 50 [2"], 63 [2 ½"], 80 [3"], 100 [4"] and 160 [6"]
  • Scale ranges to 0 ... 400 bar [0 ... 6,000 psi]
Datasheet

  • Easily readable, robust digital display
  • Intuitive and fast setup
  • Easy and flexible mounting configurations
  • Flexibly configurable and scalable output signals
Datasheet
User Manual

  • Adjustable switch hysteresis
  • Setting ranges: 0.2 … 2 bar [3 ... 30 psi] to 30 ... 320 bar [450 ... 4,600 psi] and -0.85 ... -0.15 bar [-25 inHg ... -5 inHg]
  • Non-repeatability of the switch point: ≤ 2 %
  • Switching functions: Normally closed, normally open or change-over contact
  • Media: Compressed air, neutral and self-lubricating fluids and neutral gases
Datasheet

  • Good/bad indication through parameterisable digital display (red/green)
  • Compact size enables easy installation in narrow spaces
  • Optimised design makes OEM machine integration easier
  • Designed for rough demands of up to 50 g shock and -40 ... +125 °C [-40 ... +257 °F]
Datasheet
User Manual

  • Maximum reliability thanks to high-quality reed contacts
  • Very high variety and customer-specific solutions possible
  • Simple and fast installation
Datasheet
User Manual

  • Media compatibility: Oil, water, diesel, refrigerants and other liquids
  • Level: Up to 3 switching outputs, freely definable as normally open, normally closed or change-over contact
  • Temperature: 1 bimetal temperature switch or Pt100/Pt1000, accuracy: Class B
  • Potential-free switching reed contacts
Datasheet
User Manual

  • Media compatibility: Oil, water, diesel, refrigerants and other liquids
  • Permissible medium temperature range: -30 ... +120 °C [-22 ... +248 °F]
  • Output signal: Resistance in a 3-wire potentiometer circuit, current output 4 ... 20 mA
  • Measuring principle: Reed-chain technology
  • Accuracy, resolution: 24 mm [0.9 in], 12 mm [0.5 in], 10 mm [0.4 in], 6 mm [0.2 in] oder 3 mm [0.1 in]
Datasheet
User Manual

  • Media compatibility: Oil, water, diesel, refrigerants and other liquids
  • Level: Current output 4 ... 20 mA
  • Temperature: Pt100, Pt1000, accuracy: Class B
Datenblatt
Bedienungsanleitung

  • Compact design, no moving components
  • Mounting position as required
  • Accuracy ±2 mm
  • Visual indication of the switching status
  • Choice of electrical connections: PUR, PVC cable or circular connector M8 x 1
Datasheet
User Manual

  • Measuring ranges from -50 ... +250 °C [-58 ... +482 °F]
  • Very high vibration resistance
  • Compact design
  • Electrical connection via plug connection
Datasheet
User Manual

  • Sensor ranges from -196 ... +600 °C (-320 ... +1.112 °F)
  • For mounting in all standard thermowell designs
  • Spring-loaded measuring insert (replaceable)
  • Pt100 or Pt1000 sensors
  • Explosion-protected versions
 
Datasheet
User Manual
User Manual
User Manual
User Manual
User Manual

  • Sensor ranges from -196 ... +600 °C [-320 ... +1.112 °F]
  • With integrated fabricated protection tube
  • Spring-loaded measuring insert (replaceable)
  • Explosion-protected versions are available for many approval types (see data sheet page 2)


Datasheet
User Manual
User Manual
User Manual
User Manual
User Manual

  • Sensor ranges from -196 ... +500 °C [-320 ... +932 °F]
  • Compact design
  • Universal application
  • Direct installation into the process
  • Explosion-protected versions are available for many approval types (see data sheet page 2)
Datasheet
User Manual
User Manual
User Manual
User Manual
User Manual

  • Sensor ranges from -196 ... +600 °C [-320 ... +1,112 °F]
  • For insertion, screw-in with optional process connection
  • Connection head form B or JS
  • Explosion-protected versions are available for many approval types (see data sheet page 2)


Datasheet
User Manual
User Manual
User Manual
User Manual
User Manual

  • Very compact design, high vibration resistance and fast response time
  • With direct sensor output (Pt100, Pt1000 in 2-, 3- or 4-wire connection) or integrated transmitter with 4 ... 20 mA output signal
  • Integrated transmitter is individually parameterisable with free-of-charge WIKAsoft-TT PC configuration software
  • Sensor element with accuracy class A per IEC 60751


Datasheet
User Manual

  • Easily-readable, robust display
  • Intuitive and fast setup
  • Easy and flexible mounting configurations
Datasheet

  • Fully digital calibration
  • Increased speed and force range
  • Advanced electronics and software enable up to 45 shear stress or shear rate data points per test
  • Unique algorithms for polymer melt stability
  • Bidirectional communication allows downloading test parameters from the PC
  • Multiple heating zones in the cylinder and adaptive PID temperature control algorithm ensure precise and uniform heating up to 430°C (optional up to 500°C for models 7000 and 7001)
  • Precision servo motor and transducer allow for accurate control of load and speed mode tests
  • Tungsten carbide dies and a hardened and ground tool steel cylinder ensure long service life
  • LAB KARS, advanced rheology software
Datasheet
Info
Accessory

  • Fast configuration to match specific settings and default parameters of the extruder
  • Single device for heat control-only, heat/cool control, or indicator-only
  • Universal input
  • Selectable controller or indicator modes
  • Heat only or heat/cool control type
  • Process & loop alarms
  • Available in 1/16 & 1/8 DIN formats
  • Modbus RS485 communications
  • Ramping setpoint
  • Process alarms have adjustable hysteresis
  • Three alarm settings are standard and can be used for process high, process low, SP deviation, band, logical OR / AND, loop alarm for process control security
Datasheet
User Manual

  • Pressure range 0-700bar
  • Pressure port 1/2"20UNF or M18x1.5 (others on request)
  • Accuracy <0.5% FS
  • Display pressure in 13 different units
  • Battery operation for pressure display (mains voltage required for heating pressure port)
  • Battery: standard button cell, service life: >2000h in continuous operation
  • Optional data transfer to PC/notebook of the generated print via external converter possible
  • Oil volume 57ml (HLP22BP/olive oil)
  • Measuring interval 0.5 seconds
  • CE compliant/RoHS compliant
  • DKD certificate optional
  • Ambient conditions: 0...50°C/5...95% rel. humidity
  • Dimensions (LxWxH): approx. 470 x170 x 280 mm
  • Weight: approx. 7.2 kg, with case approx. 13 kg
Datasheet
User Manual

  • Pressure range: 0 - 700 bar
  • Max. Permitted pressure: FS + 10%
  • Resolution: 100 mBar (10 mBar at pressure range = 200 bar)
  • Accuracy: ± 0.05% f.s. E. (at t = 0 °C to +50 °C) +/- 1 digit
  • Measuring rate: 500 ms (2 Hz)
  • Units: including Bar / PSI / kPA / mH2O (a total of 13 different units, adjustable on the display)
  • Heated pressure port : 1/2" 20UNF or M18 x 1.5 (other ports on request)
  • Temperature at the pressure port: Adjustable from RT to +400°C on the built-in PID temperature controller
  • Oil volume: 57 ml
  • Type of oil: olive oil/HLP 22 BP
  • Power supply: 3 V battery, type CR 2430
  • Battery life: 2000 hours of continuous use
  • Interface: RS485, connecting cable K-114-A with USB port optionally available
  • Power supply for heating and sensor supply: 115 V AC or 230 V AC
  • Sensor supply (test object): via integrated power pack and plug or socket
  • Protection class: IP 65
Datasheet
User Manual

  • Mains-independent thanks to battery supply (battery life: 2000 hours in continuous operation)
  • Pressure range 0 - 700bar
  • various pressure ports available
  • Display of the pressure in 13 different units
  • Accuracy +/- 0.05% FSO
  • Resolution 100 mbar with 700 bar version
  • Versions 200/350 bar final pressure value on request
Datasheet

nicht mehr lieferbar. Nachfolger ATC990

Datasheet

no longer available. Successor model UPR 900

Datasheet

no longer available. Successor model 1490

Datasheet

no longer available. Successor model 1480

Datasheet

No longer available. Successor model SPX 4222 / SPX 4622.

Datasheet

No longer available. Successor model SPX 4222 / SPX 4622.

Datasheet

Smart pressure transmitter. FM approved models available. Intrinsically safe models available. Data sheet only available in English.

Datasheet

Smart pressure transmitter. FM approved models available. Intrinsically safe models available. Data sheet only available in English.

Datasheet

No longer available. Successor model SPX 4222 / SPX 4622.

Datasheet

Intelligente Druckmesstechnik mit Option auf Eigensicherheit und HART

Datasheet

Intelligente Druckmesstechnik mit Option für Eigensicherheit

Datasheet

Intelligent pressure measurement technology with options for intrinsic safety and HART

Datasheet

The pressure transmitters of the TDT series are based on the proven TDA series. The existing process pressure is converted into a proportional volt output signal by an integrated amplifier in three or two-wire technology. This ensures signal transmission independent of interference, even over longer distances. Thanks to the integrated thermocouple, it is possible to measure the temperature directly on the medium at the same time.

Datasheet

The new pressure transmitter series TDT was specially developed for problem-free use in critical environments with high interference potentials, whereby the 4-20mA current signal can be transmitted over long distances without interference even with connecting cables without a screen.

Datasheet

The new pressure transmitter series MDT was specially developed for problem-free use in critical environments with high interference potentials, whereby the 4-20mA current signal can be transmitted over long distances without interference, even with connecting cables without a screen. These versions have a special, short pressure sensor head with a mounting nut ½-20 UNF thread and a flexible, partially free capillary to the amplifier housing. They are therefore particularly suitable for use in confined spaces.

Datasheet

The pressure transmitters of the MDT series are based on the proven MDA series. The upcoming


Datasheet

The new pressure transmitter series MDT was specially developed for problem-free use in critical environments with high interference potentials, whereby the 4-20mA current signal can be transmitted over long distances without interference, even with connecting cables without a screen.


Datasheet

The pressure transmitters of the MDT series are based on the proven MDA series. The existing process pressure is converted into a proportional volt output signal by an integrated amplifier in three or two-wire technology. This ensures signal transmission independent of interference, even over longer distances.


Datasheet

Die Drucktransmitterserie MDT wurde speziell für den problemlosen Einsatz in kritischer Umgebung mit hohen Störpotentialen entwickelt, wobei auch bei Anschlusskabeln ohne Schirm das Stromsignal 4-20mA störsicher über weite Distanzen übertragen werden kann.
Datasheet

  • Large diaphragm and mounting flange for easier installation
  • Reduce temperature drift by ~80% over non-compensated units
  • Accuracy to ±0.15% FS
  • Temperature output available (RTD or 4-20mA)
  • HART™ digital communications
  • 0-500 to 0-10,000psi range options
  • Rugged welded electronics housing
Datasheet

  • Large diaphragm and optional split flange for easier installation
  • Reduce temperature drift by ~80% over non-compensated units
  • Accuracy to ±0.15% FS
  • Temperature output available (RTD or 4-20mA)
  • HART™ digital communications
  • 0-500 to 0-10,000psi range options
  • Rugged welded electronics housing
Datasheet

  • Large diaphragm and mounting flange for easier installation
  • Reduce temperature drift by ~80% over non-compensated units
  • Accuracy to ±0.25% FS
  • Temperature output available (RTD or 4-20mA)
  • HART™ digital communications
  • 0-500 to 0-10,000psi range options
  • Rugged welded electronics housing
Datasheet

  • Large diaphragm and optional split flange for easier installation
  • Reduce temperature drift by ~80% over non-compensated units
  • Accuracy to ±0.25% FS
  • Temperature output available (RTD or 4-20mA)
  • HART™ digital communications
  • Meets CE-PED requirements for European standards
  • 0-500 to 0-10,000psi range options
Datasheet

  • Small diaphragm and mounting flange for easier installation
  • Reduce temperature drift by ~80% over non-compensated units
  • Accuracy to ±0.15% FS
  • Temperature output available (RTD or 4-20mA)
  • HART™ digital communications
  • 0-500 to 0-10,000psi range options
  • Rugged welded electronics housing
Datasheet

  • Small diaphragm and mounting flange for easier installation
  • Reduce temperature drift by ~80% over non-compensated units
  • Accuracy to ±0.25% FS
  • Temperature output available (RTD or 4-20mA)
  • HART™ digital communications
  • 0-500 to 0-10,000psi range options
  • Rugged welded electronics housing
Datasheet

  • 1/2-20 UNF thread pressure transmitter
  • Reduce temperature drift by ~80% over non-compensated units
  • Accuracy to ±0.15% FS
  • Temperature output available (RTD or 4-20mA)
  • HART™ digital communications
  • 0-500 to 0-10,000psi range options
  • Rugged welded electronics housing
Datasheet

  • 1/2-20 UNF thread pressure transmitter
  • Reduce temperature drift by ~80% over non-compensated units
  • Accuracy to ±0.25% FS
  • Temperature output available (RTD or 4-20mA)
  • HART™ digital communications
  • 0-500 to 0-10,000psi range options
  • Rugged welded electronics housing
Datasheet

  • Simple and inexpensive 2-wire connection, unshielded in the toughest interference field environment
  • ATEX approval: II 2 G EEx ia IIC T4
  • Meets NAMUR regulations NE21 and NE43
  • Smart transmitter with HARTTM communication
  • 0.5% accuracy
  • Pressure measuring ranges 0-100 to 0 - 2000 bar
  • Process temperature up to 400°C
  • Autozero and Autocal
Datasheet

  • Simple and inexpensive 2-wire connection, unshielded in the toughest interference field environment
  • ATEX approval: II 2 G EEx ia IIC T4
  • Meets NAMUR regulations NE21 and NE43
  • Smart transmitter with HARTTM communication
  • Series with 0.25% and 0.5% accuracy
  • Pressure measuring ranges 0-70 to 0 - 2000 bar
  • Process temperature up to 400°C
  • Autozero and Autocal
Datasheet

  • HART digital communication
  • Better than +/- 0.25% combined error
  • 4 - 20 mA loop-powered output
  • 0 - 250 to 0 -30,000 psi
  • Explosion Proof, Intrinsically Safe/ATEX approved*
  • Meets PED and CE requirements
  • Configurable via handheld
  • Precise repeatable pressure measurments
  • Output supplied directly to DCS or PLC
  • Customer defined pressure ranges
  • Approved for hazardous environments
  • Meets new EC requirements
Datasheet

  • Better than ±0.5% accuracy
  • 4 to 20 mA, 0 to 5 Vdc, 1 to 6 Vdc, 0 to10 Vdc, 1 to 11 Vdc outputs
  • Stainless steel, Armoloy coated
  • 0 - 500 to 0 - 30,000 psi
  • Internal 80% shunt calibration
  • Adjustable zero and span
  • Integral thermocouple
  • Reliable pressure measurement
  • Direct input to supervisory control systems
  • Minimizes thread galling, abrasion resistant
  • Choice of pressure ranges
  • Easy set-up
  • Adapt transmitter to process conditions
  • Simultaneously measure pressure/temperature in one location
 
Datasheet

  • Better than ±0.5% accuracy
  • 4 to 20 mA, 0 to 5 Vdc, 1 to 6 Vdc, 0 to10 Vdc, 1 to 11 Vdc outputs
  • Stainless steel, Armoloy coated
  • 0 - 500 to 0 - 30,000 psi
  • Internal 80% shunt calibration
  • Adjustable zero and span
  • Integral thermocouple
  • Reliable pressure measurement
  • Direct input to supervisory control systems
  • Minimizes thread galling, abrasion resistant
  • Choice of pressure ranges
  • Easy set-up
  • Adapt transmitter to process conditions
  • Simultaneously measure pressure/temperature in one location
 
Datasheet

  • Better than ±0.5% accuracy
  • 4 to 20 mA, 0 to 5 Vdc, 1 to 6 Vdc, 0 to10 Vdc, 1 to 11 Vdc outputs
  • Stainless steel, Armoloy coated
  • 0 - 500 to 0 - 30,000 psi
  • Internal 80% shunt calibration
  • Adjustable zero and span
  • Integral thermocouple
  • Reliable pressure measurement
  • Direct input to supervisory control systems
  • Minimizes thread galling, abrasion resistant
  • Choice of pressure ranges
  • Easy set-up
  • Adapt transmitter to process conditions
  • Simultaneously measure pressure/temperature in one location
 
Datasheet

The pressure transmitters of the TDA series are based on the proven MDA series. They supply an output signal that is proportional to the process pressure via a closed, liquid-filled diaphragm seal system. Thanks to the integrated thermocouple, it is possible to measure the temperature directly on the medium at the same time.

Datasheet

  • Installation for media temperature up to 400 °C
  • l Integral thermocouple for simultaneous temperature measurement at the media
  • l Flexible capillary between rigid stem and housing
  • l Liquid-filled transmission system
  • l Electrical built-in calibration
 
Datasheet

  • Installation for media temperature up to 400 °C
  • l Flexible capillary between rigid stem and housing
  • l Liquid-filled transmission system
  • l Electrical built-in calibration
 
Datasheet

  • Installation for media temperature up to 400 °C
  • l Flexible capillary between rigid stem and housing
  • l Liquid-filled transmission system
  • l Electrical built-in calibration
 
Datasheet

  • Accuracy better than +/- 0.5%
  • Dymax® coated stainless steel wetted parts
  • Proven sensor design
  • 0 - 500 to 0 -30,000 psi
  • Internal 80% shunt calibration
  • Reliable, repeatable pressure measurements
  • Superior abrasion resistance
  • Good stability and repeatability
  • Wide variety of pressure ranges
  • Easy to calibrate with local indicator
 
Datasheet

Die Druckaufnehmer der Serie MDA liefern über ein geschlossenes, flüssigkeitsgefülltes Druckmittlersystem ein zum anstehenden Prozessdruck proportionales Ausgangssignal.

Datasheet

The pressure transducers of the MDA series supply an output signal that is proportional to the process pressure via a closed, liquid-filled diaphragm seal system.
Datasheet

  • Sensor extends into process
  • Type J thermocouple output
  • 1/2 - 20 UNF mounting
  • 0 to 900°F range
  • Flush to 1" immersion lengths
  • Better measurement
  • Standard output
  • Fits in standard thermowell
  • Wide range of measurements
  • Immersion lengths to match applications
Datasheet

  • Type J thermocouple
  • 0 to 900°F range
  • Fiberglass insulated element
  • Adjustable brass or bayonet fitting
  • Standard output
  • Wide range of measurements
  • Protects the wire
  • Application versatility
Datasheet

  • Spring or armor adjustable
  • 0 to 900°F measurement range
  • 5 foot and 10 foot lengths
  • Fiberglass insulated element
  • Application versatility
  • Wide range of measurements
  • Handles standard application requirements
  • Protects the wire
Datasheet

  • TC Junction can be centered in hot melt stream
  • Retractable from flush to 2.5”
  • Up to 900°F melt temperatures
  • All stainless steel construction
  • Exposed junction
  • 1/2-20 UNF mounting configuration
Datasheet
User Manual

  • rugged but easy to carry
  • weight 3.9 kg only
  • accuracy +/- 0.1%
  • battery powered > 200 days
  • multiple pressure adaptors available
  • pressure range of 0 - 700 bar
  • switch selectable bar / PSI / kPA
  • memory function up to 900 measurements
  • serial communications
  • various display and test functions
Datasheet
User Manual

The Dynisco Transducer Mounting Hole Machining Tool Kit contains all of the necessary drills and taps to prepare a standard 1/2 - 20 UNF transducer mounting hole and the 45 degree seat. All tools included in this kit are made of premium grade, high strength tool steel. Care should be taken in the use of proper speeds and feeds, lubricants, and a method to assure continual alignment of each progressing tool. M10 and M18 kits are also available.

Datasheet

Selectable transducer output sensitivity Standard 6 pin Bendix connector 5 step linear output 0 – 100% Identifies faulty components in a measurement loop

Datasheet
User Manual

The cable assemblies provide the electrical hookup from the transducer to the display instrumentation. The assemblies consist of a transducer mating connector and a length of shielded, 6 conductor cable with stripped leads.

Datasheet

Each Button Seal Process Adapter is made to order depending on the provided process mounting port sizing. Flange attachments are available as one piece solid construction, threaded, or threaded & welded. Flange design is application specific and dependent on the process sizing needs of diameter, thickness, bolt-hole diameter, mounting bolt pattern.

Datasheet

Installation of transducers into improperly cleaned or sized holes is one of the major causes of damage to these instruments. With this kit, the .312" tip diameter hole, the 45 degree seating surface, and the .451" hole can be cleaned. The kit includes a gauging plug which is used to verify that the hole has been correctly machined and cleaned. M10 and M18 cleaning kits also available.

Datasheet
User Manual

  • Direct, local readings
  • Mechanical design
  • Step-up and stem-down versions
  • Gauge head rotates 300°
  • 0 - 5,000 or 0 -10,000 psi
  • Stainless steel construction
Datasheet
User manual

  • Dual 5-digit display
  • Peak display function and digital auto-zero
  • Programmable alarm relays
  • Optional 4 - 20 mA, 0 - 10 Vdc retransmission
  • Accuracy better than ±0.5%
  • Customer definable engineering units
Datasheet
Datasheet
User manual

  • Field selectable input/output ranges
  • Adapts to a variety of applications
  • Non - interactive zero and span adjustment
  • Adjust once
  • Optically isolated output
  • Free from internal interference
  • Convenient shunt calibration switch
  • Convenient matching to transducer
  • LIfetime warranty • No service problems
Datasheet
User manual

  • Each welded assembly consists of a threaded tubular body with a rupture disk welded onto the process end
  • Welded one piece assembly – no degradation of joint strength at elevated temperatures
  • Iconel rupture disk – stable through a wide range of temperatures
  • Burst ratings 750 to 15,000 psig (for higher pressures contact Dynisco)
  • Burst tolerance ±10%
  • Typical Standard Deviation is ±1%
  • 100% leak tested
  • 100% electronic thread verification
Datasheet
User manual

  • Welded one piece assembly - no degradation of joint strength at elevated temperatures
  • Inconel rupture disk – stable through a wide range of temperatures
  • Burst pressure ranges from 1,000 to 15,000psi
  • Accuracy of ±10% of rated burst pressure at 300° – 750°F
  • Designed for melt temperatures up to 800°F (425°C)
  • Leak rate exceeds 1x10-6 standard cc/sec
Datasheet
User manual

  • 4-20mA loop-powered output
  • +/- 0.25% accuracy available
  • Wide selection of pressure ranges available
  • Turndown 3:1
  • Configurations available for use in hazardous locations
  • Remotely configurable via HARTTM
  • Precise, repeatable pressure measurements
  • Output supplied directly to DSC or PLC
  • Meets CE requirements
  • CE ATEX Intrinsically Safe Approved
  • FM Explosion Proof Approved
  • CSA Explosion Proof Approved
  • SIL 2 Certified (Pressure Output)
  • PL'c' Certified (Relay Output)
  • Additional approvals are available
Datasheet
User Manual

  • 3 mv/v full scale output
  • Accuracy ±0.50%
  • Pressure ranges 0-1,000 PSI to 0-30,000 PSI
  • Iconel 718 pressure fitting
  • Zero volume pressure port
  • Meets cleanability standards
  • Metal-to-metal pressure seal
  • Internal 80% shunt calibration
  • CE approved
Datasheet
User Manual

  • Flush diaphragm
  • Accuracy ±0.50%
  • Zero volume pressure port
  • 15 to 10,000 psi
  • 3 mV/V output
  • Internal shunt calibration
Datasheet
User Manual

  • Accuracy ±0.25%
  • Stainless steel construction
  • Heavy duty construction
  • Ranges 0-110 PSI through 0-750 PSI
  • Advanced electronic de