Dynisco LCR7000/7001/7002 Laboratory Capillary Rheometers
The Dynisco LCR7000/7001/7002 Series consists of laboratory capillary rheometers for sophisticated rheological material characterization. The instruments are designed for precise measurement of melt viscosity, shear rate, shear stress and other material properties, making them suitable for research, development, quality control and material testing applications.
The LCR Series combines high measurement accuracy with versatile evaluation capabilities. Digital calibration, precision servo-drive technology, adaptive PID temperature control and advanced software allow complex test procedures to be performed reliably. Depending on the model, different barrel, force measurement and pressure measurement configurations are available.
LAB KARS software enables test data to be acquired, evaluated and documented. The software supports Bagley and Rabinowitsch corrections, Carreau, Modified Cross, Power Law and polynomial curve fits, as well as evaluations of shear rate dependence, time-at-temperature relationship, critical shear stress and intrinsic viscosity.
| Model | Description | Options for Special Requirements |
|---|---|---|
| LCR7000 | Capillary rheometer with load cell, cleaning and operating tools and one tungsten carbide orifice. | Corrosion-resistant alloy barrel for corrosive materials such as PVC; tungsten carbide dies with a wide range of diameters and L/D ratios; laser micrometer for measuring die swell as the extrudate exits the die. |
| LCR7001 | Capillary rheometer with load cell, barrel-mounted pressure transducer and long barrel, including cleaning and operating tools and three tungsten carbide orifices. | Corrosion-resistant alloy barrel for corrosive materials such as PVC; tungsten carbide dies with a wide range of diameters and L/D ratios; melt pressure transducer mounted just above the die to reduce frictional and barrel pressure effects; laser micrometer for die swell measurement. |
| LCR7002 | Dual-bore capillary rheometer with barrel-mounted pressure transducers, cleaning and operating tools and four tungsten carbide dies. | Designed for advanced testing with two pressure transducers and broad die configuration options. Suitable for more detailed material analysis and extended rheological evaluations. |
| Physical Specifications LCR7000 | |
|---|---|
| Standards | DIN ISO 11443, DIN 53014, DIN 54811, ASTM D3835 |
| Barrel | Length 7.0″ / 162 mm; Ø 0.376″ ±0.0002″ / 9.55 mm ±0.005 mm |
| Drive system | DC servomotor |
| Piston speed | 0.03…600 mm/min |
| Dynamic range | 20,000:1 |
| Testing force | 10 kN standard, 0.2 N resolution; 15 kN optional |
| Force measurement | Load cell |
| Dies | Tungsten carbide capillary, many L/D ratios available |
| Die swell measurement | Laser micrometer optional |
| Temperature range | Up to 430 °C standard |
| Temperature control | 4-zone electric heater |
| Temperature sensor | 4-wire platinum RTD |
| Temperature control algorithm | Adaptive PID temperature control algorithm with 0.1 °C resolution |
| Temperature accuracy | ±0.2 °C at 0.50″ / 13 mm |
| Ambient temperature | 20…30 °C |
| Relative humidity | 20…80 % |
| Voltage | 10 % of nominal voltage |
| Power supply | 115/230 VAC, 50/60 Hz |
| Power consumption | 750 W max., 200 W typical |
| Data processing system | PC-based |
| System software | LAB KARS for Windows, Kayeness Advanced Rheology Software |
| Physical Specifications LCR7001 | |
|---|---|
| Standards | DIN ISO 11443, DIN 53014, DIN 54811, ASTM D3835 |
| Barrel | Length 7.88″ / 200 mm; Ø 0.376″ ±0.0002″ / 9.55 mm ±0.005 mm |
| Drive system | DC servomotor |
| Piston speed | 0.03…650 mm/min |
| Dynamic range | 20,000:1 |
| Testing force | 10 kN standard, 0.2 N resolution, per bore |
| Force measurement | System has 1 load cell and 1 pressure transducer |
| Dies | Many diameters and L/D ratios available |
| Temperature range | Up to 430 °C |
| Temperature control | 4-zone electric heater |
| Temperature sensor | 4-wire platinum RTD |
| Temperature control algorithm | Adaptive PID temperature control algorithm with 0.1 °C resolution |
| Temperature accuracy | ±0.2 °C at 0.50″ / 13 mm |
| Ambient temperature | 20…30 °C |
| Relative humidity | 20…80 % |
| Voltage | 10 % of nominal voltage |
| Power supply | 115/230 VAC, 50/60 Hz |
| Power consumption | 750 W max., 200 W typical |
| Data processing system | PC-based |
| System software | LAB KARS for Windows, Kayeness Advanced Rheology Software |
| Physical Specifications LCR7002 | |
|---|---|
| Standards | DIN ISO 11443, DIN 53014, DIN 54811, ASTM D3835 |
| Barrel | Length 7.88″ / 200 mm; Ø 0.376″ ±0.0002″ / 9.55 mm ±0.005 mm |
| Drive system | DC servomotor |
| Piston speed | 0.03…650 mm/min |
| Dynamic range | 20,000:1 |
| Testing force | 10 kN standard, 0.2 N resolution; 15 kN optional |
| Force measurement | System has 2 pressure transducers |
| Dies | Many diameters and L/D ratios available |
| Die swell measurement | Laser micrometer optional |
| Temperature range | Up to 430 °C standard |
| Temperature control | 4-zone electric heater |
| Temperature sensor | 4-wire platinum RTD |
| Temperature control algorithm | Adaptive PID temperature control algorithm with 0.1 °C resolution |
| Temperature accuracy | ±0.2 °C at 0.50″ / 13 mm |
| Ambient temperature | 20…30 °C |
| Relative humidity | 20…80 % |
| Voltage | 10 % of nominal voltage |
| Power supply | 115/230 VAC, 50/60 Hz |
| Power consumption | 750 W max., 200 W typical |
| Data processing system | PC-based |
| System software | LAB KARS for Windows, Kayeness Advanced Rheology Software |
| Option / Accessory | Description |
|---|---|
| D7052DS2 | Laser micrometer die swell measuring system |
| GP8000C | Personal computer with LAB KARS for Windows software installed |
| GP7984C | Colour printer |
| 8052-155 | Pressure transducer port cleaning kit |
| 8052-97K | Barrel cleaning kit, 110 V |
| 8052-97KE | Barrel cleaning kit, 230 V |
| GRAN | High speed mini granulator |
| BTP1000A | Barrel temperature calibration kit, 110 V |
| BTP1000AHV | Barrel temperature calibration kit, 230 V |
| 8052-65BG | Barrel bore verification kit |
| D7992 | Electronic load cell calibration kit |

Datasheet