Echo- Series-NaK Alternate Fill


  • Alternative fill model available
  • Accuracy better than ±0.5%
  • TiAlN diaphragm coating is standard
  • mV/V, 0-10VDC, or mA outputs available
  • Integral temperature sensor option
  • Available in configurations that fit most extruder applications
  • 1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability
Datasheet
User Manual

Echo sensors are designed to meet customer requirements by providing a combination of economic value and performance for general extrusion applications while providing a ±0.2% repeatability when measuring process pressures. Use Echo Series sensors when the application requires a quality measurement for optimized control, but not the costs of all the extra features.

⚠ WARNING: This product can expose you to chemicals including mercury and lead, which is known to the State of California to cause cancer and reproductive harm. For more information, go to www.P65Warnings.ca.gov.









Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    Echo- Series-NaK Alternate Fill

    • Alternative fill model available
    • Accuracy better than ±0.5%
    • TiAlN diaphragm coating is standard
    • mV/V, 0-10VDC, or mA outputs available
    • Integral temperature sensor option
    • Available in configurations that fit most extruder applications
    • 1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability
    Datasheet
    User Manual

    Echo sensors are designed to meet customer requirements by providing a combination of economic value and performance for general extrusion applications while providing a ±0.2% repeatability when measuring process pressures. Use Echo Series sensors when the application requires a quality measurement for optimized control, but not the costs of all the extra features.

    ⚠ WARNING: This product can expose you to chemicals including mercury and lead, which is known to the State of California to cause cancer and reproductive harm. For more information, go to www.P65Warnings.ca.gov.