Dynisco PT42X Series
The Dynisco PT42X Series includes pressure transducers with an additional flexible capillary tube between the strain gauge housing and the rigid stem. The PT422 and PT462 models are designed for applications where the strain gauge element cannot be mounted directly near the process due to high process temperatures, or where a flexible connection between the measuring point and the housing is required.
The sensors are suitable for media temperatures up to 400 °C and feature a liquid-filled transmission system. Pressure measurement is based on a four-arm Wheatstone bridge strain gauge. The integrated electrical shunt calibration allows the measuring signal to be checked easily. Depending on the accuracy requirement, the PT422 model with ±0.5 % accuracy and the PT462 model with ±1.0 % accuracy are available.
The PT42X Series covers pressure ranges from 0…250 psi to 0…30,000 psi. The material in contact with the media is 15-5 stainless steel, material no. 1.4545. Mounting thread versions 1/2-20 UNF-2A or M18 × 1.5 are available. The 6/18 option describes a rigid length of 6″ and a flexible length of 18″ between the rigid stem and the housing.
| Type | Pressure transducer with flexible capillary connection |
|---|---|
| Series | Dynisco PT42X Series |
| Models | PT422 and PT462 |
| Application | Pressure measurement at high media temperatures or in applications requiring a flexible connection between sensor stem and housing |
| Pressure range | 0…250 psi to 0…30,000 psi |
| Accuracy PT422 | ±0.5 % F.S.V.; up to 750 psi ±1 % F.S.V. |
| Accuracy PT462 | ±1 % F.S.V. |
| Repeatability PT422 | ±0.1 % F.S.V.; up to 750 psi ±0.2 % F.S.V. |
| Repeatability PT462 | ±0.2 % F.S.V. |
| Resolution | Infinite |
| Maximum overload | 2 × pressure range; for 15,000 and 20,000 psi ranges, max. 30,000 psi; for 30,000 psi range, max. 35,000 psi |
| Burst pressure | 6 × pressure range, max. 45,000 psi |
| Material in contact with media | 15-5 stainless steel, material no. 1.4545 |
| Configuration | Four-arm Wheatstone bridge strain gauge |
| Strain resistance | 350 Ω |
| Output signal | 3.33 mV/V |
| Zero balance | ±5 % F.S.V., adjustable |
| Supply voltage | 10 VDC, max. 12 VDC |
| Internal shunt calibration | 80 % F.S.V. ±0.5 % |
| Leakage resistance | 1000 MΩ at 50 VDC |
| Max. diaphragm temperature | 400 °C |
| Diaphragm zero shift due to temperature change | PT422 < 27 psi / 10 °C; PT462 < 45 psi / 10 °C |
| Max. housing temperature | 120 °C |
| Housing zero shift due to temperature change | PT422 ±0.2 % F.S.V. / 10 °C; PT462 ±1.0 % F.S.V. / 10 °C |
| Sensitivity shift due to temperature change | PT422 ±0.1 % F.S.V. / 10 °C; up to 750 psi ±0.2 % F.S.V. / 10 °C; PT462 ±0.4 % F.S.V. / 10 °C |
| Pressure connection | 1/2-20 UNF-2A or M18 × 1.5 |
| Stem version | Rigid stem with flexible capillary |
| Rigid length / flexible length | Option 6/18: rigid length 6″ and flexible length 18″ between rigid stem and housing |
| Pressure range codes | 2.5C: 0…250 psi | 5C: 0…500 psi | 7.5C: 0…750 psi | 1M: 0…1,000 psi | 1.5M: 0…1,500 psi | 3M: 0…3,000 psi | 5M: 0…5,000 psi | 7.5M: 0…7,500 psi | 10M: 0…10,000 psi | 15M: 0…15,000 psi | 20M: 0…20,000 psi | 30M: 0…30,000 psi |
| Accessories | Indicator 1290, Process Readout UPR700, Process Controller ATC770, Cleaning Tool Kit, Machining Tool Kit |

Datasheet