1490 Panel Indicator – Universal 5-digit 1/8 DIN indicator for process signals


  • Dynisco 1490 with universal input for thermocouples, PT100, strain gauge and DC linear signals
  • Up to two programmable alarms available
  • Optional analog output for retransmission of the process variable
  • Optional 24 VDC transmitter supply
  • Modbus communication via 2-wire RS485
  • Peak value memory for minimum and maximum values
  • 3-button operation with bright 5-digit 13 mm LED display
  • Scalable display range from 1999 to 9999 with adjustable decimal point
  • IEC IP66 front panel protection for industrial applications
Datasheet

Dynisco 1490 5-Digit 1/8 DIN Indicator

The Dynisco 1490 is a universal 5-digit indicator in a 1/8 DIN format for displaying different process signals. It is suitable for plastics processing and industrial measurement systems where process values such as pressure, temperature or other analog signals need to be displayed and monitored reliably.

The universal input supports thermocouples, PT100, strain gauge sensors and DC linear signals. This allows the indicator to be flexibly adapted to different sensing and measurement tasks. Values are displayed on a bright 5-digit 13 mm LED display, supported by status indications for up to two alarms as well as minimum and maximum values.

The Dynisco 1490 can optionally be equipped with analog output, transmitter supply and Modbus communication. This allows process variables to be retransmitted to other devices, sensors to be powered directly, or the unit to be integrated into higher-level systems via an RS485 interface. Two process alarms with adjustable hysteresis support simple limit monitoring.

Type Universal 5-digit 1/8 DIN indicator
Series Dynisco 1490
Model 1490
Application Display and monitoring of process variables, pressure, temperature and analog process signals
Output configuration 1 or 2 relay outputs, optional analog output
Alarms 2 process alarms high / low with adjustable hysteresis
Visible values Process variable, maximum value and minimum value
Operation 3 buttons
Display 5-digit 13 mm high display, red or green, with 2 alarm displays
Thermocouple inputs J, K, C, R, S, T, B, L, N and PtRh20% versus PtRh40%
PT100 input 3-wire PT100, 50 Ω maximum per lead
Strain gauge input 350 Ω strain gauge
Strain gauge bridge connection 4 or 6 wires, 6-wire for internal shunt calibration
Strain gauge bridge voltage 10 V ±7 %
Strain gauge bridge sensitivity 1.4…4 mV/V
Strain gauge input signal range -25 % to +125 % of full scale, approx. +10 mV to +50 mV
Strain gauge calibration Internal switch between CAL2 and CAL1 terminals, external resistor only
Strain gauge shunt value 40 % to 100 %
DC linear input 0…20 mA, 4…20 mA, 0…50 mV, 10…50 mV, 0…5 V, 1…5 V, 0…10 V, 2…10 V
Scaling 1999 to 9999, with adjustable decimal point
Impedance >10 MΩ for thermocouple and mV range, 47 kΩ for V range and 50 Ω for mA range
Accuracy ±0.1 % of input range ±1 LSD; T/C CJC better than 1 °C
Sampling rate 10 per second, approximately 16-bit resolution; 100 ms sampling time
Sensor break detection <2 seconds, except zero-based DC ranges
Sensor break behavior High alarms active for T/C, PT100 and mV ranges; low alarms active for mA or V ranges
Alarm relay Single relay contact SPDT up to 2 A at 240 VAC; dual relay SPST up to 2 A at 240 VAC
Relay lifetime >500,000 operations for single relay; >200,000 operations for dual relay
Analog output 0…20 mA, 4…20 mA up to 500 Ω max.; 0…10 V
Analog outputs 2 to 10 V, 0 to 5 V up to 500 Ω min.
Analog output resolution 15 3/4 bit, 1 part in 52K, refreshed in approximately 65 ms intervals
Analog output response time 130 ms
Analog output stability ±76 ppm
Transmitter supply 24 VDC nominal, at minimum 910 Ω of the device to be supplied
Serial communications 2-wire RS485, 1200 to 19200 Baud, Modbus
Logic input External reset of linked relay, stored alarm, one enable sequence per stored min./max. process variable or started tare function
Logic input transition HIGH 3…5 VDC to LOW <0.8 VDC or open-to-closed transition
Operating temperature 0…55 °C
Storage temperature -20…80 °C
Humidity 20…95 %, non-condensing
Power supply 85…264 V, 50/60 Hz, 7.5 VA; optional 20…48 VAC, 7.5 VA or 22…65 VDC, 5 W
Front panel protection IEC IP66; behind front panel protection IP20
Standards CE, Pollution Degree 2, Installation Category II, UL Listed
Key features Universal input, 2 alarms, analog output, Modbus communication, transmitter supply, peak value memory




Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    1490 Panel Indicator – Universal 5-digit 1/8 DIN indicator for process signals

    • Dynisco 1490 with universal input for thermocouples, PT100, strain gauge and DC linear signals
    • Up to two programmable alarms available
    • Optional analog output for retransmission of the process variable
    • Optional 24 VDC transmitter supply
    • Modbus communication via 2-wire RS485
    • Peak value memory for minimum and maximum values
    • 3-button operation with bright 5-digit 13 mm LED display
    • Scalable display range from 1999 to 9999 with adjustable decimal point
    • IEC IP66 front panel protection for industrial applications
    Datasheet

    Dynisco 1490 5-Digit 1/8 DIN Indicator

    The Dynisco 1490 is a universal 5-digit indicator in a 1/8 DIN format for displaying different process signals. It is suitable for plastics processing and industrial measurement systems where process values such as pressure, temperature or other analog signals need to be displayed and monitored reliably.

    The universal input supports thermocouples, PT100, strain gauge sensors and DC linear signals. This allows the indicator to be flexibly adapted to different sensing and measurement tasks. Values are displayed on a bright 5-digit 13 mm LED display, supported by status indications for up to two alarms as well as minimum and maximum values.

    The Dynisco 1490 can optionally be equipped with analog output, transmitter supply and Modbus communication. This allows process variables to be retransmitted to other devices, sensors to be powered directly, or the unit to be integrated into higher-level systems via an RS485 interface. Two process alarms with adjustable hysteresis support simple limit monitoring.

    Type Universal 5-digit 1/8 DIN indicator
    Series Dynisco 1490
    Model 1490
    Application Display and monitoring of process variables, pressure, temperature and analog process signals
    Output configuration 1 or 2 relay outputs, optional analog output
    Alarms 2 process alarms high / low with adjustable hysteresis
    Visible values Process variable, maximum value and minimum value
    Operation 3 buttons
    Display 5-digit 13 mm high display, red or green, with 2 alarm displays
    Thermocouple inputs J, K, C, R, S, T, B, L, N and PtRh20% versus PtRh40%
    PT100 input 3-wire PT100, 50 Ω maximum per lead
    Strain gauge input 350 Ω strain gauge
    Strain gauge bridge connection 4 or 6 wires, 6-wire for internal shunt calibration
    Strain gauge bridge voltage 10 V ±7 %
    Strain gauge bridge sensitivity 1.4…4 mV/V
    Strain gauge input signal range -25 % to +125 % of full scale, approx. +10 mV to +50 mV
    Strain gauge calibration Internal switch between CAL2 and CAL1 terminals, external resistor only
    Strain gauge shunt value 40 % to 100 %
    DC linear input 0…20 mA, 4…20 mA, 0…50 mV, 10…50 mV, 0…5 V, 1…5 V, 0…10 V, 2…10 V
    Scaling 1999 to 9999, with adjustable decimal point
    Impedance >10 MΩ for thermocouple and mV range, 47 kΩ for V range and 50 Ω for mA range
    Accuracy ±0.1 % of input range ±1 LSD; T/C CJC better than 1 °C
    Sampling rate 10 per second, approximately 16-bit resolution; 100 ms sampling time
    Sensor break detection <2 seconds, except zero-based DC ranges
    Sensor break behavior High alarms active for T/C, PT100 and mV ranges; low alarms active for mA or V ranges
    Alarm relay Single relay contact SPDT up to 2 A at 240 VAC; dual relay SPST up to 2 A at 240 VAC
    Relay lifetime >500,000 operations for single relay; >200,000 operations for dual relay
    Analog output 0…20 mA, 4…20 mA up to 500 Ω max.; 0…10 V
    Analog outputs 2 to 10 V, 0 to 5 V up to 500 Ω min.
    Analog output resolution 15 3/4 bit, 1 part in 52K, refreshed in approximately 65 ms intervals
    Analog output response time 130 ms
    Analog output stability ±76 ppm
    Transmitter supply 24 VDC nominal, at minimum 910 Ω of the device to be supplied
    Serial communications 2-wire RS485, 1200 to 19200 Baud, Modbus
    Logic input External reset of linked relay, stored alarm, one enable sequence per stored min./max. process variable or started tare function
    Logic input transition HIGH 3…5 VDC to LOW <0.8 VDC or open-to-closed transition
    Operating temperature 0…55 °C
    Storage temperature -20…80 °C
    Humidity 20…95 %, non-condensing
    Power supply 85…264 V, 50/60 Hz, 7.5 VA; optional 20…48 VAC, 7.5 VA or 22…65 VDC, 5 W
    Front panel protection IEC IP66; behind front panel protection IP20
    Standards CE, Pollution Degree 2, Installation Category II, UL Listed
    Key features Universal input, 2 alarms, analog output, Modbus communication, transmitter supply, peak value memory




    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.