SPX2242 – is a smart 4 – 20 mA pressure transmitter designed for use in hazardous locations


  • Smart 4…20 mA pressure transmitter for hazardous locations
  • SPX2242 model with optional HART™ communication
  • All-welded construction with 1/2-20 UNF threaded connection
  • Accuracy better than ±0.25 % FSO
  • Pressure ranges from 0…250 psi to 0…30,000 psi
  • 4…20 mA loop-powered output for direct connection to DCS or PLC
  • Explosion proof and ATEX / intrinsically safe versions available
  • Optional thermocouple or RTD configurations for melt temperature measurement
  • Configurable via handheld communicator
  • Standard wetted parts made of DyMax™ coated 15-5 PH stainless steel

Datasheet
Videos

Dynisco SPX2242 Pressure Transmitter

The Dynisco SPX2242 is a smart 4…20 mA pressure transmitter for precise pressure measurement in hazardous locations. The all-welded construction is designed for demanding industrial applications and features a 1/2-20 UNF thread for installation in standard transducer mounting holes.

The loop-powered 4…20 mA output allows direct connection to DCS, PLC and other high-level control systems. Optional HART™ communication is available, enabling configuration via a handheld communicator. The integrated signal conditioning eliminates the need for additional external signal conditioning in many applications.

The SPX2242 is available in explosion proof and ATEX / intrinsically safe versions. The SPX2242S intrinsically safe version is approved for II 1 G 100a Ex ia IIC, Zones 0 and 1. The SPX2242E explosion proof version is approved for Class I, Division I, Groups A, B, C and D. Optional thermocouple or RTD configurations are available to provide melt temperature measurement.

Type Smart 4…20 mA pressure transmitter for hazardous locations
Series Dynisco SPX2242
Model SPX2242
Application Pressure measurement in hazardous locations, plastics processing and industrial process plants
Process connection 1/2-20 UNF thread for standard transducer mounting holes
Output signal 4…20 mA, optionally with HART™ communication
Input voltage, standard 16…36 VDC
Input voltage, ATEX / intrinsically safe applications 16…30 VDC
Pressure ranges 0…250 psi to 0…30,000 psi
Accuracy ±0.25 % FSO; ±0.5 % FSO for ranges below 1,500 psi, including linearity, repeatability and hysteresis
Repeatability ±0.1 % FSO
Rangeability 3:1 turndown
Over pressure 2 × FSO or 35,000 psi, whichever is less
Zero balance adjustment range -40 % to +10 %; -80 % to +20 % for ranges <500 psi
Gain span adjustment range ±2 % FSO maximum
Load resistance 500 Ω at 26 VDC; 1000 Ω at 36 VDC
Maximum diaphragm temperature 750 °F / 400 °C
Zero shift due to diaphragm temperature change 15 psi / 100 °F typical or 27 psi / 100 °C
Electronics operating temperature -20…185 °F / -29…85 °C
Compensated electronics temperature range 0…150 °F / -18…65 °C
Zero and span shift due to temperature change Each 0.01 % FS / °F max. or 0.02 % FS / °C max.
Mounting torque 500 inch/lbs maximum
Standard wetted parts DyMax™ coated 15-5 PH stainless steel
Explosion proof version SPX2242E, Class I, Division I, Groups A, B, C and D; conduit fitting version
ATEX / intrinsically safe version SPX2242S, II 1 G 100a Ex ia IIC, Zones 0 and 1
ATEX / intrinsically safe connection options Conduit fitting or hermetically sealed 6-pin Bendix connector
Optional temperature measurement Thermocouple or RTD configurations available for melt temperature measurement
Configuration Configurable via handheld communicator
Approvals and requirements Explosion proof, ATEX / intrinsically safe, meets PED and CE requirements
Key features HART™ communication, 4…20 mA loop-powered output, 3:1 turndown, intrinsically safe and explosion proof versions, direct connection to DCS or PLC





More documents




Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    SPX2242 – is a smart 4 – 20 mA pressure transmitter designed for use in hazardous locations

    • Smart 4…20 mA pressure transmitter for hazardous locations
    • SPX2242 model with optional HART™ communication
    • All-welded construction with 1/2-20 UNF threaded connection
    • Accuracy better than ±0.25 % FSO
    • Pressure ranges from 0…250 psi to 0…30,000 psi
    • 4…20 mA loop-powered output for direct connection to DCS or PLC
    • Explosion proof and ATEX / intrinsically safe versions available
    • Optional thermocouple or RTD configurations for melt temperature measurement
    • Configurable via handheld communicator
    • Standard wetted parts made of DyMax™ coated 15-5 PH stainless steel

    Datasheet
    Videos

    Dynisco SPX2242 Pressure Transmitter

    The Dynisco SPX2242 is a smart 4…20 mA pressure transmitter for precise pressure measurement in hazardous locations. The all-welded construction is designed for demanding industrial applications and features a 1/2-20 UNF thread for installation in standard transducer mounting holes.

    The loop-powered 4…20 mA output allows direct connection to DCS, PLC and other high-level control systems. Optional HART™ communication is available, enabling configuration via a handheld communicator. The integrated signal conditioning eliminates the need for additional external signal conditioning in many applications.

    The SPX2242 is available in explosion proof and ATEX / intrinsically safe versions. The SPX2242S intrinsically safe version is approved for II 1 G 100a Ex ia IIC, Zones 0 and 1. The SPX2242E explosion proof version is approved for Class I, Division I, Groups A, B, C and D. Optional thermocouple or RTD configurations are available to provide melt temperature measurement.

    Type Smart 4…20 mA pressure transmitter for hazardous locations
    Series Dynisco SPX2242
    Model SPX2242
    Application Pressure measurement in hazardous locations, plastics processing and industrial process plants
    Process connection 1/2-20 UNF thread for standard transducer mounting holes
    Output signal 4…20 mA, optionally with HART™ communication
    Input voltage, standard 16…36 VDC
    Input voltage, ATEX / intrinsically safe applications 16…30 VDC
    Pressure ranges 0…250 psi to 0…30,000 psi
    Accuracy ±0.25 % FSO; ±0.5 % FSO for ranges below 1,500 psi, including linearity, repeatability and hysteresis
    Repeatability ±0.1 % FSO
    Rangeability 3:1 turndown
    Over pressure 2 × FSO or 35,000 psi, whichever is less
    Zero balance adjustment range -40 % to +10 %; -80 % to +20 % for ranges <500 psi
    Gain span adjustment range ±2 % FSO maximum
    Load resistance 500 Ω at 26 VDC; 1000 Ω at 36 VDC
    Maximum diaphragm temperature 750 °F / 400 °C
    Zero shift due to diaphragm temperature change 15 psi / 100 °F typical or 27 psi / 100 °C
    Electronics operating temperature -20…185 °F / -29…85 °C
    Compensated electronics temperature range 0…150 °F / -18…65 °C
    Zero and span shift due to temperature change Each 0.01 % FS / °F max. or 0.02 % FS / °C max.
    Mounting torque 500 inch/lbs maximum
    Standard wetted parts DyMax™ coated 15-5 PH stainless steel
    Explosion proof version SPX2242E, Class I, Division I, Groups A, B, C and D; conduit fitting version
    ATEX / intrinsically safe version SPX2242S, II 1 G 100a Ex ia IIC, Zones 0 and 1
    ATEX / intrinsically safe connection options Conduit fitting or hermetically sealed 6-pin Bendix connector
    Optional temperature measurement Thermocouple or RTD configurations available for melt temperature measurement
    Configuration Configurable via handheld communicator
    Approvals and requirements Explosion proof, ATEX / intrinsically safe, meets PED and CE requirements
    Key features HART™ communication, 4…20 mA loop-powered output, 3:1 turndown, intrinsically safe and explosion proof versions, direct connection to DCS or PLC





    More documents




    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.