Dynisco SPX2242 Pressure Transmitter
The Dynisco SPX2242 is a smart 4…20 mA pressure transmitter for precise pressure measurement in hazardous locations. The all-welded construction is designed for demanding industrial applications and features a 1/2-20 UNF thread for installation in standard transducer mounting holes.
The loop-powered 4…20 mA output allows direct connection to DCS, PLC and other high-level control systems. Optional HART™ communication is available, enabling configuration via a handheld communicator. The integrated signal conditioning eliminates the need for additional external signal conditioning in many applications.
The SPX2242 is available in explosion proof and ATEX / intrinsically safe versions. The SPX2242S intrinsically safe version is approved for II 1 G 100a Ex ia IIC, Zones 0 and 1. The SPX2242E explosion proof version is approved for Class I, Division I, Groups A, B, C and D. Optional thermocouple or RTD configurations are available to provide melt temperature measurement.
| Type | Smart 4…20 mA pressure transmitter for hazardous locations |
|---|---|
| Series | Dynisco SPX2242 |
| Model | SPX2242 |
| Application | Pressure measurement in hazardous locations, plastics processing and industrial process plants |
| Process connection | 1/2-20 UNF thread for standard transducer mounting holes |
| Output signal | 4…20 mA, optionally with HART™ communication |
| Input voltage, standard | 16…36 VDC |
| Input voltage, ATEX / intrinsically safe applications | 16…30 VDC |
| Pressure ranges | 0…250 psi to 0…30,000 psi |
| Accuracy | ±0.25 % FSO; ±0.5 % FSO for ranges below 1,500 psi, including linearity, repeatability and hysteresis |
| Repeatability | ±0.1 % FSO |
| Rangeability | 3:1 turndown |
| Over pressure | 2 × FSO or 35,000 psi, whichever is less |
| Zero balance adjustment range | -40 % to +10 %; -80 % to +20 % for ranges <500 psi |
| Gain span adjustment range | ±2 % FSO maximum |
| Load resistance | 500 Ω at 26 VDC; 1000 Ω at 36 VDC |
| Maximum diaphragm temperature | 750 °F / 400 °C |
| Zero shift due to diaphragm temperature change | 15 psi / 100 °F typical or 27 psi / 100 °C |
| Electronics operating temperature | -20…185 °F / -29…85 °C |
| Compensated electronics temperature range | 0…150 °F / -18…65 °C |
| Zero and span shift due to temperature change | Each 0.01 % FS / °F max. or 0.02 % FS / °C max. |
| Mounting torque | 500 inch/lbs maximum |
| Standard wetted parts | DyMax™ coated 15-5 PH stainless steel |
| Explosion proof version | SPX2242E, Class I, Division I, Groups A, B, C and D; conduit fitting version |
| ATEX / intrinsically safe version | SPX2242S, II 1 G 100a Ex ia IIC, Zones 0 and 1 |
| ATEX / intrinsically safe connection options | Conduit fitting or hermetically sealed 6-pin Bendix connector |
| Optional temperature measurement | Thermocouple or RTD configurations available for melt temperature measurement |
| Configuration | Configurable via handheld communicator |
| Approvals and requirements | Explosion proof, ATEX / intrinsically safe, meets PED and CE requirements |
| Key features | HART™ communication, 4…20 mA loop-powered output, 3:1 turndown, intrinsically safe and explosion proof versions, direct connection to DCS or PLC |