Dynisco 1380 Programmable Digital Indicator with Strain Gauge Input
The Dynisco Model 1380 digital indicator is a compact, programmable process display for applications with strain gauge pressure sensors. In addition to two configurable alarms, the unit provides a selectable display for common pressure units and is therefore well suited for industrial pressure measurement and monitoring tasks.
Via the optional V or mA analog output, the user can retransmit the displayed process variable to other devices. The integrated calibration function, fast 100 ms measurement rate and open-wire monitoring make the Model 1380 a reliable display unit for use in plastics processing equipment and other industrial processes.
Separate LEDs on the front panel indicate alarms and pressure units. The instrument also supports peak value storage for minimum and maximum values as well as single-wire break monitoring. With the optional CPI interface and DynaLink configuration software, the 1380 can be conveniently configured from a computer.
| Type | Programmable digital indicator with strain gauge input |
|---|---|
| Series | Dynisco 1380 |
| Model | 1380 |
| Application | Process indication for pressure measurement with strain gauge sensors |
| Input | Strain gauge input, 350 ohm bridge |
| Display | 4 LED digits, 13.2 mm high; 2 red LEDs for alarm indication; 1 green LED for remote indication |
| Display range | Adjustable from 10 to 9,990 |
| Pressure units | Selectable display for common pressure units |
| Alarms | 2 programmable alarms / limit values |
| Alarm type | Closing and resting alarm for high or low limit monitoring; software configurable and permanently available |
| Alarm reset | Automatic or manual reset; start-up masking |
| Alarm outputs | 2 potential-free relay contacts |
| Output type | Normally open / normally closed |
| Contact rating | 0.6 A at 110 VDC resistive load; 0.5 A at 220 VDC resistive load; 0.3 A at 110 VDC inductive load |
| Analog output | Optional 0…20 mA, 4…20 mA max. 500 Ω; 0…5 VDC or 0…10 VDC |
| Zero balance | ±25 % full scale |
| Bridge excitation | 10 VDC ±7 % |
| Input sensitivity | 1.4…4 mV/V, automatic recognition |
| Calibration | Via internal shunt resistor, value 40…100 % |
| Accuracy | ±0.1 % full scale with shunt calibration |
| Processing time | 100 ms |
| Input monitoring | OPEN display in case of open wire |
| Single-wire break monitoring | Available |
| Peak value memory | Minimum / maximum memory |
| Operation / configuration | Configuration via CPI interface and DynaLink software possible |
| Power supply | 85…264 VAC, 50/60 Hz; 24 VDC optional |
| Weight | Approx. 250 g |
| Panel cut-out | 45 × 92 mm, +0.8 / 0 mm and +0.8 / 0 mm |
| Dimensions | 48 × 96 × 105 mm |
| Mounting | Two retaining clips on the rear side |
| Front protection | IP65 / NEMA 4 with suitable sealing |
| Environmental conditions | 0…55 °C; 85 % relative humidity, non-condensing |
| Key features | Strain gauge input, fast measurement rate, two programmable alarms, selectable pressure units, peak value memory, optional analog output, DynaLink configuration |

Datasheet