Dynisco Dyn-X-V Melt Pressure Sensors
The Dynisco Dyn-X-V Series includes melt pressure transmitters for general pressure measurement tasks in plastics processing. The sensors are designed for applications requiring simple installation, reliable measurements and good repeatability. With an industry-standard 0…10 VDC output signal, the transmitters can be used directly with PLCs, control systems and common readout instruments.
The Dyn-X-V pressure transmitters offer an accuracy of ±1.0 % FSO combined error, including linearity, repeatability and hysteresis. Zero and span are adjustable via potentiometers, allowing the sensor to be adapted to the respective process conditions. The standard wetted parts are made of DyMax® coated 15-5 PH stainless steel and support reliable pressure measurement in melt applications.
The series is available for pressure ranges from 0…500 psi to 0…10,000 psi. The sensors feature a four-arm bonded foil Wheatstone bridge strain gauge, internal 80 % shunt calibration and a 1/2-20 UNF process thread for installation in standard transducer mounting holes. Optional thermocouple or RTD configurations are available to provide melt temperature measurement in addition to pressure measurement.
| Type | Melt pressure transmitter with voltage output |
|---|---|
| Series | Dynisco Dyn-X-V Series |
| Application | General melt pressure measurement in plastics processing, extrusion and industrial processes |
| Output signal | 0…10 VDC |
| Input voltage | 16…36 VDC |
| Pressure ranges | 0…500 psi to 0…10,000 psi |
| Accuracy | ±1.0 % FSO combined error, including linearity, repeatability and hysteresis |
| Repeatability | ±0.2 % FSO |
| Configuration | Four-arm bonded foil Wheatstone bridge strain gauge |
| Load resistance | 2,000 Ω minimum |
| Over pressure | 2 × FSO or 35,000 psi, whichever is less |
| Zero balance adjustment range | ±15 % |
| Span adjustment range | ±15 % |
| Internal shunt calibration | 80 % FSO |
| Maximum diaphragm temperature | 750 °F / 400 °C |
| Zero shift due to diaphragm temperature change | 25 psi / 100 °F typical or 45 psi / 100 °C |
| Electronics operating temperature | -20…160 °F / -29…71 °C |
| Electronics zero shift due to temperature change | ±0.05 % FS / °F maximum or ±0.10 % FS / °C maximum |
| Span shift due to temperature change | ±0.02 % FS / °F maximum or ±0.04 % FS / °C maximum |
| Mounting torque | 500 inch/lbs maximum |
| Standard wetted parts | DyMax® coated 15-5 PH stainless steel |
| Process connection | 1/2-20 UNF thread |
| Optional temperature measurement | Optional thermocouple or RTD configurations available to provide melt temperature measurement |
| Key features | 0…10 VDC output, adjustable zero and span, DyMax® coated wetted parts, internal 80 % shunt calibration |

Datasheet