Dynisco TDT432 / TDT463 Melt Pressure Transmitters
The Dynisco TDT432 / TDT463 Series includes melt pressure transmitters with voltage outputs in 3- or 4-wire technology. The transmitters are based on the proven TDA Series with integrated thermocouple and convert the applied process pressure into a proportional voltage output signal. This ensures reliable signal transmission, even over longer distances.
The series combines proven strain gauge technology with a flexible capillary between stem and housing as well as a smooth, flush diaphragm. The integrated Type J thermocouple enables simultaneous temperature measurement directly at the media. In addition, the transducer includes an integrated electronic calibration device.
The TDT432 / TDT463 transmitters are suitable for media temperatures up to 400 °C and cover pressure ranges from 0…17 bar to 0…2000 bar. Depending on the required accuracy, the TDT432 model with 0.5 % accuracy and the TDT463 model with 1.0 % accuracy are available. The wetted parts are made of DyMax™ coated 15-5 PH stainless steel, material no. 1.4545.
| Type | Melt pressure transmitter with voltage outputs in 3- or 4-wire technology |
|---|---|
| Series | Dynisco TDT432 / TDT463 Series |
| Models | TDT432 and TDT463 |
| Measuring function | Melt pressure measurement with simultaneous temperature measurement at the media |
| Temperature measurement | Type J thermocouple |
| Pressure range | 0…17 bar to 0…2000 bar |
| Accuracy TDT432 | ±0.5 % F.S.; up to 50 bar ±1 % F.S. |
| Accuracy TDT463 | ±1 % F.S. |
| Repeatability TDT432 | ±0.1 % F.S.; up to 50 bar ±0.2 % F.S. |
| Repeatability TDT463 | ±0.2 % F.S. |
| Resolution | Infinite |
| Measuring system | 4-arm strain gauge |
| Internal calibration point | 80 % of full scale ±0.5 % |
| Zero adjustment range | ±5 % F.S. |
| Span adjustment range | ±5 % F.S. |
| Insulation resistance | 1000 MΩ at 50 VDC |
| Output signal 3-wire VDC | K: 0…5 VDC | M: 1…6 VDC | L: 0…10 VDC | N: 1…11 VDC |
| Output signal 4-wire VDC | G: 0…5 VDC | H: 0…10 VDC |
| Supply voltage | 15…32 VDC |
| Supply voltage 4-wire VDC | Dual ±10 to ±16 VDC or single 19…32 VDC |
| Load resistance | Depending on output >5 kΩ or >10 kΩ |
| Maximum overload | 2 × pressure range; for 1000 and 1400 bar range max. 1750 bar; for 2000 bar range max. 2450 bar |
| Burst pressure | 6 × pressure range, max. 3000 bar |
| Material in contact with media | 15-5 PH SST, material no. 1.4545, DyMax™ coated |
| Max. diaphragm temperature | 400 °C |
| Diaphragm zero shift due to temperature change | TDT432 < 0.2 bar / 10 °C; TDT463 < 0.4 bar / 10 °C |
| Max. housing temperature | 70 °C |
| Housing zero shift due to temperature change | ±0.2 % F.S. / 10 °C |
| Sensitivity shift due to temperature change | TDT432 ±0.1 % F.S. / 10 °C; up to 50 bar ±0.2 % F.S. / 10 °C; TDT463 ±0.4 % F.S. / 10 °C |
| Pressure connection | 1/2-20 UNF-2A or M18 × 1.5 |
| Stem length / flexible connection | Option 15/46: stem length 152 mm and flexible connection 457 mm between sensor stem and housing |
| Pressure range codes | 17: 0…17 bar | 35: 0…35 bar | 50: 0…50 bar | 1C: 0…100 bar | 2C: 0…200 bar | 3.5C: 0…350 bar | 5C: 0…500 bar | 7C: 0…700 bar | 1M: 0…1000 bar | 1.4M: 0…1400 bar | 2M: 0…2000 bar |
| Accessories | Indicators 1390 and 1391, Process Readout UPR700, Process Controller ATC770, Cleaning Tool Kit, Tool Kit |

Datasheet