Dynisco PT460XL Series
The Dynisco PT460XL Series includes robust pressure sensors for abrasive and corrosive melt pressure applications. The sensors are designed for applications requiring simple installation, reliable measurements and high repeatability. With an industry-standard 3.33 mV/V output signal, the PT460XL pressure sensors are designed to work with most common pressure indicators and readout instruments.
A key feature of the PT460XL Series is the Inconel diaphragm. It provides high resistance in demanding media and is especially suitable for processes involving abrasive or corrosive melts. The sensors are available for pressure ranges from 0…3,000 psi to 0…30,000 psi and offer an accuracy of ±1.0 % FSO combined error, including linearity, repeatability and hysteresis.
The PT460XL pressure sensors feature a four active arm bonded Wheatstone bridge strain gauge, internal 80 % shunt calibration and superior temperature stability. Optional thermocouple or RTD configurations are available to provide additional melt temperature measurement. Installation is carried out via a 1/2-20 UNF thread for standard transducer mounting holes.
| Type | Pressure sensor for abrasive and corrosive melt pressure applications |
|---|---|
| Series | Dynisco PT460XL Series |
| Application | Melt pressure measurement in abrasive and/or corrosive media |
| Output signal | 3.33 mV/V ±2.0 % |
| Pressure ranges | 0…3,000 psi to 0…30,000 psi |
| Accuracy | ±1.0 % FSO combined error, including linearity, repeatability and hysteresis |
| Repeatability | ±0.2 % FSO |
| Maximum pressure | 2 × full range or 35,000 psi, whichever is less |
| Configuration | Four active arm bonded Wheatstone bridge strain gauge |
| Bridge resistance input | 345 Ω minimum |
| Bridge resistance output | 350 Ω ±10 % |
| Zero balance | ±10 % full scale |
| Input voltage | 10 VDC recommended, 12 VDC maximum |
| Internal shunt calibration | 80 % FSO ±1.0 % |
| Insulation resistance | 1,000 MΩ at 50 VDC |
| Maximum diaphragm temperature | 750 °F / 400 °C |
| Zero shift due to diaphragm temperature change | <20 psi / 100 °F maximum or <36 psi / 100 °C |
| Maximum electronics housing temperature | 250 °F / 121 °C |
| Zero shift due to electronics housing temperature change | ±0.05 % full scale / °F maximum or ±0.10 % full scale / °C |
| Sensitivity shift due to temperature change | ±0.02 % full scale / °F maximum or ±0.04 % full scale / °C |
| Mounting torque | 500 inch/lbs maximum |
| Standard wetted parts | Inconel 718 |
| Diaphragm material | Inconel diaphragm |
| Process connection | 1/2-20 UNF thread |
| Optional temperature measurement | Optional thermocouple or RTD configurations available to provide melt temperature measurement |
| Key features | Superior temperature stability, patented sensing element, internal 80 % shunt calibration, suitable for abrasive and corrosive applications |

Datasheet