Conto-72-Pt – Static Meter submetering applications for low, medium voltege networks (with limites indicated for CT and VT ratio) 72x72mm


  • Static energy meter for submetering applications in 72 × 72 mm format
  • Measures active energy, reactive energy, power demand and maximum power demand
  • Suitable for single-phase and three-phase networks
  • Direct connection possible for 400…415 V, 230…240 V and 100…115 V
  • Isolated current input for external current transformers with 1 A or 5 A secondary current
  • Programmable external VT and CT ratio
  • Programmable pulse output
  • RS485 communication as well as optional Ethernet and PROFIBUS interfaces
Datasheet
User Manual

Conto 72-Pt

Static meter for submetering applications, 72 × 72 mm

Type Static meter for submetering applications
Dimensions 72 × 72 mm
Measured values Total and partial active energy, total and partial reactive energy, power demand and maximum power demand
Network Single-phase and three-phase networks
Direct connection, three-phase 400…415 V
Direct connection, single-phase 230…240 V
Alternative direct connection Single-phase and three-phase 100…115 V
Current transformer input Isolated current input, connection via external current transformers with 1 A or 5 A secondary current, same reference
Transformer ratio Programmable external VT and CT ratio
Pulse output Programmable pulse output
Interface RS485 communication
External interfaces Ethernet communication NT685, PROFIBUS communication NT592




Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    Conto-72-Pt – Static Meter submetering applications for low, medium voltege networks (with limites indicated for CT and VT ratio) 72x72mm

    • Static energy meter for submetering applications in 72 × 72 mm format
    • Measures active energy, reactive energy, power demand and maximum power demand
    • Suitable for single-phase and three-phase networks
    • Direct connection possible for 400…415 V, 230…240 V and 100…115 V
    • Isolated current input for external current transformers with 1 A or 5 A secondary current
    • Programmable external VT and CT ratio
    • Programmable pulse output
    • RS485 communication as well as optional Ethernet and PROFIBUS interfaces
    Datasheet
    User Manual

    Conto 72-Pt

    Static meter for submetering applications, 72 × 72 mm

    Type Static meter for submetering applications
    Dimensions 72 × 72 mm
    Measured values Total and partial active energy, total and partial reactive energy, power demand and maximum power demand
    Network Single-phase and three-phase networks
    Direct connection, three-phase 400…415 V
    Direct connection, single-phase 230…240 V
    Alternative direct connection Single-phase and three-phase 100…115 V
    Current transformer input Isolated current input, connection via external current transformers with 1 A or 5 A secondary current, same reference
    Transformer ratio Programmable external VT and CT ratio
    Pulse output Programmable pulse output
    Interface RS485 communication
    External interfaces Ethernet communication NT685, PROFIBUS communication NT592




    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.