Housing 48 x 24 mm
Display 4-digit 10 mm digit height Colour: red, green, orange or blue display
Range displayed -1999 to 9999
Operation front panel keyboard protection class IP65
Input Resistance 0…1 kOhm span 0… 1.1 kOhm 0…10 kOhm span 0…11 kOhm 0…100 kOhm span 0…110 kOhm 0…1000 kOhm span 0…1100 kOhm
Analogue Output
Switch point
Interface
Power supply 24 VDC +/-10% galvanic isolated Other voltage supplies on demand!
Sensor supply
Software properties
  • Min/Max-value recording
  • 10 adjustable supporting point
  • display flashing at threshold exceedance/undercut
  • navigation keys for polling of min/max-values or for threshold corrections during operation
  • Tara-function
  • programming interlock via access code
Datasheet
User Manual

 

Housing 48 x 24 mm
Display 5-digit 10 mm digit height Colour: red, green, orange or blue display
Range displayed -19999 to 99999
Operation front panel keyboard protection class IP65
Input Resistance 0…1 kOhm span 0… 1.1 kOhm 0…10kOhm span 0…11 kOhm Digital input: <2.4V OFF, >10V ON, max. 30 VDC
Analogue Output 0/4-20 mA / 0-10 VDC / 16 Bit Alternatively digital input
Switch point 2 PhotoMos outputs (NOC) 30 VDC/AC, 0.4 A
Interface
Power supply 24 VDC galvanic isolated 100-240 VAC 50/60 Hz / DC +/- 10%
Sensor supply
Software properties
  • min/max-memory with adjustable permanent display
  • 30 additional adjustable supporting points
  • display flashing at threshold value exceedance/undercut
  • navigation keys for the triggering of Hold, Tara, display change, setpoint setting, alarm actuator
  • flexible alarm system with adjustable delay times
  • volume metering (Totaliser)
  • mathematical functions like reciprocal value, square root, squaring and rounding
  • constant setting/setpoint setting
  • sliding averaging
  • brightness control via parameter or front keys
  • programming interlock via access code
Datasheet
User Manual

Housing 72 x 36 mm
Display 4-digit 14 mm digit height Colour: red, green, orange or blue display
Range displayed -1999 to 9999
Operation front panel keyboard protection class IP65
Input Resistance 0…1  kOhm span 0… 1.1 kOhm 0…10 kOhm span 0…11 kOhm 0…100 kOhm span 0…110 kOhm 0…1000 kOhm span 0…1100 kOhm
Analogue Output
Switch point 2 relay outputs 250 V / 5 AAC, 30 V / 5 ADC
Interface
Power supply 230 VAC 24 VDC +/-10% galvanic isolated Other voltage supplies on demand!
Sensor supply
Software properties
  • Min/Max-value recording
  • 10 adjustable supporting point
  • display flashing at threshold exceedance/undercut
  • navigation keys for polling of min/max-values or for threshold corrections during operation
  • Tara-function
  • programming interlock via access code
Datasheet
User Manual

Housing 96 x 24 mm
Display 4-digit 14 mm digit height Colour: red, green, orange or blue display
Range displayed -1999 to 9999
Operation front panel keyboard protection class IP65
Input Resistance 0…1 kOhm span 0… 1.1 kOhm 0…10 kOhm span 0…11 kOhm 0…100 kOhm span 0…110 kOhm 0…1000 kOhm span 0…1100 kOhm
Analogue Output
Switch point
Interface
Power supply 230 VAC 24 VDC +/-10% galvanic isolated Other voltage supplies on demand!
Sensor supply
Software properties
  • Min/Max-value recording
  • 10 adjustable supporting point
  • display flashing at threshold exceedance/undercut
  • navigation keys for polling of min/max-values or for threshold corrections during operation
  • Tara-function
  • programming interlock via access code
Datasheet
User Manual

Housing 96 x 24 mm
Display 5-digit 14 mm digit height Colour: red, green, orange or blue display
Range displayed -19999 to 99999
Operation front panel keyboard protection class IP65
Input Resistance 0…1 kOhm span 0… 1.1 kOhm 0…10 kOhm span 0…11 kOhm 0…100 kOhm span 0…110 kOhm
Analogue Output 0/4-20 mA / 0-10 VDC / 16 Bit Alternatively interface RS232/RS485
Switch point 2 relays (change-over contact) 250 VAC / 2 AAC ; 30 VDC / 2 ADC
Interface RS232 or RS485 galvanic isolated Alternatively analog output
Power supply 10-40 VDC / 18-30 VAC 50/60Hz 100-240 VAC 50/60 Hz / DC +/- 10%
Sensor supply
Software properties
  • min/max-memory with adjustable permanent display
  • 30 additional adjustable supporting points
  • display flashing at threshold value exceedance/undercut
  • navigation keys for the triggering of Hold, Tara, display change, setpoint setting, alarm actuator
  • flexible alarm system with adjustable delay times
  • volume metering (Totaliser)
  • mathematical functions like reciprocal value, square root, squaring and rounding
  • constant setting/setpoint setting
  • sliding averaging
  • brightness control via parameter or front keys
  • programming interlock via access code
Datasheet
User Manual

 

Housing 96 x 48 mm
Display 5-digit 14 mm digit height Colour: red, green, orange or blue display
Range displayed -19999 to 99999
Operation front panel keyboard protection class IP65
Input Resistance 0…1 kOhm span 0… 1.1 kOhm 0…10 kOhm span 0…11 kOhm 0…100 kOhm span 0…110 kOhm Digital input: <2.4V OFF, >10V ON, max. 30 VDC
Analogue Output 0/4-20 mA / 0-10 VDC / 16 Bit Alternatively digital input
Switch point 2 relays (change-over contact) 250 V / 5 AAC, 30 V / 5 ADC
Interface
Power supply 230 VAC 10-30 VDC galvanic isolated Other voltage supplies on demand!
Sensor supply
Software properties
  • min/max-memory with adjustable permanent display
  • 30 additional adjustable supporting points
  • display flashing at threshold value exceedance/undercut
  • zero-key for triggering of Hold, Tara, display change, setpoint setting, alarm actuator
  • flexible alarm system with adjustable delay times
  • volume metering (Totalisator)
  • mathematical functions like reciprocal value, square root, squaring and rounding
  • constant setting/setpoint setting
  • sliding averaging
  • brightness control via parameter or front keys
  • programming interlock via access code
Datasheet
User Manual

Housing 96 x 48 mm
Display 5-digit 14 mm digit height Colour: red, green, orange or blue display
Range displayed -19999 to 99999
Operation front panel keyboard protection class IP65
Input Resistance 0…1 kOhm span 0… 1.1 kOhm 0…10 kOhm span 0…11 kOhm 0…100 kOhm span 0…110 kOhm Digital input: <2.4V OFF, >10V ON, max. 30 VDC
Analogue Output 2 analog outputs 0/4-20 mA / 0-10 VDC / 16 Bit
Switch point 2 or 4 relays (change-over contacts) 250 V / 5 AAC, 30 V / 5 ADC or 8 PhotoMos outputs (NOC) 30 V / 0.4 A AC/DC
Interface RS232 or RS485 galvanic isolated Alternatively to analog output 2
Power supply 100-240 VAC 50/60 Hz / DC +/- 10% 10-40 VDC / 18-30 VAC 50/60Hz
Sensor supply
Software properties
  • min/max-memory with adjustable permanent display
  • 30 additional adjustable supporting points
  • display flashing at threshold value exceedance/undercut
  • zero-key for the triggering of Hold, Tara, display change, setpoint setting, alarm actuator
  • flexible alarm system with adjustable delay times
  • volume metering (Totaliser)
  • mathematical functions like reciprocal value, square root, squaring and rounding
  • constant setting/setpoint setting
  • sliding averaging
  • brightness control via parameter or front keys
  • programming interlock via access code
Datasheet
User Manual


Digital Panel Meters for Resistance Measurement

Digital panel meters with resistance input measure the electrical resistance of a connected resistor, transducer or sensor, and display the value on a multi-digit LED display. They are designed for panel mounting in control cabinets, generally feature front protection up to IP65, and allow freely scalable readout. This enables direct reading of resistance values or conversion to a desired unit (e.g. temperature, position, etc.), depending on the application and sensor type used.

Questions & Answers

What is the purpose of resistance panel meters in control cabinets?

They are used to directly measure resistance — for example of sensors, resistive elements, measuring bridges or circuit components. This allows checking component integrity or evaluating sensors based on resistance output.

Which resistance ranges can typically be measured?

Depending on the device, low to moderate resistance values are measurable — typically ranging from a few ohms up to several kiloohms. The exact measurement range must be verified for the chosen device.

How is the resistance displayed?

The measured resistance is shown directly in ohms (Ω). Through configurable scaling, the meter can also display converted or derived quantities if a sensor maps resistance to a physical parameter.

Is scaling to other physical units possible?

Yes — if a sensor or transducer translates resistance into a physical magnitude (e.g. temperature, position, strain), the meter can be scaled so that the display shows the corresponding physical unit instead of ohms.

What display characteristics are common?

Multi-digit LED displays are used, often with digit heights around 10 mm or 14 mm. Available LED colors typically include red, green or orange to visually distinguish measurement points.

Are analog or relay outputs available?

Depending on the model, analog outputs such as 0/4–20 mA or 0–10 V may be provided to forward the measured resistance or scaled value to controllers or data acquisition systems. Relay outputs are less common but may be available in certain variants.

What supply voltages are typically required?

Common supply options are 24 VDC (galvanically isolated) or universal supplies such as 100–240 VAC, depending on the device version.

How is configuration carried out?

Configuration is done via a front keypad. Adjustable parameters typically include measurement range, scaling, display unit, decimal point and — if available — analog/relay output behavior. No need to open the cabinet.

When is using a resistance meter appropriate?

Such meters are appropriate when direct resistance measurement is required — for verifying sensors, resistive components or measuring cards — or when a resistance-based sensor is used and its output should be displayed or processed further.

What panel cut-out sizes are typically available?

These devices are designed for standard panel cutouts — depending on display size and features typically 48×24 mm, 72×36 mm or 96×48 mm.

Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.