- Multi-function capabilities: electrical, frequency, temperature and pressure
- Optional HART and Foundation Fieldbus communicators
- ATEX, IECEx and ETL approved for hazardous area use
- Modular re-rangeable and expandable concept
- Individual components can be used as stand-alone instruments
- Allows significant inventory reductions
- Simplifies training and improves operator safety
- Reduces cost of ownership
- Provided with one free 4Sight2 Lite calibration software license
![]() |
Measuring counts | Â |
TRMS | Â |
AC/DC voltage | 1000V anche AC+DC |
AC/DC current | 1A anche AC+DC |
Resistance and buzzer continuity | Â |
Diode test | Â |
Frequency | Â |
DC 4-20mA current measurement | Â |
DC 0-10V voltage measurement | Â |
DC 4-20mA current generation | Â |
Measurement of output current of transducers | Â |
Simulation of an external transducer | Â |
Loop supply with minimum voltage 24V | Â |
Generation of selectable ramp | Â |
Load of 250Ω for testing HART transducers |  |
Backlit LCD display | Â |
Autorange | Â |
Auto Power OFF | Â |
Data HOLD | Â |
MIN/MAX function | Â |
AVG function | Â |
Relative measurement | Â |
Protection category | CAT IV |
Weight in grams (batteries included) | Â |
Size (LxWxH) (mm) |
![]() |
Measuring counts | Â |
TRMS | Â |
AC/DC voltage | MAX 10VDC |
AC/DC current | MAX 24mADC |
DC 4-20mA current measurement | Â |
DC 0-10V voltage measurement | Â |
DC 4-20mA current generation | Â |
DC 0-10V voltage generation | Â |
Measurement of output current of transducers | Â |
Simulation of an external transducer | Â |
Loop supply with minimum voltage 24V | Â |
Generation of selectable ramp | Â |
Backlit LCD display | Â |
Auto power off | Â |
Protection category | Â |
Weight in grams (batteries included) | Â |
Size (LxWxH) (mm) |
![]() |
- Current Calibrator 0/4 - 22mA, Source/Sink
- Voltage Calibrator 0-14V
- mV Ranges 0-28mV and 0-560 mV
- DIN Thermocouples J, K, N, R, S, T, B, E
- Multimeter ±2V to ±200V DC and ±100mA
- Simultaneous Calibration and Measurement
- Steps, Ramps, direct entry
- Built-in rechargeable Battery
![]() |
- Current Output 0-22mA, Source/Sink
- Voltage Output 0-25V
- mV Outputs 0-27mV and 0-540 mV
- DIN Thermocouples J, K, N, R, S, T, B, E
- RTD Simulator -200 ⊠850ÂșC
- Resistance Range up to 3kOhm
- Multimeter ±2V to ±200V DC and ±100mA
- Measurements of fast Transients
- Datalogger Function (Option)
- 8 Tables with each 50 free Output Points
![]() |
- Measuring and  Sourcing loop current, mV, and V
- Measuring and sourcing simultaneously
- Loop integrity check capability
- 24V loop supply with simultaneous current measurement
- Three year warranty
- ISO 17025-accredited calibration w/data included
![]() |
- Accuracy to 0.01% of reading
- Measure, source, or simulate loop current
- Measure DC volts
- Simultaneously mA and % span display
- Switch functionality
- Selectable ramp and step functions
- HART 250⊠resistor in series with 24V loop
- ISO 17025-accredited calibration w/data included
![]() |
![]() |
- Sourcing, simulating and measuring, temperature and electrical signals
- Smartphone-like menu and interface make the operation simpler and easier
- The internal cold junction compensation sensor can be re-calibrated  at ice point by users
- Ultra-compact, 3.9â x 7.6â x 2.0â, and 1.6 lb (0.7 kg)
- ISO 17025-accredited calibration w/data included
![]() |
- Sourcing, simulating and measuring pressure, temperature and electrical signals
- Smartphone-like menu and interface make the operation simpler and easier
- The internal cold junction compensation sensor can be re-calibrated at ice point by users
- Ultra-compact, 3.9â x 7.6â x 2.0â, and 1.6 lb (0.7 kg)
- ISO 17025-accredited calibration w/data included
![]() |
âąÂ Sourcing, simulating and measuring pressure, temperature and electrical signals
âąÂ Built-in Barometer
âąÂ Intrinsically safe models available (Ex)
âąÂ Large Smartphone like touchscreen user experience
âąÂ USB Type-C and Bluetooth communications
âąÂ IP67 Rated
âąÂ High Voltage Measurement Capability (±300V AC)
âąÂ True RMS Voltage Meter Capability
âąÂ Dual channel pressure module ports
âąÂ High Static Differential Pressure Measurement 0.002% FS
âąÂ ISO 17025-accredited calibration w/data included
![]() |