  • 5 voltage inputs & 4 current inputs
  • All-terrain shockproof casing resistant to UV light and high temperatures
  • Ideal for mounting on electricity poles
  • Self-powered by its voltage inputs up to 1, V
  • Continuous recording at 2 ms intervals
  • Measurements in compliance with IEEE 1459
Datasheet

The CA 6116N is an ALL-IN-ONE instrument for testing electrical installations in compliance with the national and international standards (IEC 60364-6, NF C 15-100, VDE 100, FD C 16-600, etc). It combines design, ergonomics, simplicity, performance, rapidity and accuracy. Suitable for all neutral systems (TT, TN, IT), it is ideal for all sectors: industry, tertiary and residential.

Datasheet

The CA 6117 is an ALL-IN-ONE instrument for testing electrical installations in compliance with the national and international standards (IEC 60364-6, NF C 15-100, VDE 100, FD C 16-600, etc). It combines design, ergonomics, simplicity, performance, rapidity and accuracy. Suitable for all neutral systems (TT, TN, IT), it is ideal for all sectors: industry, tertiary and residential.

Datasheet

AUTO test (Non-trip ground resistance, RCD, Insulation) in sequence
Insulation with test voltages 100, 250, 500, 1000VDC
Measurement of dielectric absorption ratio D.A.R.
Measurement of polarization index P.I.
Continuity of protective conductors with 200mA
Tripping time of type A, AC General and Selective RCDs
Non-trip earth resistance
Loop/Line impedance, Phase-Phase, Phase-Neutral, Phase-PE
Loop/Line impedance Phase-Phase, Phase-Neutral, Phase-PE with high resolution (0.1mΩ) With optional accessory IMP57
Contact voltage
Phase sequence
Help on line on the display
Internal memory for measured data saving
Optical/USB serial port for PC connection
Protection rating
Power supply
Protection category CAT IV 300V
Weight in grams (batteries included) 1200
Size (LxWxH) (mm) 222x162x57
Datasheet
User Manual

AUTO test (Non-trip ground resistance, RCD, Insulation) in sequence
Insulation with voltage 50, 100, 250, 500, 1000VDC
Measurement of polarization index P.I.
Tripping time and current of F-type RCDs
Measurement of dielectric absorption ratio D.A.R.
Continuity of protective circuit with 200mA
Tripping time and current of RCDs type A, AC Standard, Selective B type up to 300mA
Non-trip earth resistance
Loop/Line impedance Phase-Phase, Phase-Neutral, Phase-PE with high resolution (0.1mΩ) With optional accessory IMP57
Loop/Line impedance, Phase-Phase, Phase-Neutral, Phase-PE
Percentage voltage drop on the line
Contact voltage
Phase sequence
Help on line on the display
Internal memory for measured data saving
Optical/USB serial port for PC connection
Protection rating
Power supply
Protection category CAT IV 300V
Weight in grams (batteries included) 1200
Size (LxWx H) (mm) 222x162x57
Datasheet
User Manual

  • All electrical safety measurements as required by the international safety standards
  • AUTOMATIC test (no-trip ground resistance, RCD tripping time, insulation resistance) in a sequence
  • Continuity of protective conductors with 200mA
  • Insulation resistance up to 1000V, with dielectric absorption ratio D.A.R. and polarization index P.I.
  • Polarity test
  • Type A, AC, B General and Selective RCD tripping time and current
  • Line/Fault impedance, Phase-Phase, Phase-Neutral, Phase-PE (also at high resolution with optional accessory IMP57)
  • Coordination of MCBs and fuses
  • Global earth resistance
  • Phase sequence and conformity measurement
  • Measurement of leakage current
  • Measurement of electrical parameters in single-phase installations (V, A, W, VAR, VA, PF)
  • Measurement of environmental parameters through external probes (HT52/05 and HT53/05)
  • Internal memory and PC connection
  • Wi-Fi connection to Android and iOS smartphones and tablets
Datasheet
User Manual

Combined device for measuring insulation and continuity of protective and equipotential conductors with 200mA
M70 is a mobile device dedicated to measuring Insulation resistance with test voltage up to 1000VDC and Continuity of protective and equipotential conductors with current of 200mA in private and industrial electric installations.
Thanks to the LOCK function, insulation measurement can be carried out in a continuous manner over time, thus testing the insulation of the target with a duration test. It carries out measurement with a timer, programmable from 2 to 60s.

Datasheet

Combined device for insulation measurement, continuity of protective conductors and multimeter function TRMS

M72 is mainly dedicated to measuring Insulation resistance and Continuity of protective and equipotential conductors with 200mA in electric installations, typically private.

Further to these measurements, M72 has many additional functions such as measurement of phase sequence with 1 terminal, measurement of leakage currents with optional clamp transducer and a powerful multimeter function for measuring voltage and current in true root mean square value (TRMS).

Datasheet

M73 has been developed for operators who mainly work on private installations. M73 is very easy to use, it is very small in size and it carries out all necessary tests to establish COMPLIANCE (and hence ensure SAFETY) of an electric system.
By always using it before starting working on an already existing system (which the operator therefore does not know well) and at the end of the job, this device will guarantee the necessary safety to both operators and users of the electric systems! Thanks to its small size, this device offers many operating opportunities. M73 is also used to test the safety of electric system; it s therefore capable of measuring non-trip earth resistance, carrying out tests on RCDs type A and AC and measuring Insulation and Continuity. At the end of the test, the device shows all results with the indication of compliance or non-compliance with the standards with simple symbols di OK or NOT OK.

Datasheet

Device for safety tests according to IEC/EN61557-1 with TRMS multimeter functions
M74 measures Overall earth resistance, tripping time of RCDs type AC, Insulation and Continuity of earth and equipotential conductors according to the laws in force in private electric installations.
In order to make it versatile and fully functional for any kind of end user, the device has been provided with the innovative AUTO: function: by selecting this function and only setting the value of RCD current, M74, connected to a power outlet, carries out tests of overall earth resistance, RCD tests and insulation tests in a sequence. At the end of the test, the device shows all results with the indication of compliance or non-compliance with the standards with simple symbols OK or NOT OK.
M74 has many additional functions such as measurement of phase sequence with 1 terminal, measurement of leakage currents with optional clamp transducer and a powerful multimeter function for measuring voltage and current’s true root mean square value TRMS.

Datasheet