- 41 pressure ranges from ±25 mbar to 1,400 bar (±10 inH₂O to 20,000 psi / 2.5 kPa to 140 MPa)
- Total 1-year uncertainty up to 0.025% of full scale (FS) across the temperature range of -10 °C to +50 °C
- Integrated calibration record with countdown display for next due date
- Rugged, handheld design with backlit, high-contrast display
- Functions for leak test, tare, maximum/minimum display and filtering
- Version for hazardous areas (intrinsically safe) available
- Optional external plug-and-play sensors: pressure sensor (PM700E) and RTD temperature probe (RTD-PROBE)
- Compatible with our pneumatic and hydraulic hand pumps
- Compatible with 4Sight2 for automated calibration processes
Datasheet |
User Manual |
- Accuracy: 0.1 % FS (incl. calibration certificate)
- Data logger with high measuring rate and large memory
- Chart preview directly on the instrument
Datasheet |
User Manual |
- Intrinsically safe indicator with interchangeable pressure sensors model CPT62I0 (plug-and-play)
- Measuring ranges 0 ... 1,000 bar [0 ... 14,500 psi]
- Type of pressure: Positive and negative overpressure, absolute pressure and differential pressure
- Accuracy: 0.2 %, optionally 0.1 % (incl. calibration certificate)
- Data logger for recording measured values
Datasheet |
User Manual |
Hold, Zero, 7 selectable units, smoothing, lock, Max/Min.IP67
This unit features a 0 - 25 millibar operating range and a 350 millibar over range. It is also IP67 rated.
Datasheet
|
User Manual
|
- Robust and waterproof digital indicator with interchangeable pressure sensors (plug-and-play)
- Measuring ranges from 0 ... 25 mbar to 0 ... 1,000 bar (0 ... 0.4 psi to 0 ... 14,500 psi)
- Pressure type: positive and negative gauge pressure, absolute pressure and differential pressure
- Accuracy: 0.2 %, optional 0.1 % (incl. calibration certificate)
- Software and complete service cases (incl. pumps) available
Datasheet |
User Manual |
A wide variety of reference pressure sensors, offering
various measuring ranges of up to 6,000 bar (75,000 psi),
are available to the operator, always ensuring a solution
matched to the application.
Datasheet
|
User Manual
|
- Manual pressure generation of -0.85 … +25 bar [12.3 ... +360 psi]
- Accuracy: 0.025 % FS (incl. calibration certificate)
- Generation/measurement of 0 ... 24 mA and voltage supply DC 24 V
- Data logger with high measuring rate and large memory
- Intrinsically safe version
The Additel 760 series Automatic Handheld Pressure Calibrator takes portable pressure calibration to new levels. Weighing less than 4 lbs (1.8 kg), the ADT760’s innovative design contains a built-in pump, precision pressure sensor, internal controller and a large touch-screen color display.
Datasheet |
User Manual |
- max. Pressure range: -0,86 bar up to 2,5 bar
- Accuracy: 0,02% v.E.
- Stability: 0,005% v.E.
Datasheet |
User Manual |
- max. Pressure range: ±75 mbar
- Accuracy: 0,05% v.E.
- Stability: 0,005% v.E.
Datasheet |
User Manual |
- Pressure ranges (internal/external): 0–70 mbar up to 0–700 bar Gauge, absolute, and differential pressure
- Also available in intrinsically safe version, EEx ia II C T4
- High accuracy: 0.1% of full scale
- Lightweight, robust ABS housing with stand
- Ergonomic design, battery powered, 300 h operating time
- Leak test, max/min monitoring, filter function
- Connection kits with hand pumps
Datasheet |
- Digital indicator with interchangeable pressure sensors (plug-and-play)
- Measuring ranges from 0 ... 25 mbar to 0 ... 1,000 bar (0 ... 0.4 psi to 0 ... 14,500 psi)
- Type of pressure: positive and negative overpressure, absolute pressure and differential pressure
- Accuracy: 0.2 %, optional 0.1 % (incl. calibration certificate)
- Software and complete service cases (incl. pumps) available
Datasheet
|
User Manual
|
- Pressure ranges from 130mbar to 10bar
- 130mbar available as Screw or Push Fit
- Positive and vacuum pressure measurement
- Auto ranging displays – for precise readings
- Selectable auto switch off – Increases battery life
- IP67 BSI Cert 229/000132 – Dust and waterproof protection
- Selectable pressure units
Datasheet
|
Hold, Zero, 7 selectable units, smoothing, lock, Max/Min.IP67 This unit features a 0 - 130 millibar operating range and a 750 millibar over range. It is also IP67 rated.
Datasheet |
User Manual |
Hold, Zero, 7 selectable units, smoothing, lock, Max/Min.IP67
This unit features a 0-2 bar operating range and a 4 bar over range. It is also IP67 rated.
Datasheet
|
User Manual
|
Hold, Zero, 7 selectable units, smoothing, lock, Max/Min.IP67
This unit features a 0-7 bar operating range and a 10 bar over range. It is also IP67 rated.
Datasheet
|
User Manual
|
Hold, Zero, 7 selectable units, smoothing, lock, Max/Min.IP67
Featuring 0-10 bar operating range and a 21bar over range. This product is also IP67 rated.
Datasheet
|
User Manual
|
- 0-1 bar operating range
- 2 bar over range
- -10°C to 50°C
- Backlit function
- Zeroing function
- Hold function
- Range lock function
- Max/Min
- Selectable units of pressure
- Port size 4mm
Datasheet |
User Manual |
-
High-precision absolute pressure measurement with an accuracy of ±3 hPa
-
Suitable for barometric altitude measurements
-
Calculates the barometric air pressure
-
8 pressure units available
Small, handy and practical: the testo 511 absolute pressure meter measures absolute pressure and is also suitable for measuring the barometric altitude between two points.
Datasheet
|
User Manual
|
- Probes available as an option mean you can measure air humidity, temperature, absolute pressure and dew point in compressed air
- Two plug-in probes and 3 radio probes can be attached
- Calculates dew point and dew point distance
- Display of min., max. and mean values
The testo 635-1 temperature and humidity measuring instrument enables you to measure the temperature, air humidity and dew point – in compressed air as well. State-of-the-art technology and a large selection of probes, which are available as an option, enable this wide variety of measuring possibilities.
Datasheet |
User Manual |
- Optionally available sensors for moisture, temperature, pressure dew point and absolute pressure measurements
- 2 plug-in sensors and 3 wireless sensors can be connected
- Super-size memory for up to 10 000 readings
- USB cable and PC software for archiving and logging measuring data included
The testo 635-2 temperature and moisture meter allows you to carry out temperature and moisture measurements on a variety of different materials, surfaces and environments. This is made possible due to leading-edge technology and a wide selection of optionally available sensors.
Datasheet |
User Manual |
- 0-130 mbar measurement
- 0.01 resolution up to 19.99 mbar, then auto switches to 0.1 resolution
- Differential Input - 8mm tube connectors
- Water Resistant (IP67 rated)
- Rugged case with protective rubber boot
- Magnetic attachment or tilt stand
- Push button Zero and Hold features
- Backlit Digital Display
- Auto Power Off after 12 minutes
- Measurement unit options (Selectable on the PM80)
Datasheet |
User Manual |
Handheld Pressure Gauges – mobile, precise, versatile
Handheld pressure gauges are the flexible choice for service, maintenance, commissioning, and quality assurance. From quick on-site checks to high-resolution reference measurements, they offer functions such as Min/Max/Peak, tare/zero, data logging, leak testing, and—depending on the model—differential or absolute pressure.
ICS Schneider Messtechnik supplies rugged instruments with protection up to IP65/IP67, a wide range of spans (vacuum to high pressure), media-compatible connection kits, calibration certificates (ISO/DAkkS), and optional IIoT connectivity via data export or edge gateway.
FAQ on Handheld Pressure Gauges
Answers on measuring types, selection, accuracy, calibration accessories, leak testing, logging, power supply, and safety.
What measuring types do handhelds support?
| Type | Typical application | Notes |
|---|---|---|
| Gauge pressure (g) | Hydraulics/pneumatics | Referenced to ambient |
| Absolute pressure (a) | Vacuum/barometry | Independent of weather |
| Differential pressure (Δp) | Filters/flow | ± ranges, zeroing required |
How do I select the right measuring range?
Rule of thumb: working pressure × 1.3–2.0. With pulsation/spikes, select a higher range or add damping (restrictor/snubber). Use dedicated ranges for vacuum/absolute.
What accuracies are typical?
Depending on model ±0.05…0.25% of span (often specified as total error band over the rated temperature range). For test tasks choose instruments with factory or DAkkS certificate.
Which connections do I need for field work?
| Connection | Standard | Use |
|---|---|---|
| G 1/4 / G 1/2 | ISO 228 | General industry |
| ¼" / ½" NPT | ASME | US installations |
| Minimess®/test port | — | Quick checks/hydraulics |
Are hose and adapter kits available?
Yes—complete service kits with pressure-rated hoses, quick couplings (e.g., Minimess®), and thread adapters simplify use and reduce leakage risks.
Can I perform leak tests?
Many instruments offer pressure hold/leak-rate modes (Δp/Δt). In combination with a test pump or reference source you can generate test reports.
What calibration accessories make sense?
| Accessory | Benefit | Note |
|---|---|---|
| Hand test pump (air/oil) | Generates reference pressure | Prefer fine volume adjuster |
| Pressure regulator | Stable supply | For high-pressure sources |
| Fine restrictor/snubber | Damps pulsation | Protects the sensor |
How are measurements documented?
Depending on the device via internal data logger, USB/Bluetooth export (CSV/JSON) or app/software. For IIoT: export → edge gateway → MQTT/HTTPS into SCADA/cloud.
Which units are available?
Switchable (e.g., bar, psi, kPa, MPa, mbar). Keep units consistent in reports. Useful factors:
| From | To | Factor |
|---|---|---|
| 1 bar | Pa | 100,000 |
| 1 bar | psi | 14.5038 |
| 1 psi | bar | 0.06895 |
How long do the batteries last?
Typically 6–36 months depending on display brightness, sampling rate, and logging. Auto-off and adjustable sampling extend runtime; use a power supply for long tests.
What protection ratings and robustness are available?
Commonly IP54–IP67, shock-resistant housings; consider protective boots and media resistance of fittings. For outdoor/harsh use, prefer IP67.
What ambient/medium temperatures are allowed?
Ambient typically −10…+50 °C (model-dependent). Connect hot media via capillary/cooling section; avoid condensation.
How do I prevent sensor damage?
- Do not exceed the measuring range (overpressure protection)
- Use restrictor/snubber for pulsation
- Prevent medium ingress/contamination (check valve/filter)
Are instruments suitable for both gases and liquids?
Many handhelds handle gaseous and liquid media. Check datasheets for media compatibility and any oil/medium contact notes.
How do I perform zeroing?
Vent the sensor to ambient (no pressure), then press Zero/Tare. For absolute pressure, consider barometric variation.
Are very low ranges available?
Yes—low-pressure/manometric ranges (mbar/Pa) and high-resolution differential gauges for filter/room-pressure applications.
Can the instruments be calibrated?
Yes, optionally with ISO or DAkkS certificate. Recommendation: annual calibration, more frequent for QA-critical applications.
Do the devices support Peak/Min/Max capture?
Many models provide Min/Max/Peak-Hold for fast events; sampling rate and digital damping are configurable.
How do I integrate results into my documentation?
Via CSV/Excel export, PDF reports from software, or direct interfaces (USB/BT). Document tag, unit, time base (UTC), and environmental conditions.
Are ATEX-approved handhelds available?
Yes, selected models with ATEX/IECEx. Observe the protection concept (e.g., Ex ia) and permissible accessories/adapters.
Do you help with selection and accessories?
Yes. We recommend the right range, accuracy class, adapters/couplings, test pumps, calibration certificates, and—on request—data/IIoT integration.












































































































































































Datasheet
Datasheet
Datasheet