Housing 48 x 24 mm
Display 4-digit 10 mm digit height Colour: red, green, orange or blue display
Range displayed -1999 to 9999
Operation front panel keyboard protection class IP65
Input 0/4-20 mA / Span -22…24 mA 0-10 VDC / Span -12…12 VDC
Analogue Output
Switch point
Interface
Power supply 24 VDC +/-10% galvanic isolated Other voltage supplies on demand!
Sensor supply
Software properties
  • Min/Max-value recording
  • 10 adjustable supporting point
  • display flashing at threshold exceedance/undercut
  • navigation keys for polling of min/max-values or for threshold corrections during operation
  • Tara-function
  • programming interlock via access code
Datasheet
User Manual

Housing 48 x 24 mm
Display 5-digit 10 mm digit height Colour: red, green, orange or blue display
Range displayed -19999 to 99999
Operation front panel keyboard protection class IP65
Input 0/4-20 mA / Span -22…24 mA 0-10 VDC / Span -12…12 VDC Digital input: <2.4V OFF, >10V ON, max. 30 VDC
Analogue Output 0/4-20 mA / 0-10 VDC / 16 Bit Alternatively sensor supply
Switch point 2 PhotoMos outputs (NOC) 30 VDC/AC, 0.4 A
Interface
Power supply 24 VDC galvanic isolated 100-240 VAC 50/60 Hz / DC +/- 10%
Sensor supply 10 VDC / 20 mA, incl. digital input 24 VDC / 50 mA, incl. digital input Alternatively analog output
Software properties
  • min/max-memory with adjustable permanent display
  • 30 additional adjustable supporting points
  • display flashing at threshold value exceedance/undercut
  • navigation keys for the triggering of Hold, Tara, display change, setpoint setting, alarm actuator
  • flexible alarm system with adjustable delay times
  • volume metering (Totaliser)
  • mathematical functions like reciprocal value, square root, squaring and rounding
  • constant setting/setpoint setting
  • sliding averaging
  • brightness control via parameter or front keys
  • programming interlock via access code
Datasheet
User Manual

Housing 72 x 36 mm
Display 4-digit 14 mm digit height Colour: red, green, orange or blue display
Range displayed -1999 to 9999
Operation front panel keyboard protection class IP65
Input 0/4-20 mA / Span -22…24 mA 0-10 VDC / Span -12…12 VDC
Analogue Output
Switch point 2 relays (change-over contact) 250 V / 5 AAC, 30 V / 5 ADC
Interface
Power supply 24 VDC +/-10% galvanic isolated 230 VAC Other voltage supplies on demand!
Sensor supply
Software properties
  • Min/Max-value recording
  • 10 adjustable supporting point
  • display flashing at threshold exceedance/undercut
  • navigation keys for polling of min/max-values or for threshold corrections during operation
  • Tara-function
  • programming interlock via access code
Datasheet
User Manual

Housing 96 x 24 mm
Display 4-digit 14 mm digit height Colour: red, green, orange or blue display
Range displayed -1999 to 9999
Operation front panel keyboard protection class IP65
Input 0/4-20 mA / Span -22…24 mA 0-10 VDC / Span -12…12 VDC
Analogue Output
Switch point
Interface
Power supply 230 VAC 24 VDC +/-10% galvanic isolated Other voltage supplies on demand!
Sensor supply
Software properties
  • Min/Max-value recording
  • 10 adjustable supporting point
  • display flashing at threshold exceedance/undercut
  • navigation keys for polling of min/max-values or for threshold corrections during operation
  • Tara-function
  • programming interlock via access code
Datasheet
User Manual

Housing 96 x 24 mm
Display 5-digit 14 mm digit height Colour: red, green, orange or blue display
Range displayed -19999 to 99999
Operation front panel keyboard protection class IP65
Input 0/4-20 mA / Span -22…24 mA 0-10 VDC / Span -12…12 VDC Digital input: <2.4V OFF, >10V ON, max. 30 VDC
Analogue Output 0/4-20 mA / 0-10 VDC / 16 Bit Alternatively interface RS232/RS485
Switch point 1 or 2 change-over relays 250 VAC / 2 AAC ; 30 VDC / 2 ADC
Interface RS232 or RS485 galvanic isolated Alternatively analog output
Power supply 100-240 VAC 50/60 Hz / DC +/- 10% 10-40 VDC / 18-30 VAC 50/60Hz
Sensor supply 10 VDC / 50 mA, incl. digital input 24 VDC / 50 mA, incl. digital input
Software properties
  • min/max-memory with adjustable permanent display
  • 30 additional adjustable supporting points
  • display flashing at threshold value exceedance/undercut
  • navigation keys for triggering of Hold, Tara, display change, setpoint setting, alarm actuator
  • flexible alarm system with adjustable delay times
  • volume metering (Totaliser)
  • mathematical functions like reciprocal value, square root, squaring and rounding
  • constant setting/setpoint setting
  • sliding averaging
  • brightness control via parameter or front keys
  • programming interlock via access code
Datasheet
User Manual

Housing 96 x 48 mm
Display 4-digit 14 mm digit height Colour: red, green, orange or blue display
Range displayed -1999 to 9999
Operation front panel keyboard protection class IP65
Input 0/4-20 mA / Span -22…24 mA 0-10 VDC / Span -12…12 VDC
Analogue Output
Switch point
Interface
Power supply 230 VAC 24 VDC +/-10% galvanic isolated Other voltage supplies on demand!
Sensor supply
Software properties
  • Min/Max-value recording
  • 10 adjustable supporting point
  • display flashing at threshold exceedance/undercut
  • navigation keys for polling of min/max-values or for threshold corrections during operation
  • Tara-function
  • programming interlock via access code
Datasheet
User Manual

Housing 96 x 48 mm
Display 5-digit 14 mm digit height Colour: red, green, orange or blue display
Range displayed -19999 to 99999
Operation front panel keyboard protection class IP65
Input 0/4-20 mA / Span -22…24 mA 0-10 VDC / Span -12…12 VDC Digital input: <2.4V OFF, >10V ON, max. 30 VDC
Analogue Output 0/4-20 mA / 0-10 VDC / 16 Bit Alternatively sensor supply
Switch point 2 relays (change-over contact) 250 V / 5 AAC, 30 V / 5 ADC
Interface
Power supply 230 VAC 10-30 VDC galvanic isolated Other voltage supplies on demand!
Sensor supply 10 VDC / 20 mA, incl. digital input 24 VDC / 50 mA, incl. digital input Alternatively analog output
Software properties
  • min/max-memory with adjustable permanent display
  • 30 additional adjustable supporting points
  • display flashing at threshold value exceedance/undercut
  • zero-key for triggering of Hold, Tara, display change, setpoint setting, alarm actuator
  • flexible alarm system with adjustable delay times
  • volume metering (Totalisator)
  • mathematical functions like reciprocal value, square root, squaring and rounding
  • constant setting/setpoint setting
  • sliding averaging
  • brightness control via parameter or front keys
  • programming interlock via access code
Datasheet
User Manual

 

Housing 96 x 48 mm
Display 5-digit 14 mm digit height Colour: red, green, orange or blue display
Range displayed -19999 to 99999
Operation front panel keyboard protection class IP65
Input 0/4-20 mA / Span -22…24 mA 0-10 VDC / Span -12…12 VDC Digital input: <2.4V OFF, >10V ON, max. 30 VDC
Analogue Output 2 analog outputs 0/4-20 mA / 0-10 VDC / 16 Bit
Switch point 2 or 4 relays (change-over contacts) 250 V / 5 AAC, 30 V / 5 ADC or 8 PhotoMos outputs (NOC) 30 V / 0.4 A AC/DC
Interface RS232 or RS485 galvanic isolated Alternatively to analog output 2
Power supply 100-240 VAC 50/60 Hz / DC +/- 10% 10-40 VDC / 18-30 VAC 50/60Hz
Sensor supply 10 VDC / 20 mA, incl. digital input 24 VDC / 50 mA, incl. digital input
Software properties
  • min/max-memory with adjustable permanent display
  • 30 additional adjustable supporting points
  • display flashing at threshold value exceedance/undercut
  • zero-key for triggering of Hold, Tara, display change, setpoint setting, alarm actuator
  • flexible alarm system with adjustable delay times
  • volume metering (Totaliser)
  • mathematical functions like reciprocal value, square root, squaring and rounding
  • constant setting/setpoint setting
  • sliding averaging
  • brightness control via parameter or front keys
  • programming interlock via access code
Datasheet
User Manual

Housing 96 x 96 mm
Display 4-digit 20 mm digit height Colour: red
Range displayed -999…9999
Operation front panel keyboard protection class IP65
Input 0…10 VDC 0/4…20 mA
Analogue Output
Switch point 2 relays (change-over contact) 250 V / 5 AAC, 30 V / 5 ADC
Interface
Power supply 230 VAC
Sensor supply 24 VDC / 50 mA
Software properties
  • min/max-memory
  • 10 additional adjustable supporting points
  • display flashing at threshold value exceedance/undercut
  • zero point slowdown
  • Hold-/Tara-function
  • programming interlock via access code
Datasheet


Digital DC Voltage / DC Current Panel Meters (ICS)

Digital DC panel meters in the “DC Voltage / DC Current (ICS)” category are designed for precise measurement of DC voltages and currents in control cabinets and industrial systems. They capture the input signal via an internal measurement stage, convert it into digital values using an ADC and display the results clearly on an LED or LCD screen. These meters are ideal for monitoring battery systems, DC power distribution, photovoltaic systems, charging and testing equipment and a wide range of industrial applications involving direct current.

F&A

What is a digital DC voltage or DC current panel meter?

A digital DC panel meter measures DC voltage (VDC) or DC current (ADC) and displays the value numerically. It is intended for fixed installation in control cabinets, switchboards or distribution systems and ensures reliable monitoring of DC circuits.

Which quantities can be measured?

Depending on the model, the device measures either DC voltage, DC current or both. For higher currents, external shunts are typically used, which the meter evaluates.

How does the measurement work?

The analog DC signal is captured by the input stage, digitized using an analog-to-digital converter and processed by the internal electronics. The result is shown as a stable and precise numerical value on the display.

What are the advantages of digital meters over analog ones?

Digital meters provide precise and clear readings without pointer or parallax errors. They often offer higher accuracy, better stability, compact panel sizes and additional functions such as min/max storage, alarm or limit functions and output signals.

Where are digital DC panel meters used?

Typical applications include battery and UPS systems, DC distribution boards, charging equipment, PV installations, automation systems, test benches and industrial DC supply systems.

Which display and output options are available?

They usually feature LED or LCD displays. Many devices additionally offer relay outputs, analog outputs (e.g. 4–20 mA or 0–10 V), alarm functions or – depending on the model – digital communication interfaces.

What should be considered when selecting a DC panel meter?

Important criteria include the voltage/current range, accuracy, input type (direct or via shunt), display type and size, supply voltage, required additional functions (e.g. alarm, analog output) and compatibility with the system’s environmental conditions.

Can digital DC meters replace analog instruments?

Yes — a single digital meter can often replace separate analog voltmeters and ammeters, saving panel space while improving readability and offering more functionality.

Are there limitations?

Digital meters require a stable auxiliary power supply. Very low currents or noisy signals may require appropriate ranges, filtering or external shunts. EMC environment and protection rating should also be considered.

Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.