The DPI610E not only delivers highly accurate measurements – it does so for a wide variety of pressure ranges (350mbar / 5 psi / 33 kPa to 1000bar /15000 psi / 100 MPa ). That means one device can cover all your calibration needs – reducing both cost of ownership and maintenance.
![]() |
![]() |
![]() |
- 41 pressure ranges from ±25 mbar to 1,400 bar (±10 inH20 to 20,000 psi/2.5 kPa to 140 MPa)
- Total 1 year uncertainty down to 0.025% full scale (FS) over temperature range of -10°C to +50°C
- Integral calibration record with calibration due count-down display
- Leak test, tare, maximum/minimum and filter functions
- Hazardous Area (Intrinsically safe) version available
- Optional remote plug and play pressure (PM700E) and Resistance Temperature Detector (RTD-PROBE) sensors
![]() |
![]() |
- 50% smaller and 33% lighter than the DPI 610
- Generates 0 to 20 bar/300 psi in less than 30 seconds
- Creates 95% vacuum
- Pressure measurement is twice as accurate
- Three times better electrical accuracy
- Simplified touch screen interface with application DASHBOARD, quick TASK selection and FAVOURITES storage
- Fast, three touch set-up for any application
- Calculates PASS/FAIL errors, documents results and interfaces with calibration software
- Provided with one free 4Sight2 Lite calibration software license
![]() |
![]() |
- The complete pressure calibration tool: pump, measure, analyze
- Best in class pressure accuracy
- Fast and dependable from vacuum to 1000 bar/15000 psi
- Easy to use touch screen
- No in-the-field leaks with quick-to-fit pressure adapters and hoses
- Provided with one free 4Sight2 Lite calibration software license
![]() |
![]() |
DPI620 GENII Multi-Function Process Calibrator and HART Communicator for safe and hazardous area use
- Multi-function capabilities: electrical, frequency, temperature and pressure
- Optional HART and Foundation Fieldbus communicators
- ATEX, IECEx and ETL approved for hazardous area use
- Modular re-rangeable and expandable concept
- Individual components can be used as stand-alone instruments
- Allows significant inventory reductions
- Simplifies training and improves operator safety
- Reduces cost of ownership
- Provided with one free 4Sight2 Lite calibration software license


![]() |
![]() |
![]() |
- Digital indicator with interchangeable pressure sensors (plug-and-play)
- Measuring ranges from 0 ... 25 mbar to 0 ... 1,000 bar (0 ... 0.4 psi to 0 ... 14,500 psi)
- Type of pressure: positive and negative overpressure, absolute pressure and differential pressure
- Accuracy: 0.2 %, optional 0.1 % (incl. calibration certificate)
- Software and complete service cases (incl. pumps) available
![]() |
![]() |
- Intrinsically safe indicator with interchangeable pressure sensors model CPT62I0 (plug-and-play)
- Measuring ranges 0 ... 1,000 bar [0 ... 14,500 psi]
- Type of pressure: Positive and negative overpressure, absolute pressure and differential pressure
- Accuracy: 0.2 %, optionally 0.1 % (incl. calibration certificate)
- Data logger for recording measured values

![]() |
![]() |
- Robust and waterproof digital indicator with interchangeable pressure sensors (plug-and-play)
- Measuring ranges from 0 ... 25 mbar to 0 ... 1,000 bar (0 ... 0.4 psi to 0 ... 14,500 psi)
- Pressure type: positive and negative gauge pressure, absolute pressure and differential pressure
- Accuracy: 0.2 %, optional 0.1 % (incl. calibration certificate)
- Software and complete service cases (incl. pumps) available
![]() |
![]() |
A wide variety of reference pressure sensors, offering various measuring ranges of up to 6,000 bar (75,000 psi), are available to the operator, always ensuring a solution matched to the application.
![]() |
![]() |
- handheld pressure calibrator with easily interchangeable reference pressure sensors (sensor can also be attached externally)
- Measuring ranges from 0 ... 4 psi to 0 ... 116,000 psi (0 ... 250 mbar to 0 ... 8,000 bar )
- Accuracy: 0.025 % (incl. calibration certificate)
- Calibration and pressure-switch test functions
- Software and complete service cases (incl. pumps) available
![]() |
![]() |
![]() |
![]() |
- Measurement and simulation of the following parameters: pressure, electrical signals (mA, mV, V, Ω), temperature (TC, RTD), frequency and pulse
- Large colour touchscreen display with new intuitive and user-friendly interface
- Internal pressure/vacuum generation
- Option: intrinsically safe version, II 2G Ex ib IIC T4 Gb - Tamb: -10 ... +50 °C
- Option: integrated HART® module for communication with HART® instruments

![]() |
![]() |
![]() |
![]() |
- 0.02%, 0.05% FS Accuracy
- Intrinsically Safe
- Field Switchable Pressure Module
- Dual Digital Pressure Module Inputs
- Color Touchscreen Display
- Built-in Quick Test Task Feature
- Built-in Barometer
- Intuitive Smartphone Like Interface
- Bluetooth and USB Communication
- Optional HART Communication
- Communicates with Additel's Link Mobile App
- ISO 17025-accredited calibration w/data included

![]() |
The Additel 760 series Automatic Handheld Pressure Calibrator takes portable pressure calibration to new levels. Weighing less than 4 lbs (1.8 kg), the ADT760’s innovative design contains a built-in pump, precision pressure sensor, internal controller and a large touch-screen color display.
![]() |
![]() |
![]() |
- max. Pressure range: -0,86 bar up to 2,5 bar
- Accuracy: 0,02% v.E.
- Stability: 0,005% v.E.
![]() |
![]() |
![]() |
- max. Pressure range: ±75 mbar
- Accuracy: 0,05% v.E.
- Stability: 0,005% v.E.
![]() |
![]() |
![]() |
- max. Pressure range: -0,86 bar up to 20 bar
- Accuracy: 0,02% v.E.
- Stability: 0,005% v.E.
![]() |
![]() |
![]() |
- Automated and self-contained pressure generation and control from -0.9 bar to 70 bar (1,000) psi
- Standard accuracy to 0.02% of Span*
- Optional precision accuracy models up to 0.01% of Span
- Two removable internal pressure modules for multi-range selection
- Control stability to 0.003% of Span
- Portable, designed for use in the field and in the lab
- Ability to measure two external pressure modules
- Wi-Fi, Bluetooth, USB and Ethernet communication
- HART and profibus communication
- Data logging and task management
- Patented electric pump technology and improved speed
![]() |
![]() |
![]() |
![]() |
- Automated and self-contained pressure generation and control from -0.9 bar to 70 bar (1,000) psi
- Standard accuracy to 0.01% of Span*
- Optional precision accuracy models up to 0.01% of Span
- Two removable internal pressure modules for multi-range selection
- Control stability to 0.003% of Span
- Portable, designed for use in the field and in the lab
- Ability to measure two external pressure modules
- Wi-Fi, Bluetooth, USB and Ethernet communication
- HART and profibus communication
- Data logging and task management
- Patented electric pump technology and improved speed
![]() |
![]() |
![]() |
![]() |
- Automated and self-contained pressure generation and control from 100 hPa to 1200 hPa
- Standard accuracy to 0.01% FS
- Optional precision accuracy models up to 0.01% FS
- Two removable internal pressure modules for multi-range selection
- Control stability to 0.02 hPa
- Portable, designed for use in the field and in the lab
- Ability to measure two external pressure modules
- Wi-Fi, Bluetooth, USB and Ethernet communication
- HART and profibus communication
- Data logging and task management
- Patented electric pump technology and improved speed
![]() |
![]() |
![]() |
![]() |
- Automated and self-contained pressure generation and control from -0.9 bar to 2.5 bar (35) psi
- Standard accuracy to 0.02% of Span*
- Optional precision accuracy models up to 0.01% of Span
- Two removable internal pressure modules for multi-range selection
- Control stability to 0.005% of Span
- Portable, designed for use in the field and in the lab
- Ability to measure two external pressure modules
- Wi-Fi, Bluetooth, USB and Ethernet communication
- HART and profibus communication
- Data logging and task management
- Patented electric pump technology and improved speed
![]() |
![]() |
![]() |
![]() |
- Measuring Range: ±50 mbar and ±75 mbar
- Accuracy: 0,05 % o.S.
- Two removable internal pressure modules
- Built-in electric pump can set accurate pressure quickly
- Differential pressure, Gauge Pressure. Absolut pressure, Barometric pressure
- Easy Handling
- The perfect air pipeline protection can effectively avoid blockage and leakage problems
- Built-in battery (8 hours run)
- compact size
- for calibration laboratories, workplace and on-site calibrations
![]() |
![]() |
![]() |
- Automated pressure generation and control to 10,000 psi (700 Bar)
- Accuracy to 0.01%FS
- Dual-range manual or auto select
- Control stability ≤ 0.005%FS
- Portable - designed for use in the field and in the lab
- Control by optional external pressure modules
- Supports two external pressure modules
- Wi-Fi, LAN, Bluetooth, USB and Ethernet communication
- Full HART field communicator
- HART and PROFIBUS communication
- Data logging and task management
- Patented electric pump technology
![]() |
ICP 40.2 - Precision Hand Pressure Pump
- Testing, adjustment and calibration of all types of pressure gauges
- 3 in 1: vacuum, low pressure and medium pressure calibration
- Exact setting in the mbar range thanks to the ultra-fine thread pitch and large-volume control valve
- Tool-free change between overpressure and vacuum generation
- Measuring ranges up to 0 ... 1,000 bar (0 ... 15,000 psi), vacuum and absolute pressure ranges also available
- Accuracy: up to 0.05 % (incl. calibration certificate)
- Intrinsically safe version
- Logger function with up to 50 measured values per second
- Communication with WIKA-CAL software over WIKA-Wireless

![]() |
![]() |
![]() |
Any number of remote sensors can be individually used with a single DPI610E as all sensors hold their own calibration data and are supplied with a 2.9m (9.5 feet) cable.
![]() |