Showing 1–10 of 25 results

  • 2 year warranty and 60 years of Dynisco industry experience
  • Accuracy better than ±0.5%
  • TiAlN diaphragm coating is standard
  • mV/V, 0-10VDC, or mA outputs available
  • Integral temperature sensor option
  • Available in configurations that fit most extruder applications
  • 1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability
Datasheet

  • Integral relay switch for redundant safety and future compliance
  • 3rd-party agency analysis (exida™) and self-certified based on FMEDA analysis and internal audit.
  • Meets Performance Level ‘c’ as defined by the Machinery Directive (single sensor installed per Category 1).
  • Meets Performance Level ‘d’ as defined by the Machinery Directive (two sensors installed per Category 3).
  • Meets the following compliance directives, when properly installed and used:
    • Machinery Directive 2006/42/EC
    • NFPA 79 clauses A.9.2, A.9.4.1, A.9.4.3.2
    • EMC Directive 2004/108/EC
    • PED 97/23/EC
  • Available on popular mV/V (PT, MDA, DYN) and mA-HART SPX models
Datasheet

  • Adjustable zero and span, via side-mounted pots
  • Accuracy better than ±1.0%
  • DyMaxÂź coated stainless steel wetted parts
  • 4-20 mA output
  • 0-500 to 0-30,000 psi
  • Internal 80% shunt calibration
Datasheet

  • Adjustable zero and span
  • Accuracy better than ±1.0%
  • DyMaxÂź coated stainless steel wetted parts
  • 0 - 10 Vdc outputs
  • 0 - 500 to 0 - 10,000 psi
  • Internal 80% shunt calibrations
Datasheet

  • Economical and repeatable pressure meausurements
  • Superior abrasion resistance
  • Stability and repeatability
  • Variety of pressure ranges
  • Easy to calibrate
Datasheet

  • Accuracy better than ±0.25%
  • DyMaxÂź coated stainless steel wetted parts
  • Proven sensor design
  • Excellent thermal stability and repeatability
  • 0 - 500 to 0 -30,000 psi
  • Internal 80% shunt calibration
Datasheet

  • Accuracy better than ±0.5%
  • DyMaxÂź coated stainless steel wetted parts
  • Proven sensor design
  • 0 - 500 to 0 -30,000 psi
  • Internal 80% shunt calibration
Datasheet

  • Accuracy of better than ±0.25%
  • Choice of flanged or threaded configurations
  • 0 - 250 to 0 - 10,000 psi
  • Withstands processes up to 700°F
  • Internal 80% shunt calibration
  • Replacement for traditional “button - seal” units
Datasheet

  • Accuracy better than ±0.5%
  • DyMaxÂź coated stainless steel wetted parts
  • Proven sensor design
  • 0 - 500 to 0 -30,000 psi
  • Internal 80% shunt calibration
Datasheet

  • Output: 3.33 mV/V +/- 2.0%
  • Input Voltage: 10 Vdc recommended, 12 Vdc maximum
  • Combined Error: +/- 0.25% FSO, (Including Linearity, Repeatability & Hysteresis) +/- 0.5% FSO for 500, 750, 1,000 psi ranges
  • Repeatability: +/- 0.1%FSO, +/- 0.2% FSO for 500, 750, 1,000 psi ranges
  • Configuration: Four-arm bonded foil Wheatstone bridge strain gage
  • Bridge Resistance: Input: 345 Ohms minimum, Output: 350 Ohms +/- 10%
  • Over Pressure: 2 X FSO or 35,000 psi whichever is less
  • Zero Balance: +/- 5% FSO
  • Internal Shunt Calibration (R-Cal): 80% FSO +/- 0.5%
  • Insulation Resistance: 1000 megohms @ 50 Vdc
Datasheet