- 2 year warranty and 60 years of Dynisco industry experience
- Accuracy better than ±0.5%
- TiAlN diaphragm coating is standard
- mV/V, 0-10VDC, or mA outputs available
- Integral temperature sensor option
- Available in configurations that fit most extruder applications
- 1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability
![]() |
- Integral relay switch for redundant safety and future compliance
- 3rd-party agency analysis (exida™) and self-certified based on FMEDA analysis and internal audit.
- Meets Performance Level ‘c’ as defined by the Machinery Directive (single sensor installed per Category 1).
- Meets Performance Level ‘d’ as defined by the Machinery Directive (two sensors installed per Category 3).
- Meets the following compliance directives, when properly installed and used:
- Machinery Directive 2006/42/EC
- NFPA 79 clauses A.9.2, A.9.4.1, A.9.4.3.2
- EMC Directive 2004/108/EC
- PED 97/23/EC
- Available on popular mV/V (PT, MDA, DYN) and mA-HART SPX models
![]() |
- Adjustable zero and span, via side-mounted pots
- Accuracy better than ±1.0%
- DyMax® coated stainless steel wetted parts
- 4-20 mA output
- 0-500 to 0-30,000 psi
- Internal 80% shunt calibration
![]() |
- Adjustable zero and span
- Accuracy better than ±1.0%
- DyMax® coated stainless steel wetted parts
- 0 - 10 Vdc outputs
- 0 - 500 to 0 - 10,000 psi
- Internal 80% shunt calibrations
![]() |
- Economical and repeatable pressure meausurements
- Superior abrasion resistance
- Stability and repeatability
- Variety of pressure ranges
- Easy to calibrate
![]() |
- Accuracy better than ±0.25%
- DyMax® coated stainless steel wetted parts
- Proven sensor design
- Excellent thermal stability and repeatability
- 0 - 500 to 0 -30,000 psi
- Internal 80% shunt calibration
![]() |
- Accuracy better than ±0.5%
- DyMax® coated stainless steel wetted parts
- Proven sensor design
- 0 - 500 to 0 -30,000 psi
- Internal 80% shunt calibration
![]() |
- Accuracy of better than ±0.25%
- Choice of flanged or threaded configurations
- 0 - 250 to 0 - 10,000 psi
- Withstands processes up to 700°F
- Internal 80% shunt calibration
- Replacement for traditional “button - seal” units
![]() |
- Accuracy better than ±0.5%
- DyMax® coated stainless steel wetted parts
- Proven sensor design
- 0 - 500 to 0 -30,000 psi
- Internal 80% shunt calibration
![]() |
- Output: 3.33 mV/V +/- 2.0%
- Input Voltage: 10 Vdc recommended, 12 Vdc maximum
- Combined Error: +/- 0.25% FSO, (Including Linearity, Repeatability & Hysteresis) +/- 0.5% FSO for 500, 750, 1,000 psi ranges
- Repeatability: +/- 0.1%FSO, +/- 0.2% FSO for 500, 750, 1,000 psi ranges
- Configuration: Four-arm bonded foil Wheatstone bridge strain gage
- Bridge Resistance: Input: 345 Ohms minimum, Output: 350 Ohms +/- 10%
- Over Pressure: 2 X FSO or 35,000 psi whichever is less
- Zero Balance: +/- 5% FSO
- Internal Shunt Calibration (R-Cal): 80% FSO +/- 0.5%
- Insulation Resistance: 1000 megohms @ 50 Vdc
![]() |
- 6 mm sensing element
- Fits in space restricted areas
- Exposed, bendable capillary
- Ideal for injection molding nozzles
- Internal 80% shunt calibration
- Easy set - up
- 0 - 5,000 to 0 - 10,000 psi
- Choice of pressure ranges
- Good stability and repeatability
- Proven sensor design
- Flexible stem
- Easy to install, ideal for high local temperatures
- Classic, standard design
- Economically priced
![]() |
- 6 mm sensing element
- Fits in space restricted areas, reduces mounting hole dead space
- Internal 80% shunt calibration
- Easy set - up
- 0 - 5,000 to 0 - 10,000 psi
- Choice of pressure ranges
- Good stability and repeatability
- Reliable pressure measurement
- Flexible stem • Easy to install and ideal for high local temperatures
![]() |
- Accuracy better than ±1.0%
- Inconel diaphragm
- Superior temperature stability
- Patented sensing element
- 0 - 3,000 to 0 -30,000 psi
- Internal 80% shunt calibration
![]() |
- Accuracy of better than ±1.0%
- Reliable pressure measurement
- Four user selectable pressure ranges in one model
- Maximizes inventory flexibility
- Externally selectable range via rotary switch
- Maximum versatility for changing process conditions
- 3.33 mV/V FSO for selected range
- Standard low level output
- Internal 80% shunt calibration
- Easy set-up
- All stainless steel wetted parts
- Corrosion resistant
- Proven sensor design
- Good stability and repeatability
![]() |
- Accuracy of better than ±1.0% • Reliable pressure measurement
- Four user selectable pressure ranges in one model
- Maximizes inventory flexibility
- Externally selectable range via rotary switch
- Maximum versatility for changing process conditions
- 3.33 mV/V FSO for selected range
- Standard low level output
- Internal 80% shunt calibration
- Easy set-up
- All stainless steel wetted parts
- Corrosion resistant
- Proven sensor design
- Good stability and repeatability
- Type J thermocouple
- Simultaneously measure pressure/temperature in one location
![]() |
Die Druckaufnehmer der Serie MDA liefern über ein geschlossenes, flüssigkeitsgefülltes Druckmittlersystem ein zum anstehenden Prozessdruck proportionales Ausgangssignal.
![]() |
The pressure transducers of the MDA series supply an output signal that is proportional to the process pressure via a closed, liquid-filled diaphragm seal system.
![]() |
- Installation for media temperature up to 400 °C
- l Flexible capillary between rigid stem and housing
- l Liquid-filled transmission system
- l Electrical built-in calibration
![]() |
- Accuracy better than +/- 0.5%
- Dymax® coated stainless steel wetted parts
- Proven sensor design
- 0 - 500 to 0 -30,000 psi
- Internal 80% shunt calibration
- Reliable, repeatable pressure measurements
- Superior abrasion resistance
- Good stability and repeatability
- Wide variety of pressure ranges
- Easy to calibrate with local indicator
![]() |
- Installation for media temperature up to 400 °C
- l Flexible capillary between rigid stem and housing
- l Liquid-filled transmission system
- l Electrical built-in calibration
![]() |
The pressure transmitters of the TDA series are based on the proven MDA series. They supply an output signal that is proportional to the process pressure via a closed, liquid-filled diaphragm seal system. Thanks to the integrated thermocouple, it is possible to measure the temperature directly on the medium at the same time.
![]() |
- Installation for media temperature up to 400 °C
- l Integral thermocouple for simultaneous temperature measurement at the media
- l Flexible capillary between rigid stem and housing
- l Liquid-filled transmission system
- l Electrical built-in calibration
![]() |
- Better than ±0.5% accuracy
- 4 to 20 mA, 0 to 5 Vdc, 1 to 6 Vdc, 0 to10 Vdc, 1 to 11 Vdc outputs
- Stainless steel, Armoloy coated
- 0 - 500 to 0 - 30,000 psi
- Internal 80% shunt calibration
- Adjustable zero and span
- Integral thermocouple
- Reliable pressure measurement
- Direct input to supervisory control systems
- Minimizes thread galling, abrasion resistant
- Choice of pressure ranges
- Easy set-up
- Adapt transmitter to process conditions
- Simultaneously measure pressure/temperature in one location
![]() |
- Better than ±0.5% accuracy
- 4 to 20 mA, 0 to 5 Vdc, 1 to 6 Vdc, 0 to10 Vdc, 1 to 11 Vdc outputs
- Stainless steel, Armoloy coated
- 0 - 500 to 0 - 30,000 psi
- Internal 80% shunt calibration
- Adjustable zero and span
- Integral thermocouple
- Reliable pressure measurement
- Direct input to supervisory control systems
- Minimizes thread galling, abrasion resistant
- Choice of pressure ranges
- Easy set-up
- Adapt transmitter to process conditions
- Simultaneously measure pressure/temperature in one location
![]() |
- Better than ±0.5% accuracy
- 4 to 20 mA, 0 to 5 Vdc, 1 to 6 Vdc, 0 to10 Vdc, 1 to 11 Vdc outputs
- Stainless steel, Armoloy coated
- 0 - 500 to 0 - 30,000 psi
- Internal 80% shunt calibration
- Adjustable zero and span
- Integral thermocouple
- Reliable pressure measurement
- Direct input to supervisory control systems
- Minimizes thread galling, abrasion resistant
- Choice of pressure ranges
- Easy set-up
- Adapt transmitter to process conditions
- Simultaneously measure pressure/temperature in one location
![]() |