- all in one design: Bi-directional inverter and charger
- 3-stage charging function
- intelligent software for energy management: performance division and generator function
- hardwired connection
- fan controls at load and temperature
- remote management and control
- RS 232 cummunication interface
- extented protection features
- input overvoltage / Input voltage / overtemperature / overload / short circuit / reverse Polarity (internal fuse)
![]() |
- Parallel connection of up to 15 SD devices for power expansion (max. 52kW AC power)
- Integrated transfer circuit for synchronous network switching
- 3-phase current with parallel connection from 3 SD devices. Significant increase in performance thanks to N+X parallel design, up to 30% weight and volume reduction
- Designed for use in harsh environments (-20°~ +60°)
- Meets safety and EMC requirements
- High-tech - robust - inexpensive
- Ideal combination with COTEC CX loading machines (15~80A/ 12-24 V)
![]() |
- True sine wave output (THD<3% at rated-VDC, linear load)
- Power ON/OFF - Remote Control
- Input & Output fully isolation
- Output frequency 50/60 Hz DIP-switch
- Output voltage / power saving mode selectable
- Input protection: Reverse Polarity (Fuse) / undervoltage- / overvoltage protection
- Output protection: Short circuit / overload / over temperature protection
- Energy Saving Mode < 2W
- FCC class B certified
![]() |
- Pure sine wave output (THD <5% @ Normal Ladung@12.5V / 25V / 50V)
- RS-232 communication
- Power ON / OFF remote control (Green Terminal).
- Remote controller CR 8 / CR16 operating (user selectable).
- Input & Output fully insulated and temperature-controlled fan load
- Built-up microprocessor for user-friendly interface
- Output frequency 50/60 Hz
- DIP switch
- Output voltage DIP switch
- Energy saving mode adjustable resistor selectable
- Tri-color indicators display status
- AC transfer function Accessories (TR40)
- Protection: Input over-voltage / input voltage / over temperature / overload / short-circuit / reverse polarity (internal fuse)
![]() |
- Pure sine wave output (THD < 2%)
- Standard 19” 1U rack mount
- User-friendly LCM module
- Dry contact for system alarm
- RS-232 communication port
- Selectable on-line / off-line modes
- Built in AC transfer switch and AC breaker
- Hard-wire or dual AC outlet output connection
- Fan failure alarm with buzzer
- Input protection: Reverse Polarity (Fuse) / Under Voltage / Over Voltage
- Output protection: Short Circuit / Over Temperature
- UL / CE / FCC approved
![]() |