The 2-Channel Isolation Amplifier DN 26000 is used for isolation and conversion of 0/4 ... 20 mA and 0 ... 10 V, 0 … 5 V standard signals.
- Calibrated signal setting via DIP switch Input and output range can be set by using DIP switch – high precision without any further adjustment
- 5-Port Isolation Protection against erroneous measurements due to parasitic voltages or ground loops
- Extremely slim design 6.2 mm slim housing for a simple and space saving DIN rail mounting
- Power supply via In-Rail-connector allows fast and economical installation
- Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage
- Maximum reliability No maintenance costs
- 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
![]() |
![]() |
The Isolation Amplifier DB 6200 is used for isolation and conversion of bipolar and unipolar industrial signals.
- Easy selection of input and output range Input and output range for unipolar and bipolar signals can be easily set by using DIP switch
- Universal power supply for 20...253 V AC/DC Applicable world-wide for all common supply voltages
- 3-port isolation Protection against erroneous measurements due to parasitic voltages or ground loops
- Ultra small sized housing 12.5 mm housing with plug-in screw terminal blocks
- High bandwidth; high accuracy No distortion; no falsification of measured signal
- Protective Separation Protects service personnel and downstream devices against impermissibly high voltage
- Maximum reliability No maintenance costs
- 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
![]() |
![]() |
The Bipolar Isolation Amplifier DB 64000 is used for isolation and conversion of bipolar and unipolar industrial standard signals.
- Calibrated signal setting via DIP switch Input and output range can be set by using DIP switch – high precision without any further adjustment
- High bandwidth; short response time No signal distortion; no falsification of measured signal
- Switchable Zero/Span compensation For readjustment of the sensor or field device
- 3-Port isolation Protection against erroneous measurements due to parasitic voltages or ground loops
- Extremely slim design 6.2 mm slim housing for a simple and space saving DIN rail mounting
- Optional In-Rail-Bus mounting rail connector allows for fast and economical installation
- Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage
- 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
![]() |
![]() |
![]() |
The Isolation Amplifier DB 68 is used for isolation and conversion of bipolar and unipolar standard signals.
- Cost optimized design Economical separation for standard applications
- Only 60 mm installation depth, 11.2 mm wide Can be installed in economical standard terminal boxes
- Fixed ranges, easy to use Ready to use without any settings or adjustments
- Zero/Span compensation on front panel for readjustment of sensor signal or measuring equipment
- True 3-port separation Protection against erroneous measurements due to parasitic voltages or ground loops
- Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage
- Unlimited use with 24 V AC/DC power supply Universally applicable for all measurement and industrial applications
- 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
![]() |
![]() |
The Isolation Amplifier DK 8000 is used for isolation and conversion of customer-specific industrial signals.
- Customer-Specific Solutions Special Input ant output range on request
- Universal Power Supply for 20 to 253 V AC/DC Applicable world-wide for all common supply voltages
- 3-port isolation Protection against erroneous measurements due to parasitic voltages or ground loops
- Ultra-small-sized housing 12.5 mm housing with plug-in screw terminal blocks
- High accuracy No falsification of measured signal
- Protective Separation Protects service personnel and downstream devices against impermissibly high voltage
- Maximum reliability No maintenance costs
- 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
![]() |
![]() |
The Filter Isolation Amplifier DB 6230 is used for isolation and conversion of bipolar and unipolar industrial signals.
- Easy selection of input and output range Input and output range for unipolar and bipolar signals can be easily set by using DIP switch
- Universal power supply for 20 to 253 V AC/DC Applicable world-wide for all common supply voltages
- 3-port isolation Protection against erroneous measurements due to parasitic voltages or ground loops
- Ultra small sized housing 12.5 mm housing with plug-in screw terminal blocks
- Selectable cut-off frequency; high accuracy No distortion; no falsification of measured signal
- Protective Separation Protects service personnel and downstream devices against impermissibly high voltage
- Maximum reliability No maintenance costs
- 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
![]() |
![]() |
The function signal converter with 4 I/O ports and a switching output is used for acquisition, conversion and galvanic isolation of 0/4 to 20 mA, 0/2 to 10 V standard signals and binary I/O signals.
![]() |
![]() |
The Inverse Isolation Amplifier DB 6250 is used for isolation and conversion of industrial signals with inverse characteristic.
- Easy realization of inverse transmission characteristic Inverse characteristic for unipolar signals can be easily set by using DIP switch
- Universal power pack for 20 to 253 V AC/DC Applicable world-wide for all common supply voltages
- 3-port isolation Protection against erroneous measurements due to parasitic voltages or ground loops
- Ultra small sized housing 12.5 mm housing with plug-in screw terminal blocks
- High bandwidth; high accuracy No distortion; no falsification of measured signal
- Protective Separation Protects service personnel and downstream devices against impermissibly high voltage
- Maximum reliability No maintenance costs
- 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
![]() |
![]() |
The Isolation Amplifier DN 2000 is used for isolation and conversion of 0 to 20 mA, 4 to 20 mA and 0 to 10 V standard signals.
- Calibrated signal setting Input and output range can be set by using DIP switch – without any further adjustment
- Universal Power Supply for 20 ... 253 V AC/DC Applicable world-wide for all common supply voltages
- 3-port isolation Protection against erroneous measurements due to parasitic voltages or ground loops
- Ultra-small-sized housing 12.5 mm housing with plug-in screw terminal blocks
- High accuracy No falsification of measured signal
- Protective Separation Protects service personnel and downstream devices against impermissibly high voltage
- Maximum reliability No maintenance costs
- 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
![]() |
![]() |
The Isolation Amplifier DN 2400 is used for isolation and conversion of 0 to 20 mA, 4 to 20 mA and 0 to 10 V standard signals.
- Cost optimized design Economical separation for standard applications
- Calibrated signal setting Input and output range can be set by using DIP switch – without any further adjustment
- Universal power pack for 20 to 253 V AC/DC Applicable world-wide for all common supply voltages
- 3-port isolation Protection against erroneous measurements due to parasitic voltages or ground loops
- Ultra-small-sized housing 12.5 mm housing with plug-in screw terminal blocks
- Maximum reliability No maintenance costs
- 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
![]() |
![]() |
The Isolation Amplifier DN 25000 is used for isolation and conversion of 0/4 to 20 mA and 0/2 to 10 V standard signals.
- Calibrated signal setting Input and output range can be set by using DIP switch – high precision without any further adjustment
- 3-Port isolation Protection against erroneous measurements due to parasitic voltages or ground loops
- Extremely slim design 6.2 mm slim housing for a simple and space saving DIN rail mounting
- Optional In-Rail-Bus mounting rail connector allows for fast and economical installation
- Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage
- Maximum reliability No maintenance costs
- 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
![]() |
![]() |
![]() |
The Isolation Amplifier DN 28 is used for isolation and conversion of 0 to 20 mA, 4 to 20 mA and 0 to 10 V standard signals.
- Cost optimized design Economical separation for standard applications
- Only 60 mm installation depth, 11.2 mm wide Can be installed in economical standard terminal boxes
- Fixed ranges, easy to use Ready to use without any settings or adjustments
- True 3-port separation Protection against erroneous measurements due to parasitic voltages or ground loops
- Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage
- Unlimited use with 24 V AC/DC power supply Universally applicable for all measurement and industrial applications
- 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
![]() |
![]() |
Isolation Amplifier Module DN 240M – Isolation and Conversion of Standard Signals for PCB Assembling
The Isolation Amplifier DN 240M is used for isolation and conversion of 0 to 20 mA, 4 to 20 mA and 0 to 10 V standard signals.
- Cost optimized design Economical separation for standard applications
- Calibrated signal setting Input and output range can be set by using connector pins - without any further adjustment
- Power Supply for 24 V DC Applicable for standard power supply voltages
- 3-port isolation Protection against erroneous measurements due to parasitic voltages or ground loops
- Ultra-small-sized housing 15.5 mm flat module for pcb assembling
- Maximum reliability No maintenance costs
- 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
![]() |
The Isolation Amplifier DS 7200 is used for separation and conversion of bipolar and unipolar mV-signals such as those frequently used for current measuring with shunt-resistors or other applications.
- Easy selection of input and output range Input and output range for unipolar and bipolar signals can be easily set by using DIP switch
- Universal power supply for 20 to 253 V AC/DC Applicable world-wide for all common supply voltages
- 3-port isolation Protection against erroneous measurements due to parasitic voltages or ground loops
- Ultra small sized housing 12.5 mm housing with plug-in screw terminal blocks
- High bandwidth; high accuracy No distortion; no falsification of measured signal
- Protective Separation, 5 kV Test Voltage Protects service personnel and downstream devices against impermissibly high voltage
- Maximum reliability No maintenance costs
- 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
![]() |
![]() |
The Isolation Amplifier DS 75000 is used for separation and conversion of bipolar and unipolar mV-signals such as those frequently used for current measuring with shunt resistors or other applications with low sensor voltages.
- Calibrated signal setting via DIP switch Input and output range can be set by using DIP switch – high precision without any further adjustment
- High bandwidth; short response time No signal distortion; no falsification of measured signal
- Switchable Zero/Span compensation For readjustment of the shunt/mV signal or measuring section
- 3-Port isolation Protection against erroneous measurements due to parasitic voltages or ground loops
- Extremely slim design 6.2 mm slim housing for a simple and space saving DIN rail mounting
- Optional In-Rail-Bus mounting rail connector allows for fast and economical installation
- Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage
- 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)

![]() |
![]() |
![]() |
The Isolation Amplifier DS 78 is used for isolation and conversion of bipolar and unipolar mV-Signals such as those frequently used for current measuring with shuntresistors or other applications with low sensor voltages.
- Cost optimized design Economical separation for standard applications
- Only 60 mm installation depth, 11.2 mm wide Can be installed in economical standard terminal boxes
- Fixed ranges, easy to use Ready to use without any settings or adjustments
- Zero/Span compensation on front panel for readjustment of sensor signal or measuring equipment
- True 3-port separation Protection against erroneous measurements due to parasitic voltages or ground loops
- Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage
- Unlimited use with 24 V AC/DC power supply Universally applicable for all measurement and industrial applications
- 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender).
![]() |
![]() |