Main features of the MINI 01 model:

  • Rated current: 150 A AC
  • Output signal: alternating current
  • Transformation ratio: 1,000/1
  • Output via lead and isolated Ø 4 mm male plugs
  • Output protected against voltage surges
Datasheet

Main features of the MINI 02 model:

  • Rated current: 100 A AC
  • Output signal: alternating current
  • Transformation ratio: 1,000/1
  • Output via lead and isolated Ø 4 mm male plugs
  • Output protected against voltage surges
Datasheet

Main features of the MINI 03 model:

  • Rated current: 100 A AC
  • Output signal: AC voltage
  • Output / input ratio: 1mV / A AC
  • Output via lead and isolated Ø 4 mm male plugs
Datasheet

Main features of the MINI 05 model:

  • Rated current: 100 A AC
  • Output signal: AC voltage
  • Output / input ratio: 1 mV / mA AC, 1 mV / AAC
  • Output via lead and isolated Ø 4 mm male plugs
Datasheet

Main features of the MINI 09 model:

  • Rated current: 150 A AC
  • Output signal: DC voltage
  • Output / input ratio: 100 mV DC / A AC
  • Output via lead and isolated Ø 4 mm male plugs
Datasheet

  • Rated current: 200 A AC
  • Ø 16 mm max.
  • Output signal: alternating current
  • Transformation ratio: 1,000/1 (1 mA/A AC)
  • Output via lead and isolated Ø 4 mm male plugs
  • Output protected against voltage surges

Equipped with a high-performance magnetic material and a double winding, the MINI102 clamp offers excellent performance in terms of phase offset and linearity, meeting all the requirements of watt metering applications.

Datasheet

  • Rated current: 200 A AC
  • Ø 16 mm max.
  • Signal de sortie : tension alternative
  • Transformation ratio : 1 mV/A AC
  • Output via lead and isolated Ø 4 mm male plugs

Equipped with a high-performance magnetic material and a double winding, the MINI102 clamp offers excellent performance in terms of phase offset and linearity, meeting all the requirements of watt metering applications.

Datasheet

Main features of the C100 model:

  • Output signal: alternating current
  • Transformation ratio: 1,000/1
  • Output via isolated Ø 4 mm female sockets
Datasheet

Main features of the C102 model:

  • Output signal: alternating current
  • Transformation ratio: 1,000/1
  • Output via isolated Ø 4 mm female sockets
  • Output protected against voltage surges
Datasheet

Main features of the C103 model:

  • Output signal: alternating current
  • Transformation ratio: 1,000/1
  • Output via lead and isolated Ø 4 mm male plugs
  • Output protected against voltage surges
Datasheet

Main features of the C106 model:

  • Output signal: AC voltage
  • Output/input ratio: 1 mV / A AC
  • Output via isolated Ø 4 mm female sockets
Datasheet

Main features of the C107 model:

  • Output signal: AC voltage
  • Output/input ratio: 1 mV / A AC
  • Output via lead and isolated Ø 4 mm male plugs
Datasheet

Main features of the C112 model:

  • Output signal: AC voltage
  • Output/input ratio: 1 mV / A AC
  • Output via isolated Ø 4 mm female sockets
  • Output protected against voltage surges
Datasheet

Main features of the C113 model:

  • Output signal: alternating current
  • Transformation ratio: 1,000/1
  • Output via lead and isolated Ø 4 mm male plugs
  • Output protected against voltage surges
Datasheet

Main features of the C116 model:

  • Output signal: alternating voltage
  • Output / input ratio: 1 mV / A AC
  • Output via isolated Ø 4 mm female sockets
Datasheet

Main features of the C122 model:

  • Output signal: alternating current
  • Transformation ratio: 1,000/5
  • Output via isolated Ø 4 mm female sockets
  • Output protected against voltage surges
Datasheet

Main features of the C148 model:

  • Output signal: alternating current
  • Transformation ratio: 250/5, 500/5 and 1,000/5
  • Output via isolated Ø 4 mm female sockets
  • Output protected against voltage surges
Datasheet

Main features of the C160 model:

  • Output signal: AC voltage
  • Output / input ratio: 100 mV / A AC, 10 mV / A AC, 1 mV / A AC,
  • Output via coaxial cable and isolated male BNC plug
Datasheet

Main features of the D30CN model:

  • Rated current: 2,400 A AC
  • Output signal: alternating current
  • Transformation ratio: 3,000/1
  • Output via lead and isolated Ø 4 mm male plugs
  • Output protected against voltage surges
Datasheet

Main features of the D30N model:

  • Rated current: 2,400 A AC
  • Output signal: alternating current
  • Transformation ratio: 3,000/1
  • Output via isolated Ø 4 mm female sockets
  • Output protected against voltage surges
Datasheet

Main features of the D31N model:

  • Rated current: 1,500 A AC
  • Output signal: alternating current
  • Transformation ratio: 500/1, 1,000/1,1,500/1
  • Output via isolated Ø 4 mm female sockets
  • Output protected against voltage surges
Datasheet

Main features of the D32N model:

  • Rated current: 2,400 A AC
  • Output signal: alternating current
  • Transformation ratio: 1,000/1, 2,000/1, 3,000/1
  • Output via isolated Ø 4 mm female sockets
  • Output protected against voltage surges
Datasheet

Main features of the D33N model:

  • Rated current: 2,400 A AC
  • Output signal: alternating current
  • Transformation ratio: 3,000/5
  • Output via isolated Ø 4 mm female sockets
  • Output protected against voltage surges
Datasheet

Main features of the D34N model:

  • Rated current: 2,400 A AC
  • Output signal: alternating current
  • Transformation ratio: 500/5, 1,000/5,1,500/5
  • Output via isolated Ø 4 mm female sockets
  • Output protected against voltage surges
Datasheet

Main features of the D35N model:

  • Rated current: 2,400 A AC
  • Output signal: alternating current
  • Transformation ratio: 1,000/5, 2,000/5,3,000/5
  • Output via isolated Ø 4 mm female sockets
  • Output protected against voltage surges
Datasheet

Main features of the D36N model:

  • Rated current: 2,400 A AC
  • Output signal: alternating current
  • Transformation ratio: 3,000/3
  • Output via isolated Ø 4 mm female sockets
  • Output protected against voltage surges
Datasheet

Main features of the D37N model:

  • Rated current: 2,000 A AC
  • Output signal: AC voltage
  • Output / input ratio: 100 mV / A AC, 10 mV /A AC, 1 mV / A AC
  • Output via isolated Ø 4 mm female sockets
Datasheet

Main features of the D38N model:

  • Output signal: AC voltage
  • Output / input ratio: 10 mV / A AC, 1 mV / AAC, 0.1 mV / A AC
  • Output via coaxial cable and isolated male BNC plug
Datasheet

  • Current from 10 mA to 100 A AC+DC (140 Apeak)
  • Output signal: 10 mV/A
  • Bandwidth: 1 MHz
  • Switchable filters: 30 kHz, 3 kHz
Datasheet

Main features of the MN08 model:

  • Rated current: 200 A AC
  • Output signal: alternating current
  • Transformation ratio: 1,000/1
  • Output via isolated Ø 4 mm female sockets
Datasheet

Main features of the MN09 model:

  • Rated current: 200 A AC
  • Output signal: Alternating current
  • Transformation ratio: 1,000/1
  • Output via lead and isolated Ø 4 mm male plugs
Datasheet

Main features of the MN10 model:

  • Rated current: 200 A AC
  • Output signal: alternating current
  • Transformation ratio: 1,000/1
  • Output via isolated Ø 4 mm female sockets
  • Output protected against voltage surges
Datasheet

Main features of the MN11 model:

  • Rated current: 200 A AC
  • Output signal: alternating current
  • Transformation ratio: 1,000/1
  • Output via lead and isolated Ø 4 mm male plugs
  • Outputprotected against voltage surges
Datasheet

Main features of the MN12 clamp:

  • Rated current: 200 A AC
  • Output signal: AC voltage
  • Output / input ratio: 10 mV / A AC
  • Output via isolated Ø 4 mm female sockets
Datasheet

Main features of the MN13 model:

  • Rated current: 200 A AC
  • Output signal: AC voltage
  • Rapport sortie/entrée : 10 mV / A AC
  • Output via lead and isolated Ø 4 mm male plugs
  • Outputprotected against voltage surges
Datasheet

Main features of the MN15 model:

  • Rated current: 200 A AC
  • Output signal: AC voltage
  • Output / input ratio: 1 mV / A AC
  • Output via lead and isolated Ø 4 mm male plugs
Datasheet

Main features of the MN21 model:

  • Rated current: 200 A AC
  • Output signal: alternating current
  • Transformation ratio: 1,000/1
  • Output via lead and isolated Ø 4 mm male plugs
  • Outputprotected against voltage surges
Datasheet

Main features of the MN23 model:

  • Rated current: 200 A AC
  • Output signal: AC voltage
  • Output / input ratio: 10 mV / A AC
  • Output via lead and isolated Ø 4 mm male plugs
Datasheet

Main features of the MN38 model:

  • Rated current: 200 A AC
  • Output signal: AC voltage
  • Output / input ratio: 100 mV / A AC, 10 mV /A AC
  • Output via isolated Ø 4 mm female sockets
Datasheet

Main features of the MN39 model:

  • Rated current: 200 A AC
  • Output signal: AC voltage
  • Output / input ratio: 100 mV / A AC, 10 mV /A AC
  • Output via lead and isolated Ø 4 mm male plugs
Datasheet

Main features of the MN60 model:

  • Output signal: AC voltage
  • Output / input ratio: 100 mV / A AC, 10 mV /A AC
  • Output via coaxial cable and isolated BNC male plug
Datasheet

Main features of the MN71 model:

  • Rated current: 10 A AC
  • Output signal: AC voltage
  • Output / input ratio: 100 mV / A AC
  • Output via lead and isolated Ø 4 mm male plugs
Datasheet

Main features of the MN88 model:

  • Rated current: 200 A AC
  • Output signal: DC voltage
  • Output / input ratio: 100 mV DC/ A AC
  • Output via isolated Ø 4 mm female sockets
Datasheet

Main features of the MN89 model:

  • Rated voltage: 200 A AC
  • Output signal: DC voltage
  • Output / input ratio: 100 mV DC/ A AC
  • Output via lead and isolated Ø 4 mm male plugs
Datasheet

Main features of the PAC10 model:

  • Rated current: 400 A AC/600 A DC
  • Output signal: DC and AC voltage
  • Output / input ratio: 1 mV / A
  • Output via lead and isolated Ø 4 mm male plugs
Datasheet

Main features of the PAC16 clamp:

  • Rated current: 40 AAC/60ADC - 400 AAC/600 ADC
  • Output signal: DC and AC voltage
  • Output / input ratio: 10 mV / A, 1 mV / A
  • Output via lead and isolated Ø 4 mm male plugs
Datasheet

Main features of the PAC17 clamp:

  • Rated current: 40 AAC/60 ADC - 400 AAC/600 ADC
  • Output signal: DC and AC voltage
  • Output / input ratio: 10 mV / A, 1 mV / A
  • Output via coaxial cable and isolated BNC male plug
Datasheet

Main features of the PAC25 model:

  • Rated current: 1,000 A AC/1,400 A DC
  • Output signal: DC and AC voltage
  • Output / input ratio: 1 mV / A
  • Output via lead and isolated Ø 4 mm male plugs
Datasheet

Main features of the PAC26 model:

  • Rated current: 100 AAC/150 ADC - 1,000 AAC/1,400 ADC
  • Output signal: DC and AC voltage
  • Output / input ratio: 10 mV / A, 1 mV / A
  • Output via lead and isolated Ø 4 mm male plugs
Datasheet

Main features of the PAC27 model:

  • Rated current: 100 AAC/150 ADC - 1,000 A AC/1,400 A DC
  • Output signal: DC and AC voltage
  • Output / input ratio: 10 mV / A, 1 mV / A
  • Output via coaxial cable and isolated BNC male plug
Datasheet

Main features of the Y1N model:

  • Rated current: 600 A AC
  • Output signal: alternating current
  • Transformation ratio: 1,000/1
  • Output via lead and isolated Ø 4 mm male plugs
  • Outputprotected against voltage surges
Datasheet

Main features of the Y2N model:

  • Rated current: 600 A AC
  • Output signal: alternating current
  • Transformation ratio: 1,000/1
  • Output via lead and isolated Ø 4 mm male plugs
  • Outputprotected against voltage surges
Datasheet

Main features of the Y3N model:

  • Rated current: 600 A AC
  • Output signal: alternating current
  • Transformation ratio: 100/1
  • Output via lead and isolated Ø 4 mm male plugs
Datasheet

Main features of the Y4N model:

  • Rated current: 600 A AC
  • Output signal: DC voltage
  • Output / input ratio: 100 mV DC / A AC
  • Output via lead and isolated Ø 4 mm male plugs
Datasheet

Main features of the Y7N model:

  • Output signal: AC voltage
  • Output / input ratio: 1 mV / A AC
  • Output via coaxial cable and isolated BNC male plug
Datasheet

  • Leakage current differential measurements (from 500 μA) when searching for faults
  • Measuring AC currents up to 400 A
  • Jaws: gap: 112mm . Capacity with jaws open: 250 mm. Clamping capacity: cable with a maximum diameter of 115 mm
  • Current direction: arrow , visible on the side of the clamp, indicating the current’s direction. The current is deemed to be circulating in the positive direction when it flows from the current’s generator to the current’s consumer.
  • Sizes: 2. - Measurement current: 4 A: output 1 mV/mA. - Measurement current: 400 A: output 1 mV/A.
  • Output: voltage output, via a 1.5m-long cable moulded into the clamp and terminating in two 90° elbow male safety plugs
Datasheet