Showing all 18 results

  • 3 digit LED display
  • Recording min./max. temerature
  • Measuring ranges from -20…200°C
  • Contact output DC PNP, max. 200 mA
  • Analog output: 4…20 mA, 3-wires 0…10 V, 3-wires 0...20 mA, 3-wires
Datasheet

  • Case aluminium, epoxy resin coated
  • Ingress protection IP 65, NEMA 4
  • Ambient temperature -40 ... +85 °C
  • 1 switch point, SPDT or DPDT with a high contact rating of up to 15 A / AC 220 V
  • Capillary up to 10 m



Datasheet
User Manual

  • Case aluminium, epoxy resin coated
  • Ingress protection IP 65, NEMA 4
  • Ambient temperature -40 ... +85 °C
  • 1 switch point, SPDT or DPDT with a high contact rating of up to 15 A/AC 220 V
  • Capillary up to 10 m



Datasheet
User Manual

  • Easily-readable, robust display
  • Intuitive and fast setup
  • Easy and flexible mounting configurations
Datasheet

  • No power supply needed for switching of electrical loads
  • Setting ranges from -30 ... +70°C up to 0 ... 600 °C
  • Robust switch enclosure from aluminium alloy, IP 66, NEMA 4X
  • 1 or 2 independent set points, SPDT or DPDT, high switching power up to AC 250 V, 20 A
  • Remote mounting with capillary ≤ 10 m



Datasheet
User Manual

  • Electropolished case
  • Ingress protection IP 65, NEMA 4
  • Ambient temperature -40 ... +85 °C
  • 1 or 2 independent switch points, high contact rating up to 15 A / AC 220 V
  • Directly connected or via capillary (up to 10 m capillary)




Datasheet
User Manual

  • Case from AISI 316 (1.4401)
  • Ingress protection IP 66, NEMA 4
  • Ambient temperature -40 ... +85 °C
  • 1 switch point, SPDT, up to 5 A/AC 220 V
  • Directly connected or via capillary (up to 10 m capillary



Datasheet
User Manual

  • No power supply needed for switching of electrical loads
  • Setting ranges from -15 ... +20 °C to 180 ... 250 °C
  • Repeatability of the set point ≤ 1% span
  • 1 set point, SPDT, high switching power up to AC 250 V, 5 A
  • Direct mounting or remote mounting with capillary ≤ 10 m



Datasheet
User Manual

Control input signal0..10V=
Temp. setpoint range1 ... 10 oC
Output Signal0..10V: Input/Temp.
Ambient temperature15 ... 15 oC
Switch function/capacitySPDT 250 Vac Microswitch / 8A
Reset functionreset inside
Thermostat applicationfrost protection thermostat, 2-phases
Mounting placeair duct
IP classIP40
Power supply24 Vac | 7 VA 
Temperature elementcapillary
Setpoint deviceinside
Additional descriptionThe 0-10V output signal is the maximum of the input signal and the temperature value (10-0 degrees C = 0-10V)
Datasheet

Housing materialPolycarbonate and ABS
Ambient temperature-20 ... 55 oC
Switch function/capacitySPDT 24..250 Vac, 15(8)A
Thermostat applicationfrost protection thermostat
Mounting placeair duct
Setpoint devicescrew
Temp. setpoint range-8 ... 8 oC
Differential fixed2 K
IP classIP65
Datasheet

Electrical connectionM20x1,5
IP classIP54
Housing materialPA, ABS, PMMA
Ambient temperature0 ... 80 oC
Switch function/capacitymax: 230 Vac, 12 (2,5) A min: 24 Vac/dc, 100 mA
Capillary tube length2 m
CertificatesCE, UL, PED, DIN EN 14597
Thermostat applicationstrap-on thermostat
Reset functionautomatic reset
Setpoint devicescrew
Mounting placestrap on pipe
Differential fixed10 K
Datasheet

Housing materialglass fibre reinforced ABS
Ambient temperature-20 ... 70 oC
Thermostat applicationroom thermostat, industrial
Mounting placeinternal wall
Setpoint deviceknob
Datasheet

IP classIP54
Housing materialAluminium diecasting with plastic cover
Ambient temperature0 ... 80 oC
Switch function/capacitySPST 230 Vac, 10 A
Immersion depth150 mm
CertificatesTUEV-approval STB895
Thermostat applicationimmersion tube thermostat
Reset functionreset button
Setpoint deviceinside
Temp. setpoint range60 ... 130 oC
Mounting placein pipe
Immersion well materialred brass, nickel plated
Immersion well threadR1/2"
Max. perm. temp. at sensor150 oC

Datasheet

IP classIP54
Housing materialAluminium diecasting with plastic cover
Ambient temperature0 ... 80 oC
Switch function/capacitysafety control switch SPDT 230 Vac, 10 A; shut-off temperature switch SPST 230 Vac, 10 A
Immersion depth150 mm
CertificatesTUEV-approval TR/STB 900
Thermostat applicationimmersion tube therm. + controller
Reset functionreset button
Setpoint deviceinside+outside
Temp. setpoint range30/30 ... 110/110 oC
Mounting placein pipe
Immersion well materialred brass, nickel plated
Immersion well threadR1/2"
Max. perm. temp. at sensor130 oC
Additional descriptionSafety control switching differential approx. 4% of setpoint value. Shut-off temperature: 30..110 oC adjustable.
Datasheet

IP classIP54
Housing materialAluminium diecasting with plastic cover
Ambient temperature0 ... 80 oC
Switch function/capacitySPDT 230 Vac, 10 A
CertificatesTUEV-approval STW(STB)894 S
Thermostat applicationimmersion tube thermostat
Reset functionautomatic reset
Setpoint deviceinside
Temp. setpoint range20 ... 150 oC
Mounting placein pipe
Immersion depth150 mm
Immersion well materialred brass, nickel plated
Immersion well threadR1/2"
Max. perm. temp. at sensor175 oC
Additional descriptionFixed switching differential approx. 4% of setpoint value.
Datasheet

IP classIP54
Housing materialAluminium diecasting with plastic cover
Ambient temperature0 ... 80 oC
Switch function/capacitysafety control switch SPDT 230 Vac, 10 A; shut-off temperature switch SPST 230 Vac, 10 A
Immersion depth150 mm
CertificatesTUEV-approval TW/STB 904
Thermostat applicationimmersion tube therm. + monitor
Reset functionreset button
Setpoint device2x inside
Temp. setpoint range30/30 ... 110/110 oC
Mounting placein pipe
Immersion well materialred brass, nickel plated
Immersion well threadR1/2"
Max. perm. temp. at sensor130 oC
Additional descriptionSafety control switching differential approx. 3..4% of setpoint value. Shut-off temperature: 30..110 oC adjustable.

Datasheet

IP classIP54
Housing materialAluminium diecasting with plastic cover
Ambient temperature0 ... 80 oC
Switch function/capacitySPDT 230 Vac, 10 A
Immersion depth150 mm
CertificatesTUEV-approval TW 89 207
Thermostat applicationimmersion tube thermostat
Reset functionautomatic reset
Setpoint deviceinside
Temp. setpoint range20 ... 150 oC
Mounting placein pipe
Immersion well materialred brass, nickel plated
Immersion well threadR1/2"
Max. perm. temp. at sensor175 oC
Datasheet

IP classIP54
Housing materialAluminium diecasting with plastic cover
Ambient temperature0 ... 80 oC
Switch function/capacitysafety control switch SPDT 230 Vac, 10 A; shut-off temperature switch SPST 230 Vac, 10 A
Immersion depth150 mm
CertificatesTUEV-approval TR/STB 900
Thermostat applicationimmersion tube therm. + controller
Reset functionreset button
Setpoint deviceinside+outside
Temp. setpoint range30/30 ... 110/110 oC
Mounting placein pipe
Immersion well materialred brass, nickel plated
Immersion well threadR1/2"
Max. perm. temp. at sensor130 oC
Additional descriptionSafety control switching differential approx. 4% of setpoint value. Shut-off temperature: 30..110 oC adjustable.
Datasheet

Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.
This site is registered on wpml.org as a development site.