  • 3 digit LED display
  • Recording min./max. temerature
  • Measuring ranges from -20
200°C
  • Contact output DC PNP, max. 200 mA
  • Analog output: 4
20 mA, 3-wires 0
10 V, 3-wires 0...20 mA, 3-wires
Datasheet

  • Case aluminium, epoxy resin coated
  • Ingress protection IP 65, NEMA 4
  • Ambient temperature -40 ... +85 °C
  • 1 switch point, SPDT or DPDT with a high contact rating of up to 15 A / AC 220 V
  • Capillary up to 10 m



Datasheet
User Manual

  • Case aluminium, epoxy resin coated
  • Ingress protection IP 65, NEMA 4
  • Ambient temperature -40 ... +85 °C
  • 1 switch point, SPDT or DPDT with a high contact rating of up to 15 A/AC 220 V
  • Capillary up to 10 m



Datasheet
User Manual

  • Easily-readable, robust display
  • Intuitive and fast setup
  • Easy and flexible mounting configurations
Datasheet

  • No power supply needed for switching of electrical loads
  • Setting ranges from -30 ... +70°C up to 0 ... 600 °C
  • Robust switch enclosure from aluminium alloy, IP 66, NEMA 4X
  • 1 or 2 independent set points, SPDT or DPDT, high switching power up to AC 250 V, 20 A
  • Remote mounting with capillary ≀ 10 m



Datasheet
User Manual

  • Electropolished case
  • Ingress protection IP 65, NEMA 4
  • Ambient temperature -40 ... +85 °C
  • 1 or 2 independent switch points, high contact rating up to 15 A / AC 220 V
  • Directly connected or via capillary (up to 10 m capillary)




Datasheet
User Manual

  • Case from AISI 316 (1.4401)
  • Ingress protection IP 66, NEMA 4
  • Ambient temperature -40 ... +85 °C
  • 1 switch point, SPDT, up to 5 A/AC 220 V
  • Directly connected or via capillary (up to 10 m capillary



Datasheet
User Manual

  • No power supply needed for switching of electrical loads
  • Setting ranges from -15 ... +20 °C to 180 ... 250 °C
  • Repeatability of the set point ≀ 1% span
  • 1 set point, SPDT, high switching power up to AC 250 V, 5 A
  • Direct mounting or remote mounting with capillary ≀ 10 m



Datasheet
User Manual

Control input signal 0..10V=
Temp. setpoint range 1 ... 10 oC
Output Signal 0..10V: Input/Temp.
Ambient temperature 15 ... 15 oC
Switch function/capacity SPDT 250 Vac Microswitch / 8A
Reset function reset inside
Thermostat application frost protection thermostat, 2-phases
Mounting place air duct
IP class IP40
Power supply 24 Vac | 7 VA 
Temperature element capillary
Setpoint device inside
Additional description The 0-10V output signal is the maximum of the input signal and the temperature value (10-0 degrees C = 0-10V)
Datasheet

Housing material Polycarbonate and ABS
Ambient temperature -20 ... 55 oC
Switch function/capacity SPDT 24..250 Vac, 15(8)A
Thermostat application frost protection thermostat
Mounting place air duct
Setpoint device screw
Temp. setpoint range -8 ... 8 oC
Differential fixed 2 K
IP class IP65