A high precision Druck pressure controller, designed for test bench, bench top and rack mount calibration, and automated test applications. Modularity increases user flexibility, reduces downtime and lowers overall cost of ownership. Additional Features: - Dual channel pressure controller chassis - Aeronautical option enabling full control in aeronautical units - With two PACE CM3 control modules fitted in the PACE6000 can be used in single, auto-ranging or simultaneous dual pressure control mode* - No module pressure range ratio limit

Datasheet

A high precision Druck pressure controller, designed for test bench, bench top and rack mount calibration, and automated test applications. Modularity increases user flexibility, reduces downtime and lowers overall cost of ownership. Features: - Market leading speed to set point, pressure stability in large volumes - No overshoot of set point - Up to 210 bar (3000 psi/21 MPa) gauge and absolute - Precision to 0.001% FS over calibrated temperature range - Long-term stability to 0.0025% FS per annum - 28 selectable pressure units and 4 user defined units

Datasheet

  • Pressure ranges: 1 ... 1,000 mbar (0.01 ... 14.5 psi)
  • Accuracy: to 0.1 % FS
  • Integrated, automatic pressure generation
  • Portable, also usable without power supply unit due to Li-Ion battery
  • Simple operation
Datasheet
User Manual

  • Pressure ranges: -1 ... 210 bar [-15 ... 3,045 psi]
  • Control speed < 4 seconds for 25 % FS steps
  • Accuracy: to 0.02 % FS
  • PACE emulation
Datasheet
User Manual

  • Pressure ranges: -1 ... 210 bar (-15 ... 3,045 psi)
  • Control speed 10 s
  • Control stability < 0.005 % FS
  • Accuracy to 0.02 % IS (IntelliScale)
  • Precision 0.008 % FS
Datasheet
User Manual

  • Pressure ranges: 0 ... 700 bar (0 ... 10,000 psi)
  • Control speed 30 s
  • Control stability 0.008 % FS
  • Accuracy down to 0.01 % IS (IntelliScale)
Datasheet
User Manual

  • Pressure ranges: -1 ... 210 bar (-15 ... 3,045 psi)
  • Control speed 15 s
  • Control stability < 0.003 % FS (typical 0.001 % FS)
  • Accuracy down to 0.01 % IS (IntelliScale)
  • Precision 0.004 % FS
Datasheet
User Manual

  • Pressure ranges: -1 ... 400 bar [-15 ... 6,000 psi] in the pressure types positive and negative gauge pressure al well as absolute pressure
  • Up to three integrated, interchangeable reference pressure sensors
  • Control stability 0.002 % of the span
  • Accuracy down to 0.008 % IS (IntelliScale)
  • Precision 0.004 % FS
Datasheet
User Manual

  • Pressure ranges: 75 ... 10,000 psi up to 290 ... 23,000 psi (5 ... 700 bar up to 20 ... 1,600 bar)
  • Pressure medium: Hydraulic oil or water
  • Control stability: 0.005 % of FS
  • Accuracy: to 0.01 % of FS
  • Interchangeable reference pressure sensors
Datasheet
User Manual

  • Interchangeable reference sensors that can be changed via the front
  • Large colour touchscreen with all necessary information
  • Control stability 0.001 % of span
  • Accuracy up to 0.009 % IS-50 (IntelliScale)
Datasheet

  • Fully automatic calibrator with built-in pump and controller
  • Switchable internal pressure modules for expandable ranges
  • Accuracy (1 year ) of 0.02% FS
  • Less than 4 lbs (1.8 kg) for handheld operation
  • Source pressure, measure pressure and electrical
  • 4 channels
  • Optional HART-communications
  • Optional data logging and task documentating
  • USB, Wi-Fi and Bluetooth communications
Datasheet
User Manual
User Manual

  • Automated and self-contained pressure generation and control from -0.9 bar to 70 bar (1,000) psi
  • Standard accuracy to 0.02% of Span*
  • Optional precision accuracy models up to 0.01% of Span
  • Two removable internal pressure modules for multi-range selection
  • Control stability to 0.003% of Span
  • Portable, designed for use in the field and in the lab
  • Ability to measure two external pressure modules
  • Wi-Fi, Bluetooth, USB and Ethernet communication
  • HART and profibus communication
  • Data logging and task management
  • Patented electric pump technology and improved speed
Datasheet
User Manual
User Manual

  • Automated pressure generation and control to 10,000 psi (700 Bar)
  • Accuracy to 0.01%FS
  • Dual-range manual or auto select
  • Control stability 0.005%FS
  • Portable - designed for use in the field and in the lab
  • Control by optional external pressure modules
  • Supports two external pressure modules
  • Wi-Fi, LAN, Bluetooth, USB and Ethernet communication
  • Full HART field communicator
  • HART and PROFIBUS communication
  • Data logging and task management
  • Patented electric pump technology
Datasheet

  • Pressure ranges from vacuum to 200 bar (3000 psi)
  • Removable interchangeable intelligent sensors
  • Precision accuracy of 0.005% of reading +0.005% of full scale
  • Standalone solution up to 70 bar, no gas bottle required when used with the electric pump
  • Standard model accuracy of 0.02% of full scale
  • External pressure modules to 200 bar (3000 psi)
  • WiFi enabled communications
  • Fully temperature compensated accuracy from 0°C to 50°C
  • HART communication and Profibus PA
  • Large 7” color touch screen display
  • Control stability of 0.003% FS
  • Built-in barometer
  • Easy-to-use icon based user interface
Datasheet
User Manual

  • Multicalibration of up to 7 test items possible
  • Templates for the creation of calibration certificates and logger protocols
  • Flexibility through individual settings
  • Simple operation and set-up of the software
  • SQL database independent from Microsoft® Access®
Software Download
User Manual

  • Individuelle Prüfeinrichtung für Werkstatt, Prozess und Service
  • Automatische Druckregler PACE 5000/ PACE 6000 integriert
  • Für wählbare Messbereiche von -1 … 0 … +210 bar
  • Automatische Vorgabe der Prüfpunkte, Rampen über Touchscreen
  • Genauigkeit: 0,05 bis zu 0,0015 % FS
  • Großes TFT-Touchscreen
  • Eingebaute N2-Stickstoffflasche mit präzisem manuellen Druckregler (auf Wunsch externe Druckflasche)
  • Eingebaute Vakuumpumpe für Unterdruck / Absolutdruck (auf Wunsch auch ohne Vakuumpumpe)
  • Eingebaut analog Manometer für Vakuum, Überdruck und Flaschendruck
  • Externe Nachfüllung der N2_Stickstoffflasche über Minimess
  • Prüflingsanschluss über Minimess-Schnellkupplung
  • Betrieb an Netz 230 V AC 50 Hz oder Batterie-Betrieb
  • Robuster abschließbarer Alukoffer
Datenblatt