Showing 1–10 of 16 results

  • CAT IV 600V / CAT III 1,000V
  • TRMS measurements
  • Large 6,000-count backlit display (digit height: 8 mm)
  • 61-segment bargraph
  • Compact casing with built-in shockproof protection
  • Double OFF position
  • NCV (no-contact voltage detection)
  • VLow Z low-impedance voltage measurement to avoid stray voltages.
  • Measurement up to 1,000 V
  • 60mV range
  • AC or DC current measurement up to 600 A with current clamp (1mv/A AC or DC) with direct reading of the measurement in Amperes
  • IP54
  • Compatible with the multi-function mounting accessory
The "C.A 5231 KIT" reference comprises a C.A 5231 multimeter accompanied by a MINI 03 100 AAC current clamp.
Datasheet

  • CAT IV 600V
  • TRMS measurements
  • Large 6,000-count backlit display (digits 8 mm high)
  • 61-segment bargraph
  • Double OFF position
  • No-contact voltage detection  (NCV)
  • VLow Z low-impedance voltage measurement to avoid stray voltages.
  • Min, MAX and RELative functions
  • Measurement up to 600 V
  • AC or DC current measurement up to 10 A
  • Frequency measurement
  • Temperature measurement
  • Capacitance measurement
  • 60 mV range
  • Compact IP54 casing with built-in shockproof protection
  • Compatible with the multi-function mounting accessory
Datasheet

  • CAT IV 600V / CAT III 1,000V
  • TRMS measurements
  • Bi-mode double 6,000-count backlit display and 61+2-segment bargraph (full scale / central zero)
  • Auto AC/DC selection
  • Automatic or manual range selection
  • VLowZ low-impedance voltage measurement with low-pass filter
  • 1,000 V
  • 10 A
  • Resistance / audible continuity
  • Temperature
  • Capacitance
  • Max / Min storage
  • 3-year warranty
Datasheet

  • TRMS AC+DC measurement of voltage and current
  • 12-bit converter
  • 5 measurements / second
  • CAT IV 600V / CAT III 1,000V
  • IP54
  • Double 6,000-count backlit display and 61+2-segment bargraph
  • Automatic or manual range selection
  • VLowZ low-impedance voltage measurement with low-pass filter
  • 1,000 V / 10 A
  • 10 ”V resolution
  • Current from 1 ”A
  • Measurement of ionization currents
  • Min / Max measurements
  • Resistance / audible continuity
  • Capacitance
  • 3-year warranty
Datasheet

  • TRMS AC+DC measurement of voltage and current
  • 12-bit converter
  • 5 measurements / second
  • CAT IV 600V / CAT III 1000V
  • IP54
  • Double 6,000-count backlit display
  • Bi-mode bargraph with  61+2 segments (full scale/central zero)
  • Automatic or manual range selection
  • VLowZ low-impedance voltage measurement with low-pass filter
  • 1,000 V / 10 A
  • 10 ”V resolution
  • Current from 1 ”A
  • Measurement of ionization currents
  • Resistance / audible continuity
  • Temperature / Capacitance
  • ÎŒA range for ionization current measurement
  • Min / MAX (100 ms)
  • Peak+ / Peak- (1 ms)
  • Differential measurements (&Delta ;X) et RELative (&Delta ;X/X%)
  • 3-year warranty
Datasheet

FLASHMETER is a compact DMM capable of carrying out TRMS voltage measurements up to 600V as well as resistance measurements automatically under autorange, just connecting input terminals. It was designed in compliance with safety standards IEC/EN61010-1 with double insulation protection under CAT IV 600V. FLASHMETER is provided with a white light torch, a probe to detect AC voltage without contact and is water resistant according to IP67 .

Datasheet

Digital multimeter with integrated AC/DC 60A clamp meter Model HT12 is a super compact digital multimeter capable o carrying out measurements of Voltage up to 600V, AC/ DC current up to 60A with integrated clamp sensor and complementary functions of Resistance, Continuity test and Frequency. This device has been designed in compliance with safety standard IEC/EN61010-1 with double protective insulation in CAT III 300V, CAT II 600V. Further functions are Data HOLD to freeze data on the display and the Auto Power OFF function after 10 minutes’ idling, in order to preserve the internal battery. The device is housed in a protective case which is also used to rewind the test leads.

Datasheet

HT38 is essential to identify the circuit breaker protecting a given socket on a panel board without having to dissect it. HT38 includes a signal generator (HT38T) to be connected to the socket under test and a signal receiver (HT38R) capable of "exploring" all RCCBs of the panel board.

Datasheet

  • TRMS
  • AC/DC voltage 1000V
  • AC/DC current 10A
  • Frequency
  • Resistance and continuity test with buzzer
  • Duty Cycle (%)
  • Backlight
  • Autorange
  • Auto Power OFF
  • Data HOLD
  • Relative measurement
  • Diode test
  • Protection category CAT IV 600V
  • Weight in grams (batteries included)
  • Measuring spots 6000
  • Power supply 1x 9V 6F22
  • Size (L x W x H) 190x94x48
  • Normative
    • IEC/EN 61010-1
    • CE MARK
Datasheet

  • TRMS
  • AC/DC voltage 1000V
  • AC/DC current 10A / Reading 4-20mA%
  • Frequency
  • Resistance and continuity test with buzzer
  • Capacity
  • Duty Cycle (%)
  • Temperature with K-type probe
  • Backlight
  • Autorange
  • Auto Power OFF
  • Data HOLD
  • Relative measurement
  • Diode test
  • Protection category CAT IV 600V
  • Weight in grams (batteries included) 460
  • Measuring spots 60.000
  • Power supply 1x 9V 6F22
  • Size (L x W x H) 190x94x48
  • Normative
    • IEC/EN 61010-1
    • CE MARK
Datasheet

Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem EinverstÀndnis aus.