• Measuring ranges 0 ... 100 N to 0 ... 36 kN
  • Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
  • Piston stroke ≤ 0.5 mm
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet
User Manual

  • Measuring ranges 0 ... 100 N to 0 ... 36 kN
  • Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
  • Piston stroke ≤ 0.5 mm
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet
User Manual

  • Measuring ranges 0 ... 1.1 kN to 0 ... 180 kN
  • Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
  • Piston stroke ≤ 0.5 mm, force introduction as total clamping force
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet

  • Measuring ranges 0 ... 160 N to 0 ... 60 kN
  • Relative linearity error ±1.0 ... ±1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor
  • Piston stroke ≤ 0.5 mm
  • Operates without supply voltage
  • 5-year leak-tightness warranty
Datasheet
User Manual

  • Measuring ranges 0 ... 2.5 kN to 0 ... 470 kN
  • Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
  • Piston stroke ≤ 0.5 mm, force introduction as total clamping force
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet

  • Measuring ranges 0 ... 320 N to 0 ... 120 kN
  • Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
  • Piston stroke ≤ 0.5 mm
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet
User Manual

  • Measuring ranges 0 ... 320 N to 0 ... 120 kN
  • Flattened case for stable measurement
  • Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet
User Manual

  • Measuring ranges 0 ... 6 kN to 0 ... 1,000 kN
  • Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
  • Piston stroke ≤ 0.5 mm, force introduction as total clamping force
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet

  • Measuring ranges 0 ... 4 kN to 0 ... 400 kN
  • Relative linearity error ±1.0 ... 1.6 % with analogue pressure gauge, ±0.5 % with digital pressure gauge or pressure sensor1)
  • Piston stroke ≤ 0.8 mm
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet
User Manual

  • Measuring ranges 0 ... 2 kN to 0 ... 480 kN
  • Relative linearity error ±1.0 ... 1.6 % with analogue pressure gauge, ±0.5 % with digital pressure gauge or pressure sensor1)
  • Piston stroke ≤ 0.5 mm
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet
User Manual

  • Measuring ranges 0 ... 1.2 kN to 0 ... 500 kN
  • Flattened case for stable measurement
  • Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet
User Manual

  • Measuring ranges 0 ... 6 kN to 0 ... 850 kN
  • Relative linearity error ±1.0 ... 1.6 % with analogue pressure gauge, ±0.5 % with digital pressure gauge or pressure sensor1)
  • Piston stroke ≤ 0.5 mm
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet

  • Measuring ranges 0 ... 5 t to 0 ... 30 t
  • 1,000 intervals per OIML R60 Class C
  • Measuring element from stainless steel
  • Hermetically sealed and welded, ingress protection IP68
Datasheet
User Manual

  • Measuring ranges 0 ... 1 kN up to 0 ... 1,000 kN
  • For compression force measurements
  • Simple force introduction, easy installation
  • Protection class IP67
  • Relative linearity error 0.3 % Fnom (0.1 % Fnom optional)
Datasheet

  • Measuring ranges 0 ... 10 N up to 0 ... 5,000 N
  • Ease of force input, easy installation
  • Compact and small dimensions, low installation height
  • Protection class IP65
  • Relative linearity error 1 % Fnom
Datasheet

  • Measuring ranges 0 … 1 kN up to 0 ... 500 kN
  • Simple force introduction
  • Compact small dimensions
  • Protection class IP65
  • Relative linearity error 1 % Fnom
Datasheet

  • Measuring ranges 0 ... 0.02 kN to 0 ... 2,200 kN (0 ... 5 lbs to 0 ... 500,000 lbs)
  • Robust version
  • Material: Stainless steel
  • Ingress protection as of IP66
  • Relative linearity error as of 0.1 % Fnom
Datasheet

  • Measuring ranges 0 ... 7.5 t to 0 ... 300 t
  • For compression forces
  • Ingress protection IP68, hermetically sealed
  • Relative linearity error from 0.0166 % Fnom
Datasheet

  • Measuring ranges 0 ... 280 kN to 0 ... 2,060 kN
  • Insensitive to lateral forces
  • Stainless steel version (corrosion-resistant)
  • Integrated amplifier
  • High long-term stability, high shock and vibration resistance, good reproducibility
Datasheet

  • Measuring ranges 0 ... 2.5 kN to 0... 300 kN
  • Relative linearity error 0.1 % Fnom
  • Stainless steel version, completely welded
  • Low installation height, easy to install
  • Ingress protection IP67
Datasheet
User Manual

  • Measuring ranges 0 ... 50 N to 0 ... 1,000 N
  • Relative linearity error 1 % Fnom
  • Stainless steel or aluminium version
  • Low installation height, easy to install
  • Ingress protection IP64
Datenblatt
Bedienungsanleitung

  • Measuring ranges 0 ... 50 N to 0 ... 5 kN
  • Relative linearity error 0.5 % Fnom
  • Material: Stainless steel
  • Low installation height, easy to install
  • Ingress protection IP65
Datasheet
User Manual

  • Measuring ranges 0 ... 200 N to 0 ... 100 kN
  • Relative linearity error 0.5 % Fnom
  • Stainless steel version
  • Low installation height, easy to install
  • Ingress protection IP66
Datasheet
User Manual

  • Measuring range from 1 t
  • Relative linearity error ±0.15 % Fnom
  • Redundant output signal for safety applications
  • Low installation height, easy to install
  • Ingress protection: IP67
Datasheet
User Manual

  • Measuring ranges 0 ... 10 t to 0 ... 50 t
  • Relative linearity error 0.03 % Fnom
  • Material: Stainless steel version, IP67
  • Self-centring rocker pins with dual spherical force introduction
  • Adapter plates available
Datasheet

Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.