- Measurement of insulation up to 1000VDC
- Open-circuit voltage and short-circuit current Voc/Isc up to 1000V/15A
- Continuity of protective conductor with 200mA
![]() |
Measurement category | CAT III 1500V DC / CAT III 1000V AC |
AC TRMS voltage measurement | 3 ÷ 1000V |
DC voltage measurement | 3 ÷ 1500V |
Insulation resistance | 250, 500, 1000, 1500V |
GFL function to locate the fault position in the string | |
Measurement of polarization index P.I. | |
Dielectric absorption ratio D.A.R | |
Continuity of protective conductors with 200mA | |
Size (LxWxH) (mm) | 235 x 165 x 75mm |
Weight | 1.2kg |
![]() |
![]() |
![]() |
- Measurement of I-V Curve of one or more modules or of one whole string up to 1000V/15A
- Measurement of open-circuit voltage and short-circuit current Voc/Isc
- Database of 30.000 selectable photovoltaic modules
![]() |
- Measurement of I-V Curve of one or more modules or of one whole string up to 1500V/15A
- Measurement of open-circuit voltage and short-circuit current Voc/Isc
- Database of 30.000 selectable photovoltaic modules
![]() |
- Measurement of efficiency of a single-phase photovoltaic system
- Measurement of I-V Curve of a module or of a string up to 1500V/10A - 1000V/15A
- Measurement of open-circuit voltage of a module or of a string (VOC) 1500V
- Measurement of short-circuit current of a module or of a string (ISC) 15A
![]() |
- New touchscreen interface
- Verification of the efficiency of the photovoltaic system
- Power quality Analysis with voltage Fast Transient (5µs) measurement
![]() |
- Contemporary analysis of 3 strings
- Compatible with SOLAR300N and SOLAR I-V
- Integrated rechargeable battery
![]() |
Remote unit for recording irradiation and temperature
- Real-time display of irradiation and temperature values
- Setting up to 3 irradiation probes
- Use with pyranometers and reference cells
- Connection to Master units via USB or radio frequency connection RF
- Synchronization with master unit when starting testing/recording.
- Measurement of the tilting angle of PV panels
- Magnetics on the back side of meter
![]() |