RIH – Insulation monitoring


  • Insulation monitor for medical locations and hospital use
  • Continuous monitoring of insulation towards earth in medical IT systems
  • Suitable for operation with Iso TV insulation transformer
  • Monitoring of insulation values, transformer temperature, current, voltage, frequency and power
  • Programmable alarm and pre-alarm thresholds for insulation, temperature and power
  • LCD display with 7 measurement pages and LED alarm indications
  • RS485 communication, JBUS / MODBUS compatible
  • 4-DIN-module housing for 35 mm DIN rail mounting with IP54 front frame
Datasheet

Iso D4-Zs

Insulation monitor for hospital use, 4 DIN modules

Type Insulation monitor for medical locations and hospital use
Format 4 DIN modules according to DIN 43880
Application Continuous monitoring of insulation towards earth in medical IT systems
Reference standards EN / IEC 61557-8, Attachment A and B; field of application IEC 60364-7-710
Connection Insulation transformer Iso TV, NT699
Network voltage 230 V
Rated frequency 50 Hz
Working frequency 47…63 Hz
Insulation measuring circuit current ≤ 100 µA
Temperature sensor Pt100, 2-wire resistance bulb
Current input Via CT / 5 A current transformer
Rated burden current input ≤ 0.5 VA
Input impedance > 100 kΩ
Measuring voltage < 15 V
Display LCD, 2 lines × 8 digits, digit height 5 mm
Measurement display 7 display pages for insulation values, transformer temperature, voltage, frequency, current, active and apparent power
Programmable parameters CT ratio, transformer power, measurement quantity, alarm and pre-alarm values, hysteresis, delay and RS485 parameters
Selectable transformer power 1.5 / 2.5 / 3 / 4 / 5 / 6.3 / 7.5 / 8 / 10 kVA
Insulation alarm 50…500 kΩ
Insulation pre-alarm Alarm…500 kΩ
Temperature alarm 60…150 °C
Power alarm 50…100 % Pn
Alarm hysteresis 0…99 %
Alarm delay 0…99 s
RS485 communication RS485, 3-wire, serial asynchronous, JBUS / MODBUS compatible
RS485 address 1…255
Baud rate 1,200 / 2,400 / 4,800 / 9,600 / 19,200 bit/s
Max. bus length 1200 m
Max. devices on the bus 32, up to 255 with RS485 repeater
Outputs Insulation alarm, temperature / power alarm and output for Iso QZ remote repeater panel
Contact rating alarm outputs 230 VAC / 50 mA
Auxiliary supply 230 V
Auxiliary supply tolerance 0.9…1.1 Uaux
Power consumption ≤ 6 VA / ≤ 4 W
Installation category III
Pollution degree 2
Insulation reference voltage 300 V
EMC According to EN / IEC 61326-2-4
Operating temperature -5…55 °C
Storage temperature -25…70 °C
Climatic suitability Suitable for tropical climates
Mounting Snap-on mounting on 35 mm DIN rail
Rail type TH35-15 according to EN / IEC 60715
Connection Screw terminals for cable up to 4 mm²
Housing material Self-extinguishing Makrolon
Protection degree IP54 front frame, IP20 terminals
Weight 285 g






Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    RIH – Insulation monitoring

    • Insulation monitor for medical locations and hospital use
    • Continuous monitoring of insulation towards earth in medical IT systems
    • Suitable for operation with Iso TV insulation transformer
    • Monitoring of insulation values, transformer temperature, current, voltage, frequency and power
    • Programmable alarm and pre-alarm thresholds for insulation, temperature and power
    • LCD display with 7 measurement pages and LED alarm indications
    • RS485 communication, JBUS / MODBUS compatible
    • 4-DIN-module housing for 35 mm DIN rail mounting with IP54 front frame
    Datasheet

    Iso D4-Zs

    Insulation monitor for hospital use, 4 DIN modules

    Type Insulation monitor for medical locations and hospital use
    Format 4 DIN modules according to DIN 43880
    Application Continuous monitoring of insulation towards earth in medical IT systems
    Reference standards EN / IEC 61557-8, Attachment A and B; field of application IEC 60364-7-710
    Connection Insulation transformer Iso TV, NT699
    Network voltage 230 V
    Rated frequency 50 Hz
    Working frequency 47…63 Hz
    Insulation measuring circuit current ≤ 100 µA
    Temperature sensor Pt100, 2-wire resistance bulb
    Current input Via CT / 5 A current transformer
    Rated burden current input ≤ 0.5 VA
    Input impedance > 100 kΩ
    Measuring voltage < 15 V
    Display LCD, 2 lines × 8 digits, digit height 5 mm
    Measurement display 7 display pages for insulation values, transformer temperature, voltage, frequency, current, active and apparent power
    Programmable parameters CT ratio, transformer power, measurement quantity, alarm and pre-alarm values, hysteresis, delay and RS485 parameters
    Selectable transformer power 1.5 / 2.5 / 3 / 4 / 5 / 6.3 / 7.5 / 8 / 10 kVA
    Insulation alarm 50…500 kΩ
    Insulation pre-alarm Alarm…500 kΩ
    Temperature alarm 60…150 °C
    Power alarm 50…100 % Pn
    Alarm hysteresis 0…99 %
    Alarm delay 0…99 s
    RS485 communication RS485, 3-wire, serial asynchronous, JBUS / MODBUS compatible
    RS485 address 1…255
    Baud rate 1,200 / 2,400 / 4,800 / 9,600 / 19,200 bit/s
    Max. bus length 1200 m
    Max. devices on the bus 32, up to 255 with RS485 repeater
    Outputs Insulation alarm, temperature / power alarm and output for Iso QZ remote repeater panel
    Contact rating alarm outputs 230 VAC / 50 mA
    Auxiliary supply 230 V
    Auxiliary supply tolerance 0.9…1.1 Uaux
    Power consumption ≤ 6 VA / ≤ 4 W
    Installation category III
    Pollution degree 2
    Insulation reference voltage 300 V
    EMC According to EN / IEC 61326-2-4
    Operating temperature -5…55 °C
    Storage temperature -25…70 °C
    Climatic suitability Suitable for tropical climates
    Mounting Snap-on mounting on 35 mm DIN rail
    Rail type TH35-15 according to EN / IEC 60715
    Connection Screw terminals for cable up to 4 mm²
    Housing material Self-extinguishing Makrolon
    Protection degree IP54 front frame, IP20 terminals
    Weight 285 g